Kamil Sybilski

Dr. Kamil Sybilski

Military Academy of Technology, Poland
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in International Journal of Pressure Vessels and Piping
Verified
Journal Article
Closed access
Lukasz Andrzej MazurkiewiczLukasz Andrzej Mazurkiewicz
Lukasz Andrzej Mazurkiewicz
MTMichał Tomaszewski
Michał Tomaszewski
Jerzy MałachowskiJerzy Małachowski
Jerzy Małachowski
Kamil SybilskiKamil Sybilski
Kamil Sybilski
MCMikhail Chebakov
Mikhail Chebakov
RDRoman Dmitrienko
Roman Dmitrienko

24 April 2020 in Materials
Verified
Journal Article
Open access
PDF file
JBJakub Bukala
Jakub Bukala
Paweł BuszmanPaweł Buszman
Paweł Buszman
Jerzy MałachowskiJerzy Małachowski
Jerzy Małachowski
Lukasz Andrzej MazurkiewiczLukasz Andrzej Mazurkiewicz
Lukasz Andrzej Mazurkiewicz
Kamil SybilskiKamil Sybilski
Kamil Sybilski
The use of bioresorbable polymers such as poly(lactic-co-glycolic acid) (PLGA) in coronary stents can hypothetically reduce the risk of complications (e.g., restenosis, thrombosis) after percutaneous coronary intervention. However, there is a need for a constitutive modeling strategy that combines the simplicity of implementation with strain rate dependency. Here, a constitutive modeling methodology for PLGA comprising numerical simulation using a finite element method is presented. First, the methodology and results of PLGA experimental tests are presented, with a focus on tension tests of tubular-type specimens with different strain rates. Subsequently, the constitutive modeling methodology is proposed and described. Material model constants are determined based on the results of the experimental tests. Finally, the developed methodology is validated by experimental and numerical comparisons of stent free compression tests with various compression speeds. The validation results show acceptable correlation in terms of both quality and quantity. The proposed and validated constitutive modeling approach for the bioresorbable polymer provides a useful tool for the design and evaluation of bioresorbable stents.

23 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
NDNatalia Daniel
Natalia Daniel
Kamil SybilskiKamil Sybilski
Kamil Sybilski
Wojciech KaczmarekWojciech Kaczmarek
Wojciech Kaczmarek
DSDariusz Siemiaszko
Dariusz Siemiaszko
Jerzy MałachowskiJerzy Małachowski
Jerzy Małachowski
In the scientific literature focused on surface electromyography (sEMG) and functional near-infrared spectroscopy (fNIRS), which have been described together and separately many times, presenting different possible applications, researchers have explored a diverse range of topics related to these advanced physiological measurement techniques. However, the analysis of the two signals and their interrelationships continues to be a focus of study in both static and dynamic movements. The main purpose of this study was to determine the relationship between signals during dynamic movements. To carry out the analysis described, the authors of this research paper chose two sports exercise protocols: the Astrand–Rhyming Step Test and the Astrand Treadmill Test. In this study, oxygen consumption and muscle activity were recorded from the gastrocnemius muscle of the left leg of five female participants. This study found positive correlations between EMG and fNIRS signals in all participants: 0.343–0.788 (median-Pearson) and 0.192–0.832 (median-Spearman). On the treadmill, the signal correlations between the participants with the most active and least active lifestyle achieved the following medians: 0.788 (Pearson)/0.832 (Spearman) and 0.470 (Pearson)/0.406 (Spearman), respectively. The shapes of the changes in the EMG and fNIRS signals during exercise suggest a mutual relationship during dynamic movements. Furthermore, during the treadmill test, a higher correlation was observed between the EMG and NIRS signals in participants with a more active lifestyle. Due to the sample size, the results should be interpreted with caution.

10 February 2025 in Materials
Verified
Journal Article
Open access
PDF file
AKAnna Ewa Kuc
Anna Ewa Kuc
Kamil SybilskiKamil Sybilski
Kamil Sybilski
MSMichał Stankiewicz
Michał Stankiewicz
JKJacek Kotuła
Jacek Kotuła
NKNatalia Kuc
Natalia Kuc
MSMichal Sarul
Michal Sarul
Background: Hydrostatic pressure in the periodontal ligament (PDL) plays a critical role in orthodontic treatment, influencing tooth movement and remodeling of periodontal tissue. The relationship between alveolar cortical bone density and the risk of root resorption due to excessive stress in the PDL has not been clearly defined. Objective: This study aimed to analyze hydrostatic pressure in the periodontal ligament of the tooth roots during en-masse retraction of the maxillary incisors using temporary skeletal anchorage devices (TISADs) after the first premolar extractions, as well as during full arch retraction. Methods: A numerical model was used, varying the Young’s modulus of cortical bone from 12.5 GPa to 27.5 GPa in increments of 3.0 GPa. Extreme values for bone stiffness were derived from the literature. In all the cases analyzed, the hook height was fixed at 6 mm, and the cranial surface was constrained. Results: Doubling the stiffness of the cortical bone approximately reduced the hydrostatic pressure in the PDL by 1.5 times for both full-arch retraction and post-first premolar extraction retraction. A critical hydrostatic pressure of 4.7 kPa was exceeded in full-arch retraction for low Young’s modulus of 12.5 Gpa values at forces as low as 600 g. On the contrary, for cortical bone with a high Young’s modulus of 27.5 GPa, this critical pressure was reached only at forces around 960 g, approximately 1.6 times higher. Conclusions: The density of the alveolar cortical bone significantly influences the hydrostatic pressure in the PDL of most tooth roots during orthodontic treatment. This parameter can be a critical factor in the risk of root resorption when optimal forces are exceeded. Further research is necessary to better understand these dynamics. Individual protocols for orthodontic treatment and CBCT imaging are necessary to minimize complications in the form of root resorption.

4 February 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Kamil SybilskiKamil Sybilski
Kamil Sybilski
Jerzy MałachowskiJerzy Małachowski
Jerzy Małachowski
Adapting a car for a disable person involves adding additional equipment to compensate for the driver’s disability. During this process, the change in the driver’s position and kinematics and their impact on safety levels during crash is not considered. There is also a lack of studies in the literature on this problem. This paper describes a methodology for conducting a study of the behavior of a disabled driver during a crash using the finite element method, based on an explicit time integration method. A validated car model and a commercial dummy model were used. The results show that the use of a handle on the steering wheel and a hand control unit causes dangerous lateral displacements relative to the seat. Amputation of the left leg or right arm causes significant shoulder rotations, amputation of the left leg causes increased thoracic loads. Amputation or additional equipment have no significant impact on head injuries.

4 April 2024 in Materials
Verified
Journal Article
Open access
PDF file
AKAnna Ewa Kuc
Anna Ewa Kuc
Kamil SybilskiKamil Sybilski
Kamil Sybilski
JKJacek Kotuła
Jacek Kotuła
GPGrzegorz Piątkowski
Grzegorz Piątkowski
BKBeata Kawala
Beata Kawala
MSMichal Sarul
Michal Sarul
Excessive orthodontic force can induce inflammatory tooth root resorption due to sustained high stresses within the periodontal ligament (PDL). This study aimed to analyze the PDL pressures during upper incisor retraction using the en masse method with TISAD. The finite element method (FEM) ensured consistent conditions across cases. The models included bone geometry, adjacent teeth, PDL, and orthodontic hardware, analyzed with LS-Dyna. The pressure ranged from 0.37 to 2.5 kPa across the dental arch, with the central incisors bearing 55% of the load. The pressure distribution remained consistent regardless of the force or hook height. The critical pressure (4.7 kPa) was exceeded at 600–650 g force, with notable pressure (3.88 kPa) on the palatal root wall of the right central incisor. Utilizing 0.017 × 0.025 SS archwires in MBT 0.018 brackets provided good torque control and reduced the root resorption risk when forces of 180–200 g per side were applied, maintaining light to moderate stress. Triple forces may initiate resorption, highlighting the importance of nonlinear finite element analysis (FEA) for accurate oral cavity simulations.