David M. Spranz

Dr. David M. Spranz

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2015 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
MMMichael W. Maier
Michael W. Maier
SLSarah Lauer
Sarah Lauer
MKMatthias C. Klotz
Matthias C. Klotz
MBMatthias Bülhoff
Matthias Bülhoff
DSDavid M. Spranz
David M. Spranz
FZFelix Zeifang
Felix Zeifang
Conventional stemmed anatomical shoulder prostheses are widely used in the treatment of glenohumeral osteoarthritis. The stemless shoulder prosthesis, in contrast, is a new concept, and fewer outcome studies are available. Therefore, the purpose of the study was to investigate the early functional outcome and postoperative proprioception of a stemless prosthesis in comparison with a standard stemmed anatomic shoulder prosthesis. Twelve patients (mean age 68.3 years [SD ± 5.4]; 5 female, 7 male) with primary glenohumeral osteoarthritis of the shoulder were enrolled, who underwent total shoulder arthroplasty (TSA) with a stemless total shoulder prosthesis, Total Evolution Shoulder System (TESS®; Biomed, France). The control group consisted of twelve (age and gender matched) patients (mean age 67.8 years; [SD ± 7.1]; 9 female, 3 male), getting a TSA with a standard anatomic stemmed prosthesis, Aequalis® Shoulder (Tournier, Lyon, France). Patients were examined the day before and six months after surgery. The pre- and postoperative Constant Score (CS) was evaluated and proprioception was measured in a 3D video motion analysis study using an active angle-reproduction (AAR) test. Comparing the postoperative CS, there was no significant difference between the groups treated with the TESS® prosthesis (48.0 ± 13.8 points) and the Aequalis® prosthesis (49.3 ± 8.6 points; p = 0.792). There was no significant difference in postoperative proprioception between the TESS® group (7.2° [SD ± 2.8]) and the Aequalis® group(8.7° [SD ± 2.7]; p = 0.196), either. Comparison of in the results of CS and AAR test pre- and postoperatively showed no significant differences between the groups. In patients with glenohumeral osteoarthritis, treated with TSA, the functional and the proprioceptive outcome is comparable between a stemless and a standard stemmed anatomic shoulder prosthesis at early followup. Further follow-up is necessary regarding the long-term performance of this prosthesis. Current Controlled Trials DRKS 00007528 . Registered 17 November 2014

21 November 2017 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
DSDavid M. Spranz
David M. Spranz
HBHendrik Bruttel
Hendrik Bruttel
SWSebastian Wolf
Sebastian Wolf
FZFelix Zeifang
Felix Zeifang
MMMichael W. Maier
Michael W. Maier
The aim of this study is to compare the functional midterm outcome of stemless shoulder prostheses with standard anatomical stemmed shoulder prostheses and to show that the STEMLESS results are comparable to the STEMMED with respect to active maximum range of shoulder motion (ROM) and Constant score (CS). Seventeen patients underwent total shoulder arthroplasty (TSA) in 25 shoulder joints. Stemless TSA was performed in 12 shoulder joints (group STEMLESS), third-generation stemmed TSA in 13 shoulder joints (group STEMMED). Functional results were documented using the CS. 3D-motion-analysis using the Heidelberg upper extremity model (HUX) was conducted to measure active maximum (ROM). The group STEMLESS achieved a CS of 67.9 (SD 12.0) points and the group STEMMED of 70.2 (SD 5.8 points) without significant difference between the groups (p = 0.925). The maximum ROM of the group STEMLESS, ascertained by 3-D-motion-analysis, was in forward flexion 125.5° (SD 17.2°), in extension 49.4° (SD 13.8°), in abduction 126.2° (SD 28.5°) and in external rotation 40.3° (SD 13.9°). The maximum ROM of the group STEMMED, also ascertained by 3-D-motion analysis, was in forward flexion 135.0° (SD 16.8°), in extension 47.2° (SD 11.5°), in abduction 136.3° (SD 24.2°) and in external rotation 40.1° (SD 12.2°). The maximum ROM of the STEMLESS group was lower in forward flexion and abduction, higher in extension and almost identical in external rotation. But there was no significant difference (forward flexion p = 0.174, extension p = 0.470, abduction p = 0.345, external rotation p = 0.978). Both types of shoulder prostheses achieve a similar and good active ROM and similar results in CS. DRKS00013166 , retrospectively registered, 11.10.2017

25 August 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
KKKevin-Arno Koch
Kevin-Arno Koch
DSDavid M. Spranz
David M. Spranz
Fabian WesthauserFabian Westhauser
Fabian Westhauser
TBTom Bruckner
Tom Bruckner
BLBurkhard Lehner
Burkhard Lehner
TWTilman Walker
Tilman Walker
(1) Background: In the treatment of periprosthetic joint infection (PJI), the individual host status and previous surgical procedures appear to have a relevant influence on success rates and clinical outcome of knee revision surgery. Current data about the predictive value are limited in this subgroup of patients. (2) Methods: Retrospectively, 107 patients (109 knees) undergoing two-stage exchange knee arthroplasty for PJI using a rotating-hinge design with at least two years follow-up. The cumulative incidence (CI) for different endpoints was estimated with death as competing risk. Univariate and multivariate analyses for potential predictive factors were performed. Patient-related outcome measures (PROMs) for clinical outcome were evaluated. (3) Results: At 8 years, the CI of any revision was 29.6%, and of any reoperation was 38.9%. Significant predictors for risk of re-revision were the Charlson Comorbidity Index (CCI) and the number of previous surgical procedures prior to explanation of the infected implant. The functional and clinical outcome demonstrated acceptable results in the present cohort with a high comorbidity level. (4) Conclusions: A compromised host status and multiple previous surgical procedures were identified as negative predictors for re-revision knee surgery in the treatment of PJI. Reinfection remained the major reason for re-revision. Overall mortality was high.

Verified
Journal Article
Open access
PDF file
TNTimo Albert Nees
Timo Albert Nees
CMChristian Thomas Mueller
Christian Thomas Mueller
MIMoritz M Innmann
Moritz M Innmann
DSDavid M. Spranz
David M. Spranz
Fabian WesthauserFabian Westhauser
Fabian Westhauser
TWTilman Walker
Tilman Walker
Revision total hip arthroplasty (rTHA) presents significant challenges, particularly in patients with severe acetabular bone defects. Traditional treatment options often fall short, leading to the emergence of custom-made 3D-printed acetabular implants. Accurate assessment of implant positioning is crucial for ensuring optimal postoperative outcomes and for providing feedback to the surgical team. This single-center, retrospective cohort study evaluates the accuracy of standard 2D radiographs versus 3D CT scans in assessing the positioning of these implants, aiming to determine if 2D imaging could serve as a viable alternative for the postoperative evaluation. We analyzed the implant positions of seven rTHA patients with severe acetabular defects (Paprosky ≥ Type IIIA) using an alignment technique that integrates postoperative 2D radiographs with preoperative CT plans. Two independent investigators, one inexperienced and one experienced, measured the positioning accuracy with both imaging modalities. Measurements included translational shifts from the preoperatively templated implant position in the craniocaudal (CC), lateromedial (LM), and ventrodorsal (VD) directions, as well as rotational differences in anteversion (AV) and inclination (INCL). The study demonstrated that 2D radiographs, when aligned with preoperative CT data, could accurately assess implant positions with precision nearly comparable to that of 3D CT scans. Observed deviations were 1.4 mm and 2.7 mm in CC and LM directions, respectively, and 3.6° in AV and 0.7° in INCL using 2D imaging, all within clinically acceptable ranges. For 3D CT assessments, mean interobserver variability was up to 0.9 mm for translational shifts and 1.4° for rotation, while for 2D alignment, observer differences were 1.4 mm and 3.2° for translation and rotation, respectively. Comparative analysis of mean results from both investigators, across all dimensions (CC, LM, AV, and INCL) for 2D and 3D matching, showed no significant differences. In conclusion, conventional anteroposterior 2D radiographs of the pelvis can sufficiently determine the positioning of custom-made acetabular implants in rTHA. This suggests that 2D radiography is a viable alternative to 3D CT scans, potentially enhancing the implementation and quality control of advanced implant technologies.

5 February 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
PHPit Hetto
Pit Hetto
DSDavid M. Spranz
David M. Spranz
FZFelix Zeifang
Felix Zeifang
SWSebastian Wolf
Sebastian Wolf
SDStefan van Drongelen
Stefan van Drongelen
BSBoris Sowa
Boris Sowa
Background: Massive irreparable posterosuperior rotator cuff tears may result in the loss of external rotation. Most of the patients with posterosuperior rotator cuff tears suffer from a restriction in their daily life actions. Latissimus dorsi tendon transfer (LDTT) is a method to restore abduction and external rotation in these patients. However, the behavior of the LD after the transfer is not clear yet. Few studies have analyzed the activity of the LD after transfer. The goal of this study was to examine the function of the LD postoperatively in follow-up examinations during activities of daily life (ADLs) and during different movements evaluated by measuring the range of motion (ROM). Methods: We examined 12 patients 4.3 years (1–9 years) after LDTT, using simultaneous 3D motion analysis and surface Electromyography (sEMG) of 12 muscle parts; the opposite, nonaffected side was assessed as a control. The measurement protocol included two standardized movements (exorotation with an adducted arm and exorotation with 90° abduction) as well as two ADLs (combing hair and perineal care). Results: An average of 4.3 years (1–9 years) after LDTT, 9 of the 12 subjects showed EMG activity in the transferred LD during glenohumeral external rotation. During the endorotation phase, either little activity was registered or only the pectoralis major was active. During the ADLs, 6 out of 12 subjects showed EMG activity in the transferred LD while “combing hair”, whereas all subjects showed EMG activity during perineal care. Conclusion: The LD showed partial activity in its new role as an exorotator, but no clear difference was observed between some of the movements as well as in comparison with the healthy shoulder. Further studies will need to be conducted to better differentiate voluntary contractions and co-contractions as well as tension and extension in the muscle.

1 January 2022 in The Knee
Verified
Journal Article
Closed access
DSDavid M. Spranz
David M. Spranz
KKKevin-Arno Koch
Kevin-Arno Koch
TRTobias Reiner
Tobias Reiner
PHPit Hetto
Pit Hetto
TGTobias Gotterbarm
Tobias Gotterbarm
CMChristian Merle
Christian Merle