Office occupants spend most of their time in an enclosed indoor environment, controlled by heating, ventilation and air-conditioning (HVAC) systems especially in subtropical regions owing to the hot and humid climate. A reasonable indoor environment evaluation model is necessary to achieve the reliable control of HVAC systems that satisfies the occupants’ health and comfort needs. However, traditional HVAC systems are controlled based on a simple index that does not consider the synthesis of indoor air quality, thermal comfort and occupant preferences. In this paper, we develop a comprehensive evaluation model that encompasses these three aspects based on field survey. Field surveys were conducted to investigate indoor environmental conditions and preferences of the occupants. Collected data were then verified for model hypothesis rationality and reviewed to identify weighting factors using Pearson and regression analysis. Results showed that these parameters had significant correlations without noticeable collinearity and can be integrated using regression method. The weighting factors of each parameter were calculated using occupants’ sensation and expectation to reflect the subjective preferences in model. Finally, an evaluation model expressing the indoor thermal, air quality and occupant preferences was developed to provide an HVAC intelligent control system that is more responsive to occupant needs.
Assessing energy consumption in existing old residential buildings is key for urban energy conservation and decarbonization. Previous studies on old residential building energy assessment face challenges due to data limitations and inadequate prediction methods. This study develops a novel approach integrating building energy simulation and machine learning to predict large-scale old residential building energy use using multi-source datasets. Using Guangzhou as a case study, open-source building data was collected to identify 31,209 old residential buildings based on age thresholds and areas of interest (AOIs). Key building form parameters (i.e., long side, short side, number of floors) were then classified to identify residential archetypes. Building energy consumption data for each prototype was generated using EnergyPlus (V23.2.0) simulations. Furthermore, XGBoost and Random Forest machine learning algorithms were used to predict city-scale old residential building energy consumption. Results indicated that five representative prototypes exhibited cooling energy use ranging from 17.32 to 21.05 kWh/m2, while annual electricity consumption ranged from 60.10 to 66.53 kWh/m2. The XGBoost model demonstrated strong predictive performance (R2 = 0.667). SHAP (Shapley Additive Explanations) analysis identified the Building Shape Coefficient (BSC) as the most significant positive predictor of energy consumption (SHAP value = 0.79). This framework enables city-level energy assessment for old residential buildings, providing critical support for retrofitting strategies in sustainable urban renewal planning.
Building anthropogenic heat emission is one of the key factors contributing to both building thermal environment and urban heat island, which can potentially lead to increasement of building energy consumption and carbon emission. Mitigating this heat through green belts is an effective solution to achieving low carbon development in buildings. Therefore, this study analyzed the impact of the location and type of green belts around buildings on the thermal environment around buildings. A co-benefit assessment model was developed to quantify green belt design parameters based on the identification of optimal green belt types and locations. Results showed the building thermal environment was significantly influenced by anthropogenic heat emission, leading to a maximum increase of 3.4°C in air temperature. Compared with buildings without green belts, the optimal green belt design (i.e. lawns, shrubs and trees configuration) could decrease the temperature around the building by 1.85°C, while the cooling efficiency reached 47.20%. The optimal lawn area distance was determined to be 0.5 S (S is the building’s footprint), the optimal shrub length was found at 0.6 L to 0.8 L (L is the length of the building), while the optimal tree spacing distance was determined to be 3.5 m to 4.0 m in this study.
1 September 2019 in IOP Conference Series: Materials Science and Engineering
Control of heating, ventilation and air-conditioning systems (HVAC) has become an active area of research due to the significant energy expenditures and maintenance cost. Among the various controls of HVAC systems, chiller sequencing control is of great importance for multi-chiller plant to keep cooling reliability, system stability and energy efficiency. However, conventional chiller sequencing control usually lacks consideration of system stability and the accessional cost caused by the sequencing actions. Especially, those short-time or unnecessary sequencing actions become the main reason for operators to shut down automatic control. To enhance the reliability of chiller sequencing control, a robust hybrid predictive control is developed. This control is developed based on the typical total cooling load-based control and use an ARX prediction model to double check necessity of the sequencing actions. Case studies were carried out on a TRNSYS dynamic simulation with the configuration data from a real secondary school. Results showed that the switch number can be reduced more than 20% and operation cost can be reduced up to 4.25% without scarified in thermal comfort and energy efficiency.