Abhilash Krishnamurthy

Mr. Abhilash Krishnamurthy

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
ŠTŠpela Trafela
Špela Trafela
AKAbhilash Krishnamurthy
Abhilash Krishnamurthy
KZKristina Zagar
Kristina Zagar
UKUrska Kavcic
Urska Kavcic
Igor KarlovitsIgor Karlovits
Igor Karlovits
KRKristina Zuzek Rozman
Kristina Zuzek Rozman
Simple, low-cost methods for sensing volatile organic compounds that leave no trace and do not have a detrimental effect on the environment are able to protect communities from the impacts of contaminants in water supplies. This paper reports the development of a portable, autonomous, Internet of Things (IoT) electrochemical sensor for detecting formaldehyde in tap water. The sensor is assembled from electronics, i.e., a custom-designed sensor platform and developed HCHO detection system based on Ni(OH)2–Ni nanowires (NWs) and synthetic-paper-based, screen-printed electrodes (pSPEs). The sensor platform, consisting of the IoT technology, a Wi-Fi communication system, and a miniaturized potentiostat can be easily connected to the Ni(OH)2–Ni NWs and pSPEs via a three-terminal electrode. The custom-made sensor, which has a detection capability of 0.8 µM/24 ppb, was tested for an amperometric determination of the HCHO in deionized (DI) and tap-water-based alkaline electrolytes. This promising concept of an electrochemical IoT sensor that is easy to operate, rapid, and affordable (it is considerably cheaper than any lab-grade potentiostat) could lead to the straightforward detection of HCHO in tap water.

10 May 2024 in Electrochimica Acta
Verified
Journal Article
Open access
AKAbhilash Krishnamurthy
Abhilash Krishnamurthy
ZSZoran Samardžija
Zoran Samardžija
ŠTŠpela Trafela
Špela Trafela
AKAnja Korent
Anja Korent
SŠSašo Šturm
Sašo Šturm
KSKristina Žagar Soderžnik
Kristina Žagar Soderžnik

29 July 2024 in Sensors
Verified
Journal Article
Open access
PDF file
AKAbhilash Krishnamurthy
Abhilash Krishnamurthy
KZKristina Zagar
Kristina Zagar
We describe two operating modes for the same potentiostat, where the redox processes of hydroquinone in a hydrochloric acid medium are contrasted for cyclic voltammetry (CV) as functions of a digital/staircase scan and an analogue/linear scan. Although superficially there is not much to separate the two modes of operation as an end user, differences can be seen in the voltammograms while switching between the digital and analogue modes. The effects of quantization clearly have some impact on the measurements, with the outputs between the two modes being a function of the equivalent-circuit model of the electrochemical system under investigation. Increasing scan rates when using both modes produces higher peak redox currents, with the differences between the analogue and digital modes of operation being consistent as a function of the scan rate. Differences between the CV loops between the analogue and digital modes show key differences at certain points along the scans, which can be attributed to the nature of the electrolyte affecting the charging and discharging processes and consequently changing the peak currents of the redox processes. The faradaic processes were shown to be independent of the scan rates. Simulations of the equivalent-circuit behaviour show differences in the responses to different input signals, i.e., the step and ramp responses of the system. Both the voltage and current steps and ramp responses showed the time-domain behaviour of distinct elements of the equivalent electrochemical circuit model as an approximation of the applied digital and analogue CV input signals. Ultimately, it was concluded that similar parameters between the two modes of operation available with the potentiostat would lead to different output voltammograms and, despite advances in technology, digital systems can never fully emulate a true analogue system for electrochemical applications. These observations showcase the value of having hardware capable of true analogue characteristics over digital systems.

15 November 2025 in Measurement
Verified
Journal Article
Open access
AKAbhilash Krishnamurthy
Abhilash Krishnamurthy
KSKristina Žagar Soderžnik
Kristina Žagar Soderžnik

26 May 2025 in Metallurgical & Materials Engineering Congress of South-East Europe
Verified
Journal Article
Closed access
Jelena D. VujancevicJelena D. Vujancevic
Jelena D. Vujancevic
NSNeža Sodnik
Neža Sodnik
AKAbhilash Krishnamurthy
Abhilash Krishnamurthy
ZSZoran Samardžija
Zoran Samardžija
KZKristina Zagar
Kristina Zagar
Persistent, mobile, and toxic (PMT) chemicals pose a significant risk to water resources due to their resistance to biodegradation, ability to spread over long distances, and harmful effects on human health and the environment. Among the most widely detected PMT chemicals are bisphenols, benzisothiazolinone (BIT), and benzotriazole (BZT), which originate from common consumer and industrial products. Monitoring these chemicals is essential for assessing their impact and developing strategies for their reduction. Traditional detection methods like chromatography are effective but costly and time-consuming. Electrochemical sensors offer a promising alternative due to their affordability, portability, and high sensitivity. This study used carbon-based screen-printed electrodes (SPEs) to detect BPS and BIT, while SPEs modified with Vulcan carbon and polymer coatings were employed for BZT detection. Real samples, including parking ticket paper and river water, were analyzed to demonstrate the sensors' practical application. The findings highlight the potential of electrochemical sensors as efficient tools for on-site monitoring of PMT chmicals, contributing to improved environmental assessment and regulatory efforts.