Zhaozhe Deng

Mr. Zhaozhe Deng

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2022 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
HJHefei Jia
Hefei Jia
YDYan Deng
Yan Deng
XHXue Hu
Xue Hu
ZDZhaozhe Deng
Zhaozhe Deng
HXHe Xiangning
He Xiangning
The insulated gate bipolar transistor (IGBT) is one of the most vulnerable components in the modular multilevel converter (MMC). One or more IGBT open-circuit faults may deteriorate the output performance of the MMC, and even destroy the MMC systems. In this paper, a concurrent and direct fault diagnosis method has been proposed. The capacitor voltages are estimated with an amending Kalman Filter (KF). By comparing the measured and estimated value, the corresponding faulty submodule (SM) can be detected directly and quickly. The diagnosis process of SMs is independent of each other, so that all the SMs can be monitored in real time and the diagnosis time will not increase with multiple open-circuit faults occurring. The proposed method can also identify which IGBT has occurred open-circuit fault in the faulty SM and has no special requirement for the modulation method. Additionally, the amending KF has an excellent robustness to the transient process and can overcome the divergence problem, which is applicable in the complex nonlinear MMC system. The effectiveness of the proposed fault diagnosis method is confirmed by simulation in MATLAB/Simulink and experimentation in a single-phase MMC prototype with 8 SMs per arm.

13 December 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZDZhaozhe Deng
Zhaozhe Deng
XLXingliang Liu
Xingliang Liu
QQQi Qiu
Qi Qiu
HJHefei Jia
Hefei Jia
YDYan Deng
Yan Deng
HXHe Xiangning
He Xiangning
Dielectric barrier discharge (DBD) loads and driving converters are widely utilized in low-temperature plasma generation, but their resonant tanks have typical nonlinear characteristics with control issues. The state plane trajectory analysis is used in this article to investigate the resonant behavior of a DBD load. The converter's working principle and state plane modeling are first discussed. The impact of a high-ratio step-up transformer with parasitic capacitance is then explored, and the updated trajectory model is examined. The DBD platform is created to verify the suggested model, and the associated experimental data are provided. The results of the experiment demonstrate that the discharge trajectory is a zone with distinct borders. The trajectory equations can be utilized to calculate the load equivalent capacitance, and the difference in the boundary equivalent capacitance represents the discharge intensity. The pattern of resonant frequency variation with discharge power is given. The impact mechanism of discharge phenomena and resonance characteristics is discussed.

8 December 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
HJHefei Jia
Hefei Jia
ZDZhaozhe Deng
Zhaozhe Deng
JQJinpeng Qu
Jinpeng Qu
YDYan Deng
Yan Deng
Submodule (SM) capacitor is one of the critical components in modular multilevel converter (MMC) and will gradually age with the working time increasing, which brings potential challenges for the systems reliability. This article proposes a novel online capacitance monitoring scheme for SM capacitors. Based on the voltage variations on rising and falling edge of power switches’ operation, the aging capacitors can be monitored in real-time. Meanwhile, the proposed capacitance monitoring scheme is based on the mathematical model of the systems and has good applicability. It has no any impact on the normal operation of the MMC systems, no special requirement for the modulation method and no need for additional hardware circuits. For the proposed capacitance monitoring scheme, it can be implemented in parallel mode or sequential mode based on the field-programmable gate array (FPGA). Finally, simulation in MATLAB/Simulink and experimentation in a single-phase MMC prototype with 8 SMs per arm are built to confirm the effectiveness of the proposed method.

31 October 2023 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
RLRuijie Li
Ruijie Li
JCJunsheng Cheng
Junsheng Cheng
LXLing Xiong
Ling Xiong
ZDZhaozhe Deng
Zhaozhe Deng
HXHe Xiangning
He Xiangning
Qiuliang WangQiuliang Wang
Qiuliang Wang
This article designs a position trigger control system for multistage asynchronous electromagnetic coil launcher. First, the composition and characteristics of position trigger control system are analyzed, and the armature velocity measurement scheme and velocity measurement principle adopted in this article are introduced. According to the delay characteristic of real trigger control system, the armature position prediction model and position trigger control model are established, and the black box control system running rules are summarized; then, the black box control algorithm is realized based on DSP TMS320F28335. Based on the systematic analysis of the main factors affecting the control precision of position trigger control system, the displacement error function is derived and the control precision is expressed quantitatively. Finally, the feasibility of the control system and the results of the control precision analysis are verified by the experimental data analysis.

18 March 2025 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
ZDZhaozhe Deng
Zhaozhe Deng
QQQi Qiu
Qi Qiu
HJHefei Jia
Hefei Jia
WZWenbo Zhu
Wenbo Zhu
YDYan Deng
Yan Deng
HXHe Xiangning
He Xiangning
The low-temperature plasma is a widely used technique for gas treatment, which is typically produced using dielectric barrier discharge (DBD). Considering the randomness of space discharge, adopting a multineedle electrode structure will be more controllable and effective, and its electrical behavior needs to be analyzed in the design of the driving power supply. This article studies the load characteristics of DBD using multineedle coaxial cylindrical electrodes based on the state plane analysis method and points out the variations in power and resonance characteristics under different operating situations. It provides a foundation for the design of discharge arrays and driving power supplies. First, the reactor’s construction and the driving converter’s operation were introduced, and the state plane modeling was done with parasitic capacitance taken into account. Then, a DBD platform was built for experimental verification, depicting the working mode of a single discharge load from multiple perspectives. The difference between the ideal model and the state trajectory of a single discharge load was theoretically analyzed. Finally, comparative experiments on the load characteristics of arrays with varying discharge unit counts were carried out. The connection between power, resonant characteristics, and load scale is shown in the experimental data.

7 August 2024 in Energies
Verified
Journal Article
Open access
PDF file
ZDZhaozhe Deng
Zhaozhe Deng
HQHao Qin
Hao Qin
WZWenbo Zhu
Wenbo Zhu
QQQi Qiu
Qi Qiu
YDYan Deng
Yan Deng
HXHe Xiangning
He Xiangning
Photovoltaic power generation and energy storage technology are current hotspots in the clean energy industry. As a core piece of equipment, an inverter is subjected to higher demands for its voltage regulation range and output performance. A differential boost inverter features a boosting function not found in traditional inverters, effectively widening the input voltage range, with characteristics of a single-stage structure and simple modulation. However, the differential boost inverter faces the issue of high common-mode voltage. Considering that the magnitude of the common-mode voltage changes with different modulation methods, a novel modulation strategy with a flexible common-mode voltage is proposed, which can effectively suppress the common-mode voltage under the same gain without affecting the output power quality. This article first introduces the topology, working principle, and traditional modulation methods of the differential boost inverter. Then, the new modulation strategy is defined, and the gain equation is derived. The new modulation method’s applicable scenarios are discussed and compared to other modulation methods based on the gain curve, concluding that the new method has advantages in terms of common-mode voltage amplitude and power quality under low boost gain. Finally, the effectiveness of the proposed method is verified through simulation and experiments.