Lorcan Walsh

Lorcan Walsh

Auto-generated profile, based on publicly available information

Lorcan Walsh

Data Sciences Novartis Business Services Dublin Ireland

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2014 in The Lancet Neurology
Verified
Journal Article
Closed access
LBLaura K Barger
Laura K Barger
EFErin E Flynn-Evans
Erin E Flynn-Evans
AKAlan Kubey
Alan Kubey
LWLorcan Walsh
Lorcan Walsh
JRJoseph M Ronda
Joseph M Ronda
CCCharles A Czeisler
Charles A Czeisler

20 April 2020 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
AKAlison Keogh
Alison Keogh
JDJonas F Dorn
Jonas F Dorn
LWLorcan Walsh
Lorcan Walsh
FCFrancesc Calvo
Francesc Calvo
Brian CaulfieldBrian Caulfield
Brian Caulfield
Background: Wearable devices are valuable assessment tools for patient outcomes in contexts such as clinical trials. To be successfully deployed, however, participants must be willing to wear them. Another concern is that usability studies are rarely published, often fail to test devices beyond 24 hours, and need to be repeated frequently to ensure that contemporary devices are assessed. Objective: This study aimed to compare multiple wearable sensors in a real-world context to establish their usability within an older adult (>50 years) population. Methods: Eight older adults wore seven devices for a minimum of 1 week each: Actigraph GT9x, Actibelt, Actiwatch, Biovotion, Hexoskin, Mc10 Biostamp_RC, and Wavelet. Usability was established through mixed methods using semistructured interviews and three questionnaires, namely, the Intrinsic Motivation Inventory (IMI), the System Usability Scale (SUS), and an acceptability questionnaire. Quantitative data were reported descriptively and qualitative data were analyzed using deductive content analysis. Data were then integrated using triangulation. Results: Results demonstrated that no device was considered optimal as all scored below average in the SUS (median, IQR; min-max=57.5, 12.5; 47.5-63.8). Hexoskin was the lowest scored device based on the IMI (3.6; 3.4-4.5), while Biovotion, Actibelt, and Mc10 Biostamp_RC achieved the highest median results on the acceptability questionnaire (3.6 on a 6-point Likert scale). Qualitatively, participants were willing to accept less comfort, less device discretion, and high charging burdens if the devices were perceived as useful, namely through the provision of feedback for the user. Participants agreed that the purpose of use is a key enabler for long-term compliance. These views were particularly noted by those not currently wearing an activity-tracking device. Participants believed that wrist-worn sensors were the most versatile and easy to use, and therefore, the most suitable for long-term use. In particular, Actiwatch and Wavelet stood out for their comfort. The convergence of quantitative and qualitative data was demonstrated in the study. Conclusions: Based on the results, the following context-specific recommendations can be made: (1) researchers should consider their device selection in relation to both individual and environmental factors, and not simply the primary outcome of the research study; (2) if researchers do not wish their participants to have access to feedback from the devices, then a simple, wrist-worn device that acts as a watch is preferable; (3) if feedback is allowed, then it should be made available to help participants remain engaged; this is likely to apply only to people without cognitive impairments; (4) battery life of 1 week should be considered as a necessary feature to enhance data capture; (5) researchers should consider providing additional information about the purpose of devices to participants to support their continued use.

27 November 2019 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
AMArne Mueller
Arne Mueller
HHHolger Alfons Hoefling
Holger Alfons Hoefling
AMAmir Muaremi
Amir Muaremi
JPJens Praestgaard
Jens Praestgaard
LWLorcan C Walsh
Lorcan C Walsh
ICIeuan Clay
Ieuan Clay
Background: Digital technologies and advanced analytics have drastically improved our ability to capture and interpret health-relevant data from patients. However, only limited data and results have been published that demonstrate accuracy in target indications, real-world feasibility, or the validity and value of these novel approaches. Objective: This study aimed to establish accuracy, feasibility, and validity of continuous digital monitoring of walking speed in frail, elderly patients with sarcopenia and to create an open source repository of raw, derived, and reference data as a resource for the community. Methods: Data described here were collected as a part of 2 clinical studies: an independent, noninterventional validation study and a phase 2b interventional clinical trial in older adults with sarcopenia. In both studies, participants were monitored by using a waist-worn inertial sensor. The cross-sectional, independent validation study collected data at a single site from 26 naturally slow-walking elderly subjects during a parcours course through the clinic, designed to simulate a real-world environment. In the phase 2b interventional clinical trial, 217 patients with sarcopenia were recruited across 32 sites globally, where patients were monitored over 25 weeks, both during and between visits. Results: We have demonstrated that our approach can capture in-clinic gait speed in frail slow-walking adults with a residual standard error of 0.08 m per second in the independent validation study and 0.08, 0.09, and 0.07 m per second for the 4 m walk test (4mWT), 6-min walk test (6MWT), and 400 m walk test (400mWT) standard gait speed assessments, respectively, in the interventional clinical trial. We demonstrated the feasibility of our approach by capturing 9668 patient-days of real-world data from 192 patients and 32 sites, as part of the interventional clinical trial. We derived inferred contextual information describing the length of a given walking bout and uncovered positive associations between the short 4mWT gait speed assessment and gait speed in bouts between 5 and 20 steps (correlation of 0.23) and longer 6MWT and 400mWT assessments with bouts of 80 to 640 steps (correlations of 0.48 and 0.59, respectively). Conclusions: This study showed, for the first time, accurate capture of real-world gait speed in slow-walking older adults with sarcopenia. We demonstrated the feasibility of long-term digital monitoring of mobility in geriatric populations, establishing that sufficient data can be collected to allow robust monitoring of gait behaviors outside the clinic, even in the absence of feedback or incentives. Using inferred context, we demonstrated the ecological validity of in-clinic gait assessments, describing positive associations between in-clinic performance and real-world walking behavior. We make all data available as an open source resource for the community, providing a basis for further study of the relationship between standardized physical performance assessment and real-world behavior and independence.


15 November 2012 in Physiological Measurement
Verified
Journal Article
Closed access
BGBarry R. Greene
Barry R. Greene
DMDenise McGrath
Denise McGrath
LWLorcan Walsh
Lorcan Walsh
EDEmer P Doheny
Emer P Doheny
DMDavid McKeown
David McKeown
RKRose A Kenny
Rose A Kenny
Falls are the most common cause of injury and hospitalization and one of the principal causes of death and disability in older adults worldwide. Measures of postural stability have been associated with the incidence of falls in older adults. The aim of this study was to develop a model that accurately classifies fallers and non-fallers using novel multi-sensor quantitative balance metrics that can be easily deployed into a home or clinic setting. We compared the classification accuracy of our model with an established method for falls risk assessment, the Berg balance scale. Data were acquired using two sensor modalities--a pressure sensitive platform sensor and a body-worn inertial sensor, mounted on the lower back--from 120 community dwelling older adults (65 with a history of falls, 55 without, mean age 73.7 ± 5.8 years, 63 female) while performing a number of standing balance tasks in a geriatric research clinic. Results obtained using a support vector machine yielded a mean classification accuracy of 71.52% (95% CI: 68.82-74.28) in classifying falls history, obtained using one model classifying all data points. Considering male and female participant data separately yielded classification accuracies of 72.80% (95% CI: 68.85-77.17) and 73.33% (95% CI: 69.88-76.81) respectively, leading to a mean classification accuracy of 73.07% in identifying participants with a history of falls. Results compare favourably to those obtained using the Berg balance scale (mean classification accuracy: 59.42% (95% CI: 56.96-61.88)). Results from the present study could lead to a robust method for assessing falls risk in both supervised and unsupervised environments.

1 August 2012
Verified
Conference Paper
Closed access
EDEmer P. Doheny
Emer P. Doheny
DMDenise McGrath
Denise McGrath
BGBarry R. Greene
Barry R. Greene
LWLorcan Walsh
Lorcan Walsh
DMDavid McKeown
David McKeown
Brian CaulfieldBrian Caulfield
Brian Caulfield
Postural sway during quiet standing is associated with falls risk in older adults. The aim of this study was to investigate the utility of a range of accelerometer-derived parameters of centre of mass (COM) displacement in identifying older adults at risk of falling. A series of instrumented standing balance trials were performed to investigate postural control in a group of older adults, categorised as fallers or non-fallers. During each trial, participants were asked to stand as still as possible under two conditions: comfortable stance (six repetitions) and semi-tandem stance (three repetitions). A tri-axial accelerometer was secured to the lower back during the trials. Accelerometer data were twice integrated to estimate COM displacement during the trials, with numerical techniques used to reduce integration error. Anterior-posterior (AP) and medial-lateral (ML) sway range, sway length and sway velocity were examined, along with root mean squared (RMS) acceleration. All derived parameters significantly discriminated fallers from non-fallers during both comfortable and semi-tandem stance. Results indicate that these accelerometer-based estimates of COM displacement may improve the discriminative power of quiet standing falls risk assessments, with potential for use in unsupervised balance assessment.