Yongbo Cui

Yongbo Cui

Auto-generated profile, based on publicly available information

Yongbo Cui

Guangzhou University

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2024 in Indoor and Built Environment
Verified
Journal Article
Closed access
YCYongbo Cui
Yongbo Cui
Chengliang FanChengliang Fan
Chengliang Fan
XZXiaoqing Zhou
Xiaoqing Zhou
LLLi Li
Li Li
Maintaining regular physical exercise is essential for maintaining good health. In China, fitness centres are thriving, and the cleanliness of the exercise environment has become increasingly important. This study investigated the thermal response and indoor air environment of fitness personnel in various areas of a fitness centre using subjective evaluation and on-site air environment measurements. The findings revealed that the indoor air environment in different exercise areas of the fitness centre varied spatially, which can lead to discomfort amongst fitness personnel during exercise. Overall, the thermal sensation in different areas of the fitness centre was found consistently too hot. Temperature and humidity have the greatest impact on the thermal sensation of individuals in different areas, while indoor air pollutants have a minimal effect. The intensity and duration of exercise can also influence the body’s heat sensation and pollutant inhalation dose. The body’s heat balance mechanism can affect subjective evaluations. This study proposes three strategies for optimizing the indoor environment of fitness centres through principal component analysis. This paper provides data and a methodological framework for the development of specifications supporting the design, operation and management of the environment in fitness centres.

22 November 2024 in Indoor and Built Environment
Verified
Journal Article
Closed access
YCYongbo Cui
Yongbo Cui
Chengliang FanChengliang Fan
Chengliang Fan
XZXiaoqing Zhou
Xiaoqing Zhou
Yundan LiaoYundan Liao
Yundan Liao
Building anthropogenic heat emission is one of the key factors contributing to both building thermal environment and urban heat island, which can potentially lead to increasement of building energy consumption and carbon emission. Mitigating this heat through green belts is an effective solution to achieving low carbon development in buildings. Therefore, this study analyzed the impact of the location and type of green belts around buildings on the thermal environment around buildings. A co-benefit assessment model was developed to quantify green belt design parameters based on the identification of optimal green belt types and locations. Results showed the building thermal environment was significantly influenced by anthropogenic heat emission, leading to a maximum increase of 3.4°C in air temperature. Compared with buildings without green belts, the optimal green belt design (i.e. lawns, shrubs and trees configuration) could decrease the temperature around the building by 1.85°C, while the cooling efficiency reached 47.20%. The optimal lawn area distance was determined to be 0.5 S (S is the building’s footprint), the optimal shrub length was found at 0.6 L to 0.8 L (L is the length of the building), while the optimal tree spacing distance was determined to be 3.5 m to 4.0 m in this study.

18 July 2026 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
LYLifei Ye
Lifei Ye
ZLZhengguang Liu
Zhengguang Liu
GZGuangpeng Zhang
Guangpeng Zhang
DCDong Chen
Dong Chen
YCYongbo Cui
Yongbo Cui
Soteris KalogirouSoteris Kalogirou
Soteris Kalogirou

31 January 2025 in Environmental Geochemistry and Health
Verified
Journal Article
Closed access
PDF file
YCYongbo Cui
Yongbo Cui
Chengliang FanChengliang Fan
Chengliang Fan
XZXiaoqing Zhou
Xiaoqing Zhou

21 August 2025 in Indoor and Built Environment
Verified
Journal Article
Closed access
XZXiang Zhu
Xiang Zhu
XZXiaoqing Zhou
Xiaoqing Zhou
YCYongbo Cui
Yongbo Cui
Chengliang FanChengliang Fan
Chengliang Fan
The increasing frequency and severity of heat events driven by global warming highlight the need to assess the thermal resilience of buildings under normal operating conditions. The indoor overheating degree (IOD) is a widely adopted metric for quantifying thermal performance. However, its applicability to diverse building thermal resilience assessments is limited due to a lack of relevant data. To address this, this study introduced an improved IOD model that integrates weather conditions and building parameters for the evaluation of indoor thermal performance. The model’s effectiveness was demonstrated through a case study of a residential building in Guangzhou, China. In this study, the most influential factor on the IOD was the outdoor temperature, followed by solar radiation transmittance, the heat transfer coefficient of wall and window, lastly the indoor heat dissipation values. The results showed that by reducing the heat transfer coefficients of walls and windows by 80% and the solar radiation transmittance by 66.7% have yielded IOD reductions of 12.5%, 13.5% and 30.8%, respectively. This study presents an improved IOD model for assessing building thermal resilience, leveraging readily available climatic and building parameter data. It offers a scalable framework for supporting the design of adaptive strategies.

28 February 2024 in Indoor and Built Environment
Verified
Journal Article
Closed access
XLXinru Liu
Xinru Liu
LBLi Bai
Li Bai
YCYongbo Cui
Yongbo Cui
XXXiuling Xu
Xiuling Xu
The Chinese Lunar New Year is a significant festival in China that leads to indoor and outdoor air pollution with distinct characteristics compared to normal times. In this study, indoor and outdoor air samples were collected and analysed to investigate the indoor and outdoor pollution of PM2.5 and its metal elements during the Chinese New Year. The findings reveal that there is a notable positive correlation between indoor and outdoor PM2.5 concentrations during the Chinese New Year, with outdoor concentrations being higher on average. The levels of PM2.5 concentrations indoors and outdoors started to increase on Chinese New Year’s Eve and peaked after the early hours of the Chinese New Year. The total concentrations of six metal elements (Cd, Cr, Ni, Cu, Pb and Zn) in indoor and outdoor PM2.5 during the Chinese New Year in 2022 were 738.73 ± 134.93 mg/kg and 1124.38 ± 553.14 mg/kg, respectively. Principal component analysis suggests that the main sources of indoor metal elements were from outdoor combustion sources and human activities, while outdoor sources were fireworks displays and emissions from coal combustion. Based on the U.S. EPA risk assessment carried out, both indoor and outdoor PM2.5 metal elements could pose a carcinogenic risk to adults.