Initiation of ac fault may lead to the commutation failure, and the high-voltage direct current (HVDC) system is still confronted with the risk of subsequent commutation failure (SCF) during recovery process prior to the fault clearance. In this paper, the mechanism of subsequent commutation failure is investigated through the analysis of controller response and ac-dc interaction under the symmetrical and asymmetrical faults. According to the modulation theory, a switching function method based on the line-to-line voltages is introduced to depict the voltage transfer characteristics of converters under asymmetrical faults. The early warning criterion and its corresponding early warning system for the subsequent commutation failure (SCF-EWS) are developed by taking the risks of controller regulation and the variations of electrical quantities into account. For the purpose of suppression, an emergency advance control strategy against the subsequent commutation failure (SCF-EAC) is also presented. The analysis and the proposed schemes are verified by the CIGRE benchmark model that is shipped with the PSCAD/EMTDC software under different fault conditions, and the simulation results demonstrate the feasibility and superior performance.
With the rapid development of wind power, the effects of doubly fed induction generators (DFIGs) on the transient stability of power system have attracted more attention. However, the effects are still not clear due to the lack of deep and theoretical analysis. A control method for enhancing system rotor angle stability enhancement is proposed with considering the power constraints of DFIG. The rotor angle oscillation of the synchronous generator (SG) can be reduced and overspeed and the overcurrent of DFIG can be avoided. In this paper, the effects of the DFIG on the rotor angle characteristics of SG are analyzed. The change law of system rotor angle varying with transient power of the DFIG is obtained. Then, the power equation in the emergency pitch control process is explored. The reactive power constraints of the stator and grid-side converter are deduced. Finally, the system rotor angle stability enhancement control method is proposed based on the power constraints of DFIG. The effectiveness of proposed method is proven by simulations.
With the increased use of high voltage direct current (HVDC) systems, line commutated converters (LCC-HVDC) and voltage source converters (VSC-HVDC) tend to feed into AC systems over short electrical distances. The flexible power control of VSC-HVDC systems provides an effective approach to suppress the commutation failure of LCC-HVDC systems. A suppression method, based on a controllable operation region, is proposed in this study to reduce the probability of commutation failure in a hybrid dual-infeed HVDC system. First, the quantitative transient reactive power control requirement of VSC-HVDC inverter that could fulfill the suppression control boundary condition of commutation failure was analyzed. Given the maximum current constraint of the VSC-HVDC inverter and the primary frequency modulation constraint of the sending-end grid, a controllable operation region of the hybrid dual-infeed HVDC system was proposed. Furthermore, a commutation failure suppression control method, based on the controllable operation region, was proposed to mitigate continuous commutation failure. Finally, the validity and accuracy of the proposed method was verified by the simulation of PSCAD/EMTDC. The proposed control method can realize reasonable use of the reactive power control capability of the VSC-HVDC system, which effectively improves immunity to commutation failure of the LCC-HVDC system under grid fault.
Continuous commutation failures (CFs) are serious malfunctions in line-commutated converter high-voltage direct current (HVDC) systems that cause the continuous and rapid sag of transmitted power and may threaten the stability of AC systems. The conventional emergency control strategies of AC systems exhibit difficulty in responding quickly and accurately. After suffering from continuous CFs, the forced blocking of direct current (DC) converter to prevent AC system instability might also cause other adverse effects. This study proposes a ride-through control method to improve the endurance capability of AC systems against continuous CFs. An active power output model of inverter station under continuous CFs is built, while considering the process and mechanism of CFs. The impact of continuous DC power sag on the stability of sending-end system is analyzed through a four-area AC/DC equivalent model. A rolling calculation model for the power angle and acceleration area variations of the sending-end system during continuous CFs is established on the basis of model predictive control theory. A calculation method for the emergency power control reference is obtained by using the aforementioned models. Lastly, a ride-through control method for continuous CFs is developed by utilizing the emergency control of adjacent HVDC link. Simulation results show that the proposed control method can improve the endurance capability of an AC system to continuous CFs and reduce blocking risk in an HVDC link.
This manuscript proposes a fast transient simulation method based on PEEC to model overvoltage caused by spark gap and disconnecting switch operations in UHV series compensation (FSC). It proposes a simulation method based on the Partial Element Equivalent Circuit (PEEC) for modeling the fast transient processes associated with the operation of primary equipment in UHV FSC. Initially, a multi-conductor system model for both primary and secondary equipment on the cascade platform is developed. Then, the lumped components′ modeling of primary equipment and secondary equipment is added on the basis of multi-conductor model. Through simulation, the rapid transient overvoltage of primary equipment and the electromagnetic disturbance of the secondary system are analyzed. The simulation results provide insights into the distribution of fast transient overvoltage and the transient electromagnetic disturbance along the bus, from the low-voltage bus to the high-potential platform, under various primary equipment operating conditions. These findings provide a basis for theoretical analysis of the layout of sensor devices on platform and the design of electromagnetic shielding for interference-prone systems on platform.