When working in radiology and patient assistance in medical facilities, radiation workers need to understand how to properly protect themselves and others from scattered radiation. In this study, a visualisation method is examined to facilitate the understanding of the spread of scattered radiation in radiography, computerised tomography (CT), and angiography rooms, and the application of this system for radiation protection education is proposed. X-ray radiography, x-ray CT, and angiography rooms were constructed using the particle and heavy ion transport code system, and the scattered radiation distributions that occurred when a patient was irradiated with x-rays were simulated. The three-dimensional (3D) distribution of each moment was continuously displayed to create a four-dimensional (4D) distribution. Using the obtained data, a radiation protection education seminar was conducted that included exercises to allow the students to confirm the presence of scattered radiation from any direction. The effectiveness of the scattered radiation visualisation data was evaluated using an interview. The position of the assistant for conducting standing chest radiographs that experienced the least scattered radiation was determined to be at the side and foot side of the patient. As a result of an interview that was provided to the participants following the seminar, the effectiveness of this system for providing education about radiation protection was confirmed. The visualisation method allowed the students to better understand the behaviour of radiation and the sources of scattered radiation. The visualisation of 3D and 4D scattered radiation distributions in radiological examination rooms can intuitively enhance the understanding of the spread of invisible radiation and the appropriate methods of mitigating radiation exposure.
17 January 2022 in Journal of Radiological Protection
Understanding the behaviour of scattered radiation is important for learning appropriate radiation protection methods, but many existing visualisation systems for radiation require special devices, making it difficult to use them in education. The purpose of this study was to develop teaching material for radiation protection that can help visualise the scattered radiation with augmented reality (AR) and virtual reality (VR) on a web browser, develop a method for using it in education and examine its effectiveness. The distribution of radiation during radiography was calculated using Monte Carlo simulation, and teaching material was created. The material was used in a class for department of radiological technology students and its influence on motivation was evaluated using a questionnaire based on the evaluation model for teaching materials. In addition, text mining was used to evaluate impressions objectively. Educational material was developed that can be used in AR and VR for studying the behaviour of scattered radiation. The results of the questionnaire showed that the average value of each item was more than four on a five-point scale, indicating that the teaching material attracted the interest of users. Through text mining, it could be concluded that there was improved understanding of, and confidence in, radiation protection.
15 October 2019 in Radiological Physics and Technology
To decrease radiation exposure to medical staff performing angiography, the dose distribution in the angiography was calculated in room using the particle and heavy ion transport code system (PHITS), which is based on Monte Carlo code, and the source of scattered radiation was confirmed using a tungsten sheet by considering the difference shielding performance among different sheet placements. Scattered radiation generated from a flat panel detector, X-ray tube and bed was calculated using the PHITS. In this experiment, the source of scattered radiation was identified as the phantom or acrylic window attached to the X-ray tube thus, a protection curtain was placed on the bed to shield against scattered radiation at low positions. There was an average difference of 20% between the measured and calculated values. The H*(10) value decreased after placing the sheet on the right side of the phantom. Thus, the curtain could decrease scattered radiation.
10 February 2011 in Radiation Protection Dosimetry
The radioactivation of linear accelerator components for radiation therapy is interest for radiation protection in general, and particularly, when decommissioning these structures. The energy spectra of gamma rays emitted from the heads of two accelerator models, EXL-15SP and Clinac iX, after 10-MeV X-ray irradiation, were measured using a high-purity germanium semiconductor survey meter. After spectrum analyses, activities of 24Na, 28Al, 54Mn, 56Mn, 57Ni, 58Co, 60Co, 64Cu, 65Zn, 122Sb, 124Sb, 181W, 187W, 196Au, and 198Au were detected. One centimetre deep dose-equivalent rate of the heads of the linear accelerator was measured using the survey meter. The dose rate decreased to ∼10 % of its initial rate after 1 week. Long-term activations were few, the radioactivity level was low, and a cooling time of several days was effective for reducing dose rate to an acceptable level for decommissioning.