David McKeown

Dr. David McKeown

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2012
Verified
Conference Paper
Closed access
EDEmer P. Doheny
Emer P. Doheny
DMDenise McGrath
Denise McGrath
BGBarry R. Greene
Barry R. Greene
LWLorcan Walsh
Lorcan Walsh
DMDavid McKeown
David McKeown
Brian CaulfieldBrian Caulfield
Brian Caulfield
Postural sway during quiet standing is associated with falls risk in older adults. The aim of this study was to investigate the utility of a range of accelerometer-derived parameters of centre of mass (COM) displacement in identifying older adults at risk of falling. A series of instrumented standing balance trials were performed to investigate postural control in a group of older adults, categorised as fallers or non-fallers. During each trial, participants were asked to stand as still as possible under two conditions: comfortable stance (six repetitions) and semi-tandem stance (three repetitions). A tri-axial accelerometer was secured to the lower back during the trials. Accelerometer data were twice integrated to estimate COM displacement during the trials, with numerical techniques used to reduce integration error. Anterior-posterior (AP) and medial-lateral (ML) sway range, sway length and sway velocity were examined, along with root mean squared (RMS) acceleration. All derived parameters significantly discriminated fallers from non-fallers during both comfortable and semi-tandem stance. Results indicate that these accelerometer-based estimates of COM displacement may improve the discriminative power of quiet standing falls risk assessments, with potential for use in unsupervised balance assessment.

8 September 2021 in Aerospace
Verified
Journal Article
Open access
PDF file
SWSarah Walsh
Sarah Walsh
DMDavid Murphy
David Murphy
MDMaeve Doyle
Maeve Doyle
JRJack Reilly
Jack Reilly
JTJoseph Thompson
Joseph Thompson
SMSheila McBreen
Sheila McBreen
The Educational Irish Research Satellite (EIRSAT-1) is a 2U CubeSat developed at University College Dublin. The project aims to build, test, launch, and operate Ireland’s first satellite and to perform in-orbit demonstrations of three novel payloads developed in-house. To reduce risk within the mission, the project employs a prototype model philosophy in which two models of the spacecraft exist: an engineering qualification model (EQM) and a flight model (FM). This paper presents the verification approach of the functional tests implemented for the EIRSAT-1 project. The activities of the FlatSat and system level full functional tests of the EQM are presented and the results obtained during the test campaigns are discussed. Four test anomalies were encountered during the full functional test campaign resulting in two minor redesigns, and subsequent reassembly, of the CubeSat. The functional test campaigns highlighted the importance of FlatSat level testing of CubeSats to ensure compatibility of all subsystems prior to assembly and of thorough documentation to diagnose any unexpected behaviour of the hardware efficiently. The functional verification of the EQM proved that the system conformed to its design, verifying 57 mission requirements, and is a crucial step towards the development of the EIRSAT-1 FM.

12 February 2022 in Aerospace
Verified
Journal Article
Open access
PDF file
RDRachel Dunwoody
Rachel Dunwoody
JRJack Reilly
Jack Reilly
DMDavid Murphy
David Murphy
MDMaeve Doyle
Maeve Doyle
JTJoseph Thompson
Joseph Thompson
SMSheila McBreen
Sheila McBreen
CubeSats facilitate rapid development and deployment of missions for educational, technology demonstration, and scientific purposes. However, they are subject to a high failure rate, with a leading cause being the lack of system-level verification. The Educational Irish Research Satellite (EIRSAT-1) is a CubeSat mission under development in the European Space Agency’s (ESA) Fly Your Satellite! Programme. EIRSAT-1 is a 2U CubeSat with three novel payloads and a bespoke antenna deployment module, which all contribute to the complexity of the project. To increase the likelihood of mission success, a prototype model philosophy is being employed, where both an engineering qualification model (EQM) and a flight model of EIRSAT-1 are being built. Following the assembly of the EQM, the spacecraft underwent a successful full functional test and month-long mission test. An environmental test campaign in ESA Education Office’s CubeSat Support Facility was then conducted with the EQM where both vibration and thermal verification test campaigns were performed. The focus of this paper is the thermal testing and verification of the EIRSAT-1 EQM. Over three weeks, the EQM was subjected to one non-operational cycle, three and a half operational cycles, and a thermal balance test in a thermal vacuum chamber. After dwelling at each temperature extreme, functional tests were performed to investigate the performance of the spacecraft in this space representative environment. The approach to planning and executing the thermal testing is described in detail including the documentation required, set up of the test equipment, and determination of the test levels. Overall, the campaign demonstrated that the mission can successfully operate in a space environment similar to that expected in orbit, despite encountering a number of issues. These issues included a payload displaying anomalous behaviour at cold temperatures and needing to redefine test levels due to an insufficient understanding of the internal dissipation in the spacecraft. A total of two major and three minor non-conformances were raised. Crucially, these issues could not have been found without thermal testing, despite the comprehensive ambient tests performed. The main results and lessons learned during this thermal test campaign are presented with the aim of guiding future missions on optimal approaches in organising and executing the thermal testing of their CubeSats.

1 August 2012
Verified
Conference Paper
Closed access
DMDenise McGrath
Denise McGrath
EDEmer P. Doheny
Emer P. Doheny
LWLorcan Walsh
Lorcan Walsh
DMDavid McKeown
David McKeown
CCClodagh Cunningham
Clodagh Cunningham
BGBarry R. Greene
Barry R. Greene
We investigated three methods for estimating centre of pressure excursions, as measured using a portable pressure sensor matrix, in order to deploy similar technology into the homes of older adults for longitudinal monitoring of postural control and falls risk. We explored the utility of these three methods as markers of falls risk in a cohort of 120 community dwelling older adults with and without a history of falls (65 fallers, 55 non-fallers). A number of standard quantitative balance parameters were derived using each centre of pressure estimation method. Rank sum tests were used to test for significant differences between fallers and non-fallers while intra-class correlation coefficients were also calculated to determine the reliability of each method. A method based on estimating the changes in the magnitude of pressure exerted on the pressure sensor matrix was found to be the most reliable and discriminative. Our future work will implement this method for home-based balance measurement.

29 November 2010 in Journal of Dynamic Systems, Measurement, and Control
Verified
Journal Article
Closed access
PDF file
WOWilliam J. O’cOnnor
William J. O’cOnnor
DMDavid McKeown
David McKeown
This paper presents a new, robust, time-optimal control strategy for flexible manipulators controlled by acceleration-limited actuators. The strategy is designed by combining the well-known, open-loop, time-optimal solution with wave-based feedback control. The time-optimal solution is used to design a new launch wave input to the wave-based controller, allowing it to recreate the time-optimal solution when the system model is exactly known. If modeling errors are present or a real actuator is used, the residual vibrations, which would otherwise arise when using the time-optimal solution alone, are quickly suppressed due to the additional robustness provided by the wave-based controller. A proximal time-optimal response is still achieved. A robustness analysis shows that significant improvements can be achieved using wave-based control in conjunction with the time-optimal solution. The implications and limits are also discussed.

11 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
SESonja Egan
Sonja Egan
PBPieter A.J. Brama
Pieter A.J. Brama
CGCathy Goulding
Cathy Goulding
DMDavid McKeown
David McKeown
CKClodagh Kearney
Clodagh Kearney
DMDenise McGrath
Denise McGrath
(1) Background: Postural sway is frequently used to quantify human postural control, balance, injury, and neurological deficits. However, there is considerably less research investigating the value of the metric in horses. Much of the existing equine postural sway research uses force or pressure plates to examine the centre of pressure, inferring change at the centre of mass (COM). This study looks at the inverse, using an inertial measurement unit (IMU) on the withers to investigate change at the COM, exploring the potential of postural sway evaluation in the applied domain. (2) Methods: The lipopolysaccharide model was used to induce transient bilateral lameness in seven equines. Horses were monitored intermittently by a withers fixed IMU over seven days. (3) Results: There was a significant effect of time on total protein, carpal circumference, and white blood cell count in the horses, indicating the presence of, and recovery from, inflammation. There was a greater amplitude of displacement in the craniocaudal (CC) versus the mediolateral (ML) direction. A significant difference was observed in the amplitude of displacement in the ML direction between 4–12 h and 168 h. (4) Conclusions: The significant reduction in ML displacement during the acute inflammation period alongside greater overall CC displacement may be a compensatory behaviour for bilateral lameness.