Tomas Suchacek

Mr. Tomas Suchacek


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2018 in Water
Verified
Journal Article
Open access
PDF file
JRJan Ručka
Jan Ručka
JHJan Holešovský
Jan Holešovský
TSTomas Suchacek
Tomas Suchacek
LTLadislav Tuhovcak
Ladislav Tuhovcak
Pressure management is the basic step of reducing water losses from water supply systems (WSSs). The reduction of direct water losses is reliably achieved by reducing pressure in the WSSs. There is also a slight decrease in water consumption in connected properties. Nevertheless, consumption is also affected by other factors, the quantification of which is not trivial. However, there is still a lack of much relevant information to enter into this analysis and subsequent decision making. This article focuses on water consumption and its prediction, using regression models designed for an experiment regarding an administrative building in the Czech Republic (CZ). The variables considered are pressure and climatological factors (temperature and humidity). The effects of these variables on the consumption are separately evaluated, subsequently multidimensional models are discussed with the common inclusion of selected combinations of predictors. Separate evaluation results in a value of the N3 coefficient, according to the FAVAD concept used for prediction of changes in water consumption related to pressure. The statistical inference is based on the maximum likelihood method. The proposed regression models are tested to evaluate their suitability, particularly, the models are compared using a cross-validation procedure. The significance tests for parameters and model reduction are based on asymptotic properties of the likelihood ratio statistics. Pressure is confirmed in each regression model as a significant variable.

2 August 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
TSTomas Suchacek
Tomas Suchacek
AAAlexandru Aldea
Alexandru Aldea
Jedrzej BylkaJedrzej Bylka
Jedrzej Bylka
IMIvana Marko
Ivana Marko
LTLadislav Tuhovcak
Ladislav Tuhovcak
This paper deals with a comparative analysis and benchmarking of drinking water supply systems and water supply sector in the selected countries of Central and Eastern Europe. These include the Czech Republic, Poland, Romania, and Slovakia. The article provides an analysis of existing benchmarking systems in each country. Methods of supervision and control over the assessment and the functioning of the organizations responsible for the assessment and benchmarking of water utilities are also described. Comparative analysis for the selected performance indicators is carried out. The units, methods of data collection and processing were described.

6 February 2018 in E3S Web of Conferences
Verified
Conference Paper
Open access
TSTomas Suchacek
Tomas Suchacek
LTLadislav Tuhovcak
Ladislav Tuhovcak
JRJan Rucka
Jan Rucka
This article deals with sensitivity analysis of real water consumption in an office building. During a long-term real study, reducing of pressure in its water connection was simulated. A sensitivity analysis of uneven water demand was conducted during working time at various provided pressures and at various time step duration. Correlations between maximal coefficients of water demand variation during working time and provided pressure were suggested. The influence of provided pressure in the water connection on mean coefficients of water demand variation was pointed out, altogether for working hours of all days and separately for days with identical working hours.

2 August 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
LTLadislav Tuhovcak
Ladislav Tuhovcak
TSTomas Suchacek
Tomas Suchacek
JRJan Ručka
Jan Ručka
The paper presents results and sensitivity analysis of the results of a real detailed study focused on changes in water consumption and its unevenness with changing pressure conditions in a particular observed office building. The dependence of water consumption on pressure is expressed using the FAVAD equation using the N3 coefficient. Parameters for sensitivity analysis are number of workers in the building, pulse value from water meter and length of time step for expressing unevenness of water consumption during the day.