Andras Roosz

Prof. Dr. Andras Roosz

orcid

Research Focus & Metrics

Academic Career Length

40Years (1987-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 1990 in Acta Metallurgica et Materialia
Verified
Journal Article
Closed access
ARAndras Roosz
Andras Roosz
HEH.E. Exner
H.E. Exner

19 May 2022 in Crystals
Verified
Journal Article
Open access
PDF file
KAKassab Al-Omari
Kassab Al-Omari
ARAndras Roosz
Andras Roosz
ARArnold Rónaföldi
Arnold Rónaföldi
ZVZsolt Veres
Zsolt Veres
Al–Si eutectic alloys are industrially important; they play a significant role in the casting-manufacturing of most materials. The properties of the materials are governed by their microstructure, which can be tuned by adjusting the solidification process parameters. Herein, the effect of forced melt flow on the microstructure of an Al–Si eutectic alloy during unidirectional solidification was investigated experimentally. Al–12.6-wt%-Si alloy samples were solidified in a vertical Bridgman-type furnace equipped with a rotating magnetic inductor to induce flow in the melt. The samples were subjected to different magnetic induction conditions during the solidification experiments. The diameter of the samples was 8 mm, and their length was 120 mm. The eutectic alloy samples were solidified unidirectionally at a growth rate of v ≈ 0.1 mm/s and a temperature gradient of G ≈ 6 K/mm. The inter-lamellar distances (λ), lengths, and orientation angles of the Si lamellae were investigated using new measurement methods. The experimental results reveal that applying the rotating magnetic field (RMF) during the solidification has a distinct effect on the microstructure of Al–Si eutectic alloys. Indeed, the RMF refines the eutectic structure, reduces the interlamellar distances, and increases the diversity of the Si lamella angle’s orientations. However, the successive stirring process has a negligible effect on the lengths and angles of Si lamellae.

1 January 1987 in Materials Science Forum
Verified
Journal Article
Closed access
PDF file
EHE. Halder
E. Halder
ARAndras Roosz
Andras Roosz
HEHans Eckart Exner
Hans Eckart Exner
HFH.F. Fischmeister
H.F. Fischmeister

10 December 2024 in Materials
Verified
Journal Article
Open access
PDF file
DZDIMAH ZAKARAIA
DIMAH ZAKARAIA
ARAndras Roosz
Andras Roosz
ARArnold Rónaföldi
Arnold Rónaföldi
ZVZsolt Veres
Zsolt Veres
The microstructure of hypereutectic Al-Si alloys is crucial in determining their mechanical properties and overall performance in engineering applications. This paper investigates the effect of a rotating magnetic field (RMF) and eutectic front velocity on the microstructure of hypereutectic Al-18 wt.% Si alloy. The hypereutectic samples were solidified using five different front velocities (0.02, 0.05, 0.09, 0.2, and 0.4 mm/s) with an average temperature gradient (G) of 8 K/mm in a crystallizer equipped with an RMF inductor. The samples were solidified into two sections. The first section solidified without stirring, while the second section solidified with stirring using RMF at an induction (B) of 7.2 mT. The length, angular orientation of eutectic Si lamellas, and interlamellar distances were measured in both the non-stirred and the stirred sections to evaluate the impact of RMF and front velocity on the eutectic structure. The results revealed that the application of RMF and the increase in front velocity during solidification led to the significant refinement of the eutectic structure. These findings highlight the potential of RMF and front velocity manipulation to enhance the microstructure of hypereutectic Al-Si alloys, with practical implications for the development of high-performance materials.

26 March 2013 in Materials Science Forum
Verified
Journal Article
Closed access
PDF file
ARAndras Roosz
Andras Roosz
JKJenő Kovács
Jenő Kovács
ARArnold Rónaföldi
Arnold Rónaföldi
ÁKÁrpád Kovács
Árpád Kovács
Al–7wt.-% Si–1wt.-% Fe alloy was solidified unidirectionally in the Crystallizer with High Rotating Magnetic Field (CHRMF). The diameter of sample was 8 mm and its length was 120 mm. The parameters of solidification were as follows: solid/liquid interface velocity ~0.082 mm/s, temperature gradient 7+/-1 K/mm, magnetic induction 0 and 150 mT, frequency of magnetic field 0 and 50 Hz. The structure solidified without rotating magnetic field (RMF) showed a homogeneous, columnar dendritic one. The structure solidified by using magnetic stirring showed a dual periodicity. On the one hand, the branches of the “Christmas tree”-like structure known from the earlier experiments contained Al+Si binary eutectic. On the other hand, bands with higher Fe- and Si-content formed in the sample, which were at a larger distance from each other than the branches of the “Christmas tree” structure. The developed microstructure was analyzed by SEM with EDS. The average Si- and Fe-concentrations were measured on the longitudinal section at given places along the length of sample. Furthermore the Si- and the Fe-concentrations close to the bands and among the bands as well as the composition of the compound phases were determined.

1 May 2014 in Materials Science Forum
Verified
Journal Article
Open access
PDF file
MSMaria Sveda
Maria Sveda
ASAnna Sycheva
Anna Sycheva
JKJenő Kovács
Jenő Kovács
ARArnold Rónaföldi
Arnold Rónaföldi
ARAndras Roosz
Andras Roosz
The peritectic alloys, such as some types of steel, Ni-Al, Fe-Ni, Ti-Al, Cu-Sn, are commercially important. In contrast to other types of alloys, many unique structures (e.g. banded or island ones) can form when peritectic alloys are directionally solidified under various solidification conditions. It can be observed in the course of the directional solidification experiments performed in a rotating magnetic field (RMF) that the melt flow has a significant effect on the solidified structure of Sn-Cd alloys. This effect was investigated experimentally for the case of Sn1.6 wt% Cd peritectic alloy. For this purpose, a Bridgman-type gradient furnace was equipped with an inductor, which generates a rotating magnetic field in order to induce a flow in the melt. As a result, the forced melt flow substantially changes the solidified cellular microstructure. The cell size and the volume fraction of the primary tin phase were measured by an image analyzer on the longitudinal polished sections along the entire length of the samples. The microstructure was investigated by scanning electron microscope (SEM) equipped with an energy dispersive spectrometer (EDS).