Piotr Chodór

Dr. Piotr Chodór

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications


31 October 2017 in Cardiology Journal
Verified
Journal Article
Closed access
PCPiotr Chodór
Piotr Chodór
KWKrzysztof Wilczek
Krzysztof Wilczek
RPRoman Przybylski
Roman Przybylski
JGJan Głowacki
Jan Głowacki
TKTomasz Kukulski
Tomasz Kukulski
ZKZbigniew Kalarus
Zbigniew Kalarus
Background: Paravalvular leak (PVL) has significant impact on long-term outcomes in patients after transcatheter aortic valve implantation (TAVI). This study sought to determine whether multi-slice computed tomography (MSCT)-guided valve selection reduces PVL after CoreValve implantation. Methods: The analysis encompassed 69 patients implanted with CoreValve and were divided into two groups. In Group I (30 patients), valve selection was based on standard procedures, in Group II (39 patients), on MSCT measurements. Paravalvular leak was assessed with angiography and echocardiography. Results: Multi-slice computed tomography results influenced a change of decision as to the size of the implanted valve in 12 (30.9%) patients in Group II and would have caused the decision to change in 9 (37.5%) patients in Group I. The degree of oversizing in Group I and II was 12.8% ± ± 7.6% vs. 18.6% ± 5.1% (p = 0.0006), respectively. The oversizing among the patients with leak degree of 0–1 and ≥ 2 was 18.1% ± 6.0% and 12.8% ± 7.4% (p = 0.0036). Angiographic assessment indicated post-procedural PVL ≥ 2 in 50% of patients in Group I and 20.5% in Group II (p = 0.01), while echocardiographic assessment indicated the same in 73.3% of patients in Group I and 45.6% in Group II (p = 0.0136). The composite endpoint occurred in 26.6% (8/30) patients in Group I vs. 5.1% (2/39) patients in Group II (p = 0.0118). Conclusions: Selecting the CoreValve device based on MSCT resulted in smaller rates of PVL and less frequent composite endpoint. In 1/3 of patients MSCT led to a change of the valve size. The degree of oversizing had a significant impact on PVL.

1 March 2016 in Coronary Artery Disease
Verified
Journal Article
Closed access
MHMichał Hawranek
Michał Hawranek
PDPiotr Desperak
Piotr Desperak
ACAneta Ciślak
Aneta Ciślak
PGPaweł Gąsior
Paweł Gąsior
MGMarek Gierlotka
Marek Gierlotka
MGMariusz Gąsior
Mariusz Gąsior
Second-generation drug-eluting stents (DESs) have shown higher safety and efficacy compared with first-generation DESs. This effect was achieved by improving biocompatibility using an interalia cobalt-chromium construction, thinner stent struts and biodegradable polymers.To assess clinical and angiographic outcomes of patients receiving a novel second-generation cobalt-chromium sirolimus-eluting stent.A total of 424 consecutive patients who received an Alex stent were enrolled in the registry from January to December 2012. The primary outcome measure was the occurrence of 12-month major cardiac adverse events, defined as cases of death, nonfatal myocardial infarction and target lesion revascularization. Quantitative coronary angiography for 240 randomly selected patients was performed by an independent Corelab.The primary endpoint occurred in 31 of 424 patients (7.3%). The rates of death, nonfatal myocardial infarction and target lesion revascularization were 3.3, 2.6 and 3.5%, respectively. According to the definition established by the Academic Research Foundation, definitive and probable stent thrombosis (ST) occurred in 1.6% (7/424) of patients, including six cases of early ST and one case of late ST. The acute device success rate was 98.5%.The ALEX Registry provides evidence for the safety and effectiveness of the study device in a relevant population. Quantitative analysis showed a satisfactory performance of the study device for complex coronary lesions. The 12-month rates of major cardiac adverse event and ST were similar to those of other second-generation DES registries.

1 October 2010
Verified
Journal Article
Closed access
PCPiotr Chodór
Piotr Chodór
KWKrzysztof Wilczek
Krzysztof Wilczek
RPRomuald Przybylski
Romuald Przybylski
MKMarcin Krasoń
Marcin Krasoń
JGJan Głowacki
Jan Głowacki
MZMarian Zembala
Marian Zembala

14 April 2017 in Cardiology Journal
Verified
Journal Article
Open access
PCPiotr Chodór
Piotr Chodór
KWKrzysztof Wilczek
Krzysztof Wilczek
TZTeresa Zielińska
Teresa Zielińska
RPRoman Przybylski
Roman Przybylski
JGJan Głowacki
Jan Głowacki
ZKZbigniew Kalarus
Zbigniew Kalarus
Transcatheter aortic valve implantation (TAVI) is presently a recognized treatment mo-dality for patients with severe aortic stenosis ineligible for surgery. It reduces mortality as compared to the conservative treatment. It is further expected from this therapy to improve quality of life by improving of the cardiovascular function performance. The aim of this study is to compare patients' cardiovascular system efficiency in the 6-minute walk test (6MWT) made before and after TAVI and at the 6-12-month follow-up. From January 2009 until February 2012, in the Silesian Center for Heart Diseases in Zabrze, TAVI was performed in 104 patients. Eighty-two patients who underwent 6MWT before surgery were qualified for the analysis. The average age of the patients was 76.0 ± 9.17 years, women made 45.1%. The risk of surgical treatment according to the Logistic Euroscore averaged 22.76 ± 12.63%, and by the Society of Thoracic Surgeons - 5.55 ± 3.34%. The 6MWT was performed within 1 month before the TAVI procedure, up to a month after the procedure and during the 6-12-month follow-up. The 6-minute walk test after TAVI was performed by 64 patients, and after 6-12 month follow-up by 46 patients. The average distance in 6MWT increased from 268.4 ± 89.0 m before treat-ment to 290.0 ± 98.2 m after the procedure (p = 0.008) and 276.1 ± 93.5 m to 343.1 ± 96.7 m after 6-12 months (p < 0.0001). Transcatheter aortic valve implantation procedures significantly improve function of the cardiovascular system evaluated by the 6MWT in 1- and 6-12-month observations. (Cardiol J 2017; 24, 2: 167-175).