A practical approach for improving tracking performance of the predictive functional control (PFC) is proposed. The disturbance observer is utilized to nominalize the actual plant and to reduce the predicted output error in the PFC algorithm by canceling not only constant but also high-order disturbances. The proposed control scheme is experimentally validated on a single axis table drive system and is compared with the standard PFC and the industrial cascade control. The experimental results prove the effectiveness of the proposed disturbance observer-based PFC scheme.
In this paper, we propose a double air chambers artificial muscle to eliminate the hysteresis in the extension and contraction movement of pneumatic artificial muscles. In this paper, the basic structure of the double air chambers artificial muscle is a rubberless artificial muscle with a particularly large hysteresis loop. The double air chambers artificial muscle aims to eliminate hysteresis by directly pressurizing the inside and outside of the air chamber and actively deforming the air chamber. The hysteresis is reduced by the pressure outside of the air chamber (external pressure). Since the appropriate external pressure varies depending on the contraction force and amount of contraction, we proposed a method to regulate the appropriate external pressure by feedback control. The experimental results show that hysteresis was eliminated in the static characteristics. It was also found that the output gain decreased, and the phase lag increased as the target frequency increased. The output gain did not change with increasing load. The phase lag tended to improve with the PID controller compared to the PI controller. These results suggest that the combination of double air chambers artificial muscle and external pressure-regulated feedback control can achieve non-hysteresis position control, and it is useful as an actuator in mechatronic systems.
Shortage of labor and increased work of young people are causing problems in terms of care and welfare of a growing proportion of elderly people. This is a looming social problem because people of advanced ages are increasing. Necessary in the fields of care and welfare, pneumatic artificial muscles in actuators of robots are being examined. Pneumatic artificial muscles have a high output per unit of weight, and they are soft, similarly to human muscles. However, in previous research of robots using pneumatic artificial muscles, rigid sensors were often installed at joints and other locations due to the robots’ structures. Therefore, we developed a smart actuator that integrates a bending sensor that functions as a human muscle spindle; it can be externally attached to the pneumatic artificial muscle. This paper reports a smart artificial muscle actuator that can sense contraction, which can be applied to developed self-monitoring and robot posture control.
20 October 2020 in Journal of Robotics and Mechatronics
This paper describes a semi-crouching assistive device using pneumatic artificial muscles. The goal of this device is to reduce the load on the lower back when performing work in the semi-crouching position. The load on the lower back is reduced by decreasing the compressive pressure on the lumbar disk of the lower back. This compressive pressure increases as the contraction force of the erector spine increases. Therefore, it is important to reduce the muscle activity of the erector spine. Based on the analytical result of a worker’s position model, the proposed device adopts a scheme to push the chest of the user as an appropriate assistive method. Additionally, the analytical result shows that a reduction in weight of the device is also important for decreasing the load on the lower back. Based on these results, we prototyped a lightweight semi-crouching assistive device that can generate sufficient assistive force via a pneumatic artificial muscle, which has high power to weight ratio. This device was experimentally evaluated via electromyogram of the erector spine when the user maintains a semi-crouching position. The experimental results confirmed the usefulness of this device.
26 June 2019 in Industrial Robot: the international journal of robotics research and application
Purpose: The purpose of this study is to confirm that the body weight load reduction system which is developed by us is effective to reduce the knee joint force of the walking user. This system is driven by pneumatic artificial muscle, functions as a mobile walking assist system. Design/methodology/approach: The developed body weight load reduction system driven by rubber-less artificial muscle (RLAM) was tested experimentally. Simple force feedback control is applied to the RLAM. The system moves as synchronized with vertical movement of the walking user. The knee joint force during walking experiments conducted using this system is estimated by measurement of floor reaction force and position data of lower limb joints. Findings: The knee joint force during walking is reduced when using this system. This system contributes to smooth change of knee joint force when the lower limb contacts the floor. Practical implications: This lightweight body weight load reduction system is particularly effective for realizing easy-to-use mobile walking assist system. Originality/value: A lightweight body weight load reduction system using pneumatic artificial muscle is a novel proposal. Additionally, these new evaluation results demonstrate its effectiveness for reducing knee joint force during walking.
Most BCI systems used in neurorehabilitation detect EEG features indicating motor intent based on machine learning, focusing on repetitive movements, such as limb flexion and extension. These machine learning methods require large datasets and are time consuming, making them unsuitable for same-day rehabilitation training following EEG measurements. Therefore, we propose a BMI system based on fuzzy inference that bypasses the need for specific EEG features, introducing an algorithm that allows patients to progress from measurement to training within a few hours. Additionally, we explored the integration of electromyography (EMG) with conventional EEG-based motor intention estimation to capture continuous movements, which is essential for advanced motor function training, such as skill improvement. In this study, we developed an algorithm that detects the initial movement via EEG and switches to EMG for subsequent movements. This approach ensures real-time responsiveness and effective handling of continuous movements. Herein, we report the results of this study.