Efstathios P. Efstathopoulos

Prof. Dr. Efstathios P. Efstathopoulos

2nd Department of Radiology, Medical School, National and Kapodistrian University of Athens, 12462 Athens, Greece
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Theodoros AndroutsakosTheodoros Androutsakos
Theodoros Androutsakos
NNNarjes Nasiri-Ansari
Narjes Nasiri-Ansari
ABAthanasios-Dimitrios Bakasis
Athanasios-Dimitrios Bakasis
Ioannis KyrouIoannis Kyrou
Ioannis Kyrou
Efstathios P. EfstathopoulosEfstathios P. Efstathopoulos
Efstathios P. Efstathopoulos
EKEva Kassi
Eva Kassi
Non-alcoholic fatty liver disease (NAFLD) is an ‘umbrella’ term, comprising a spectrum ranging from benign, liver steatosis to non-alcoholic steatohepatitis, liver fibrosis and eventually cirrhosis and hepatocellular carcinoma. NAFLD has evolved as a major health problem in recent years. Discovering ways to prevent or delay the progression of NAFLD has become a global focus. Lifestyle modifications remain the cornerstone of NAFLD treatment, even though various pharmaceutical interventions are currently under clinical trial. Among them, sodium-glucose co-transporter type-2 inhibitors (SGLT-2i) are emerging as promising agents. Processes regulated by SGLT-2i, such as endoplasmic reticulum (ER) and oxidative stress, low-grade inflammation, autophagy and apoptosis are all implicated in NAFLD pathogenesis. In this review, we summarize the current understanding of the NAFLD pathophysiology, and specifically focus on the potential impact of SGLT-2i in NAFLD development and progression, providing current evidence from in vitro, animal and human studies. Given this evidence, further mechanistic studies would advance our understanding of the exact mechanisms underlying the pathogenesis of NAFLD and the potential beneficial actions of SGLT-2i in the context of NAFLD treatment.

6 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
MKMaria Kaloumenou
Maria Kaloumenou
Evangelos SkotadisEvangelos Skotadis
Evangelos Skotadis
NLNefeli Lagopati
Nefeli Lagopati
Efstathios P. EfstathopoulosEfstathios P. Efstathopoulos
Efstathios P. Efstathopoulos
Dimitris TsoukalasDimitris Tsoukalas
Dimitris Tsoukalas
Early-stage disease diagnosis is of particular importance for effective patient identification as well as their treatment. Lack of patient compliance for the existing diagnostic methods, however, limits prompt diagnosis, rendering the development of non-invasive diagnostic tools mandatory. One of the most promising non-invasive diagnostic methods that has also attracted great research interest during the last years is breath analysis; the method detects gas-analytes such as exhaled volatile organic compounds (VOCs) and inorganic gases that are considered to be important biomarkers for various disease-types. The diagnostic ability of gas-pattern detection using analytical techniques and especially sensors has been widely discussed in the literature; however, the incorporation of novel nanomaterials in sensor-development has also proved to enhance sensor performance, for both selective and cross-reactive applications. The aim of the first part of this review is to provide an up-to-date overview of the main categories of sensors studied for disease diagnosis applications via the detection of exhaled gas-analytes and to highlight the role of nanomaterials. The second and most novel part of this review concentrates on the remarkable applicability of breath analysis in differential diagnosis, phenotyping, and the staging of several disease-types, which are currently amongst the most pressing challenges in the field.

1 January 2011 in British Journal of Radiology
Verified
Journal Article
Closed access
Efstathios P. EfstathopoulosEfstathios P. Efstathopoulos
Efstathios P. Efstathopoulos
IPI Pantos
I Pantos
MAM Andreou
M Andreou
AGA Gkatzis
A Gkatzis
ECE Carinou
E Carinou
EBE Brountzos
E Brountzos
The aim of this study was to determine occupational dose levels in interventional radiology and cardiology procedures. The study covered a sample of 25 procedures and monitored occupational dose for all laboratory personnel. Each individual wore eight thermoluminescent dosemeters next to the eyes, wrists, fingers and legs during each procedure. Radiation protection shields used in each procedure were recorded. The highest doses per procedure were recorded for interventionists at the left wrist (average 485 μSv, maximum 5239 μSv) and left finger (average 324 μSv, maximum 2877 μSv), whereas lower doses were recorded for the legs (average 124 μSv, maximum 1959 μSv) and the eyes (average 64 μSv, maximum 1129 μSv). Doses to the assisting nurses during the intervention were considerably lower; the highest doses were recorded at the wrists (average 26 μSv, maximum 41 μSv) and legs (average 18 μSv, maximum 22 μSv), whereas doses to the eyes were minimal (average 4 μSv, maximum 16 μSv). Occupational doses normalised to kerma area product (KAP) ranged from 11.9 to 117.3 μSv/1000 cGy cm² and KAP was poorly correlated to the interventionists' extremity doses. Calculation of the dose burden for interventionists considering the actual number of procedures performed annually revealed that dose limits for the extremities and the lenses of the eyes were not exceeded. However, there are cases in which high doses have been recorded and this can lead to exceeding the dose limits when bad practices are followed and the radiation protection tools are not properly used.

1 January 2009 in Current Cardiology Reviews
Verified
Journal Article
Open access
IPIoannis Pantos
Ioannis Pantos
GPGeorgios Patatoukas
Georgios Patatoukas
DKDemosthenes Katritsis
Demosthenes Katritsis
Efstathios P. EfstathopoulosEfstathios P. Efstathopoulos
Efstathios P. Efstathopoulos
Interventional cardiology procedures result in substantial patient radiation doses due to prolonged fluoroscopy time and radiographic exposure. The procedures that are most frequently performed are coronary angiography, percutaneous coronary interventions, diagnostic electrophysiology studies and radiofrequency catheter ablation. Patient radiation dose in these procedures can be assessed either by measurements on a series of patients in real clinical practice or measurements using patient-equivalent phantoms. In this article we review the derived doses at non-pediatric patients from 72 relevant studies published during the last 22 years in international scientific literature. Published results indicate that patient radiation doses vary widely among the different interventional cardiology procedures but also among equivalent studies. Discrepancies of the derived results are patient-, procedure-, physician-, and fluoroscopic equipmentrelated. Nevertheless, interventional cardiology procedures can subject patients to considerable radiation doses. Efforts to minimize patient exposure should always be undertaken.

19 December 2017 in Cancers
Verified
Journal Article
Open access
PDF file
Ellas SpyratouEllas Spyratou
Ellas Spyratou
MMMersini Makropoulou
Mersini Makropoulou
Efstathios P. EfstathopoulosEfstathios P. Efstathopoulos
Efstathios P. Efstathopoulos
ALEXANDROS GEORGAKILASALEXANDROS GEORGAKILAS
ALEXANDROS GEORGAKILAS
Lembit SihverLembit Sihver
Lembit Sihver
Many tumor-targeted strategies have been used worldwide to limit the side effects and improve the effectiveness of therapies, such as chemotherapy, radiotherapy (RT), etc. Biophotonic therapy modalities comprise very promising alternative techniques for cancer treatment with minimal invasiveness and side-effects. These modalities use light e.g., laser irradiation in an extracorporeal or intravenous mode to activate photosensitizer agents with selectivity in the target tissue. Photothermal therapy (PTT) is a minimally invasive technique for cancer treatment which uses laser-activated photoabsorbers to convert photon energy into heat sufficient to induce cells destruction via apoptosis, necroptosis and/or necrosis. During the last decade, PTT has attracted an increased interest since the therapy can be combined with customized functionalized nanoparticles (NPs). Recent advances in nanotechnology have given rise to generation of various types of NPs, like gold NPs (AuNPs), designed to act both as radiosensitizers and photothermal sensitizing agents due to their unique optical and electrical properties i.e., functioning in dual mode. Functionalized AuNPS can be employed in combination with non-ionizing and ionizing radiation to significantly improve the efficacy of cancer treatment while at the same time sparing normal tissues. Here, we first provide an overview of the use of NPs for cancer therapy. Then we review many recent advances on the use of gold NPs in PTT, RT and PTT/RT based on different types of AuNPs, irradiation conditions and protocols. We refer to the interaction mechanisms of AuNPs with cancer cells via the effects of non-ionizing and ionizing radiations and we provide recent existing experimental data as a baseline for the design of optimized protocols in PTT, RT and PTT/RT combined treatment.

1 April 2011 in British Journal of Radiology
Verified
Journal Article
Closed access
IPI Pantos
I Pantos
STS Thalassinou
S Thalassinou
SAS Argentos
S Argentos
NKN L Kelekis
N L Kelekis
GPG Panayiotakis
G Panayiotakis
Efstathios P. EfstathopoulosEfstathios P. Efstathopoulos
Efstathios P. Efstathopoulos
CT is a valuable tool in diagnostic radiology but it is also associated with higher patient radiation doses compared with planar radiography. The aim of this article is to review patient dose for the most common types of CT examinations reported during the past 19 years. Reported dosimetric quantities were compared with the European diagnostic reference levels (DRLs). Effective doses were assessed with respect to the publication year and scanner technology (i.e. single-slice vs multislice). Considerable variation of reported values among studies was attributed to variations in both examination protocol and scanner design. Median weighted CT dose index (CTDI(w)) and dose length product (DLP) are below the proposed DRLs; however, for individual studies the DRLs are exceeded. Median reported effective doses for the most frequent CT examinations were: head, 1.9 mSv (0.3-8.2 mSv); chest, 7.5 mSv (0.3-26.0 mSv); abdomen, 7.9 mSv (1.4-31.2 mSv); and pelvis, 7.6 mSv (2.5-36.5 mSv). The introduction of mechanisms for dose reduction resulted in significantly lower patient effective doses for CT examinations of the head, chest and abdomen reported by studies published after 1995. Owing to the limited number of studies reporting patient doses for multislice CT examinations the statistical power to detect differences with single-slice scanners is not yet adequate.