The 3D surface measurement plays a significant role in the industrial area. With the advantages of high resolution and acquisition rate, dual line-scan cameras system have been gradually studied for dynamic 3D measurement. However, the partial overexposure and the limited measurement depth range of dual line-scan cameras are the two main elements affecting the quality of the point cloud. Both of these problems are caused by incorrect pixel matching. Therefore, this paper present a matching strategy for dual line-scan cameras based on the one-dimensional background-normalized Fourier transform (1DBNFT) to expands the depth range of measurement and deal with the partial overexposure. The wrapped phases extracted by 1DBNFT, the unwrapped phase extracted by projection distance minimization (PDM), and the matching principle are described in detail. We also analyze the possible errors in the system from three aspects, that are noncoplanar error, installation error, and motion error. Finally, the comparative experiments and accuracy verification experiments demonstrate the effectiveness of our algorithm.
9 March 2023 in IEEE Transactions on Instrumentation and Measurement
Generating a large-scale high-density point cloud is crucial for 3-D shape measurements. Both area-scan and line-scan camera systems have advantages and limitations for large-scale structured light measurement. Consequently, we propose a method that achieves complementary advantages of both the camera systems through flexible continuous scanning with high resolution and frequency. For point cloud generation, efficient scanning in continuous motion with high resolution, large field of view, and high frequency is realized using line-scan cameras. A flexible registration strategy without mechanical positioning is proposed for point cloud registration after referring to the registration methods in area-scan camera systems. To realize the above functions, system structure and calibration are designed. Techniques for point cloud generation with high dynamic performance and interference resistance are introduced. The point cloud registration strategy includes methods for high-frequency pose acquisition and processing. Moreover, an optimization method is designed for the point cloud after registration, and the texture is attached. The proposed system has excellent prospects for large-scale industrial component measurements.
With outstanding features of high resolution and high acquisition rate, line-scan imaging holds great potentials for high-speed applications. This paper presents a stereo line-scan system for 3D shape measurement of fast moving objects. The principle and key technologies are addressed. The system setup and 3D imaging model are introduced first and the stereo matching scheme and calibration approach are described subsequently. The system is verified by experiments. The results demonstrate the validity and accuracy of the proposed system.
A metrology method dedicated to position monitoring and correction for the ptychography setup at the High Energy Photon Source (HEPS, Beijing, China) beamline ID09 is proposed. The sophisticated design of the Invar interferometer metrology frame ensures optimal performance within the compact environment between the focal spot and the sample setup. The measurement method and error analysis are described in detail. The sample setup achieves a positional stability of less than 2 nm RMS from 1 Hz to 500 Hz. The 12.3 nm reconstruction resolution of 2D ptychography at 12.4 keV demonstrates that the interferometer metrology strategy is available.
The first water-cooling nano multilayer Kirkpatrick–Baez mirror system in the Structural Dynamics beamline (ID23) at High Energy Photon Source (HEPS) has been implemented. An Invar gantry is engineered to achieve a balance between light weight and stability. The cooling system, including eutectic gallium–indium (eGaIn), copper braids and a cooling water circuit with a multi-bend copper pipe in a compact space, decouples movement and mitigates vibration. The mirror cooling holders introduce less than 0.5 nm RMS height error and 0.1 µrad RMS slope error in the mirror surface shapes. A series of stability tests is applied to verify the mechanism structure. In a 1 h test assessment using a water-cooling flow of 4.5 L min −1 , the system demonstrated a positional stability of 5.96 nm and an angular stability of 86.76 nrad from 1 Hz to 500 Hz. The focal spot size of 13.39 nm × 15.15 nm (H × V) at a photon energy of 21.8 keV demonstrates the system's performance.