Szymon Saternus

Mr. Szymon Saternus

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2024 in Materials
Verified
Journal Article
Open access
PDF file
AKAnna Ewa Kuc
Anna Ewa Kuc
Kamil SybilskiKamil Sybilski
Kamil Sybilski
JKJacek Kotuła
Jacek Kotuła
GPGrzegorz Piątkowski
Grzegorz Piątkowski
BKBeata Kawala
Beata Kawala
MSMichal Sarul
Michal Sarul
Excessive orthodontic force can induce inflammatory tooth root resorption due to sustained high stresses within the periodontal ligament (PDL). This study aimed to analyze the PDL pressures during upper incisor retraction using the en masse method with TISAD. The finite element method (FEM) ensured consistent conditions across cases. The models included bone geometry, adjacent teeth, PDL, and orthodontic hardware, analyzed with LS-Dyna. The pressure ranged from 0.37 to 2.5 kPa across the dental arch, with the central incisors bearing 55% of the load. The pressure distribution remained consistent regardless of the force or hook height. The critical pressure (4.7 kPa) was exceeded at 600–650 g force, with notable pressure (3.88 kPa) on the palatal root wall of the right central incisor. Utilizing 0.017 × 0.025 SS archwires in MBT 0.018 brackets provided good torque control and reduced the root resorption risk when forces of 180–200 g per side were applied, maintaining light to moderate stress. Triple forces may initiate resorption, highlighting the importance of nonlinear finite element analysis (FEA) for accurate oral cavity simulations.

Verified
Journal Article
Open access
PDF file
AKAnna Ewa Kuc
Anna Ewa Kuc
JKJacek Kotuła
Jacek Kotuła
Kamil SybilskiKamil Sybilski
Kamil Sybilski
Szymon SaternusSzymon Saternus
Szymon Saternus
Jerzy MałachowskiJerzy Małachowski
Jerzy Małachowski
MSMagdalena Ewa Sulewska
Magdalena Ewa Sulewska
Background: Adult patients with a thin buccal cortical plate and fragile periodontal phenotype are at high risk of dehiscence, fenestration and recession during transverse orthodontic expansion. Conventional mechanics often create a cervical compression-dominant environment that exceeds the adaptive capacity of the periodontal ligament (PDL)–bone complex. Objectives: This study proposes an integrative mechanobiological model in which a skeletal-anchorage-assisted loading protocol (Bone Protection System, BPS) transforms expansion into a tension-dominant regime that favours buccal phenotype preservation. Methods: Patient-specific finite element models were used to compare conventional expansion with a BPS-modified force system. Regional PDL stress patterns and crown/apex displacement vectors were analysed to distinguish tipping-dominant from translation-dominated mechanics. A pilot CBCT proof-of-concept (n = 1 thin-phenotype adult) with voxel-based registration quantified changes in maxillary and mandibular alveolar ridge width and buccal cortical plate thickness before and after BPS-assisted expansion. The mechanical findings were integrated with current evidence on compression- versus tension-driven inflammatory and osteogenic pathways in the PDL and cortical bone. Results: FEM demonstrated that conventional expansion concentrates high cervical compressive stress along the buccal PDL and cortical surface, accompanied by bending-like crown–root divergence. In contrast, the BPS protocol redirected forces to create a buccal tensile-favourable region and a more parallel crown–apex displacement pattern, indicative of translation-dominated movement. In the proof-of-concept (n = 1) CBCT case, BPS-assisted expansion was associated with preservation or increase of buccal ridge dimensions without radiographic signs of cortical breakdown. Conclusions: A tension-dominant orthodontic loading environment generated by a skeletal-anchorage-assisted force system may support buccal cortical preservation and vestibular phenotype reinforcement in thin-phenotype patients. The proposed mechanobiological model links these imaging and FEM findings to known molecular pathways of inflammation, angiogenesis and osteogenesis. It suggests a functional biomaterial-based strategy for widening the biological envelope of safe tooth movement.

14 January 2026 in Biomolecules
Verified
Journal Article
Open access
PDF file
AKAnna Ewa Kuc
Anna Ewa Kuc
MSMagdalena Ewa Sulewska
Magdalena Ewa Sulewska
Kamil SybilskiKamil Sybilski
Kamil Sybilski
JKJacek Kotuła
Jacek Kotuła
GHGrzegorz Hajduk
Grzegorz Hajduk
MSMichal Sarul
Michal Sarul
Background: Mechanical loading is a fundamental regulator of bone remodelling; however, the mechanotransduction mechanisms governing alveolar bone adaptation under tensile-dominant orthodontic loading remain insufficiently defined. In particular, the molecular pathways associated with tension-driven cortical modelling in the periodontal ligament (PDL)–bone complex have not been systematically interpreted in the context of advanced biomechanical simulations. Methods: A nonlinear finite element model of the alveolar bone–PDL–tooth complex was developed using patient-specific CBCT data. Three loading configurations were analysed: (i) conventional orthodontic loading, (ii) loading combined with corticotomy alone, and (iii) a translation-dominant configuration generated by the Bone Protection System (BPS). Pressure distribution, displacement vectors, and stress polarity within the PDL and cortical plate were quantified across different bone density conditions. The mechanical outputs were subsequently interpreted in relation to established mechanotransductive molecular pathways involved in osteogenesis and angiogenesis. Results: Conventional loading generated compression-dominant stress fields within the marginal PDL, frequently exceeding physiological thresholds and producing moment-driven root displacement. Corticotomy alone reduced local stiffness but did not substantially alter stress polarity. The BPS configuration redirected loads toward a tensile-favourable mechanical environment characterised by reduced peak compressive pressures and parallel (translation-dominant) displacement vectors. The predicted tensile stress distribution is compatible with activation profiles of key mechanosensitive pathways, including integrin–FAK signalling, Wnt/β-catenin–mediated osteogenic differentiation and HIF-1α/VEGF-driven angiogenic coupling, suggesting a microenvironment that may be more conducive to cortical apposition than to resorption. Conclusions: This study presents a computational–molecular framework linking finite element–derived tensile stress patterns with osteogenic and angiogenic signalling pathways relevant to alveolar bone remodelling. The findings suggestthat controlled redirection of orthodontic loading toward tensile domains may shift the mechanical environment of the PDL–bone complex toward conditions associated with osteogenic than resorptive responses providing a mechanistic basis for tension-induced cortical modelling. This mechanobiological paradigm advances the understanding of load-guided alveolar bone adaptation at both the tissue and molecular levels.

24 November 2025 in Materials
Verified
Journal Article
Open access
PDF file
AKAnna Ewa Kuc
Anna Ewa Kuc
Kamil SybilskiKamil Sybilski
Kamil Sybilski
JKJacek Kotuła
Jacek Kotuła
GHGrzegorz Hajduk
Grzegorz Hajduk
MSMagdalena Ewa Sulewska
Magdalena Ewa Sulewska
MSMichal Sarul
Michal Sarul
Introduction: The aim of this study was to evaluate the effect of corticotomy incision depth on tooth movement and stress distribution in the periodontal ligament (PDL) during orthodontic expansion using finite element analysis (FEA). The demand for accelerated and biologically safe orthodontic techniques has highlighted the importance of understanding biomechanical responses to surgical adjuncts like corticotomy. Objective: The aim of this study is to assess the effect of corticotomy depth on tooth movement and periodontal ligament stress distribution during orthodontic treatment using finite element analysis. Materials and methods: A 3D FEM model was developed based on CBCT and intraoral scans to replicate anatomical structures and simulate clinical orthodontic scenarios. Four conditions were analyzed: no corticotomy and corticotomy incisions of 1 mm, 2 mm, and 3 mm depths, applied between roots and above the apex region. Different cortical bone densities were tested using Young’s modulus values (12,500 MPa–27,500 MPa). Stress and displacement values were measured in both the crown and root regions. Results: The 3 mm corticotomy, penetrating through the cortical plate into the cancellous bone, significantly increased crown displacement (up to 26% in low-density bone) and altered root tipping patterns, reducing root movement relative to the crown. Shallower incisions (1–2 mm) had minimal effects. Despite increased movement, stress concentration in the cervical PDL region remained high across all scenarios, particularly in the premolar area, exceeding the 4.7 kPa threshold associated with tissue ischemia. Conclusions: Corticotomy depth is a critical factor for optimizing orthodontic tooth movement. Penetration into cancellous bone (3 mm) appears necessary to induce both: not only the Regional Acceleratory Phenomenon (RAP) but also to enhance displacement. However, this approach does not significantly reduce cervical PDL stress and offers limited periodontal protection. Individual planning based on bone density, morphology, and anatomical limitations is essential for balancing treatment efficiency and periodontal safety.

14 August 2025 in Acta of Bioengineering and Biomechanics
Verified
Journal Article
Closed access
MSMichał Stankiewicz
Michał Stankiewicz
Szymon SaternusSzymon Saternus
Szymon Saternus
Michalina BłażkiewiczMichalina Błażkiewicz
Michalina Błażkiewicz
JSJustyna Satławska
Justyna Satławska
KCKatarzyna Cwyl
Katarzyna Cwyl
AKAleksandra Kłak-Dziemian
Aleksandra Kłak-Dziemian
Purpose: The aim of this study was to compare the biomechanical parameters of runners during overground and treadmill running, to assess the significance of these differences for treadmill training, and to evaluate their relevance for physiotherapy.Methods: Ten professional runners (mean age of 31.2 ± 6.8 years) were evaluated using a 10-camera Vicon motion capture system and a Phantom V12 high-speed camera. After completing a 200-meter overground run at a self-selected pace, each athlete entered the calibrated capture volume, where their running velocity and kinetic data were recorded. The individual mean velocities were then replicated on a treadmill positioned within the same capture space.Results: Treadmill running altered lower limb biomechanics compared to over-ground running. Median step length was 3% longer and markedly less variable on the treadmill than over-ground (p < 0.001). The knee-flexion angle differed by surface and side (p < 0.0001), changes were (1° for left, -2° right) but variability narrowed on the treadmill, while the knee-impact angle remained unchanged. Relative to over-ground running treadmill running reduced the horizontal distance between the center of gravity and foot initial contact; ground-contact time (12%) and heel velocity after toe-off by 19 % (p < 0.0001).Conclusions: Treadmill running alters lower limb biomechanics by reducing ground contact time, heel velocity, and variability in movement patterns. The consistent mechanics observed on the treadmill may support its use in physiotherapy, particularly for hamstring rehabilitation. However, due to limited replication of natural conditions, treadmill training should complement rather than replace overground running.

26 February 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Szymon SaternusSzymon Saternus
Szymon Saternus
MSMichał Stankiewicz
Michał Stankiewicz
Kamil SybilskiKamil Sybilski
Kamil Sybilski
MKMarcin Konarzewski
Marcin Konarzewski
Jerzy MałachowskiJerzy Małachowski
Jerzy Małachowski
RPRafał Pluciński
Rafał Pluciński
The objective of the study was to undertake a preliminary analysis of the operational accuracy of a prototype suspension therapy apparatus. This entailed the establishment of the kinematic relationship between the movements imposed by the actuators and the movements of the participants’ body segments. The experimental procedure involved the taking of measurements on six participants (average age 32 ± 8 years, weight 67 ± 7 kg, height 178 ± 7 cm). Five movement sequences were observed, including rotation of the head, shoulders, and pelvis, and alternating movement of the shoulders, relative to the pelvis, and the head, relative to the shoulders. The movement of body segments and actuators was recorded using a Vicon optoelectronic system, based on passive markers. A virtual kinematic model was prepared for each of the measurements. It was found that the relationship between the actuator-imposed rotations and the resulting segmental rotations depended on the movement sequence and the body segment involved. The mean head rotation was 46.4° ± 1.2° (27.8% greater than the actuator setting) and the mean shoulder rotation was 23.8° ± 2.4° (11.1% greater), whereas the mean pelvic rotation (20.1° ± 0.9°) showed near agreement with the actuator-imposed value. In alternating movement sequences, distinct directional patterns were observed: head rotation remained greater than the actuator setting, shoulder rotation showed near-agreement or moderate increases, and pelvic rotation in the shoulder–pelvis sequence was markedly lower than the actuator-imposed rotation. The device demonstrates a high level of efficacy in mapping movements, particularly with regard to pelvic rotation. Differences in head rotation indicate the need for further optimisation of movement sequences. The results suggest mapping stability for the majority of participants, with isolated deviations requiring further investigation.