Norma Del Risco

Ms. Norma Del Risco

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
YLYanliang Li
Yanliang Li
BBBasma Baccouche
Basma Baccouche
NRNorma Del Risco
Norma Del Risco
JPJason Park
Jason Park
ASAmy Song
Amy Song
ANDRIUS KAZLAUSKASANDRIUS KAZLAUSKAS
ANDRIUS KAZLAUSKAS
The purpose of this study was to investigate the reason that diabetic retinopathy (DR) is delayed from the onset of diabetes (DM) in diabetic mice. To this end, we tested the hypothesis that the deleterious effects of DM are initially tolerated because endogenous antioxidative defense is elevated and thereby confers resistance to oxidative stress-induced death. We found that this was indeed the case in both type 1 DM (T1D) and type 2 DM (T2D) mouse models. The retinal expression of antioxidant defense genes was increased soon after the onset of DM. In addition, ischemia/oxidative stress caused less death in the retinal vasculature of DM versus non-DM mice. Further investigation with T1D mice revealed that protection was transient; it waned as the duration of DM was prolonged. Finally, a loss of protection was associated with the manifestation of both neural and vascular abnormalities that are diagnostic of DR in mice. These observations demonstrate that DM can transiently activate protection from oxidative stress, which is a plausible explanation for the delay in the development of DR from the onset of DM.

Verified
Journal Article
Open access
PDF file
NRNorma Del Risco
Norma Del Risco
CTChad L. Talbot
Chad L. Talbot
KMKayvon A. Moin
Kayvon A. Moin
GMGarrett N Manion
Garrett N Manion
ABAlex H Brown
Alex H Brown
Majid MoshirfarMajid Moshirfar
Majid Moshirfar
Background/Objectives: This retrospective case series analyzed visual outcomes in patients with a prior history of implantable collamer lens (ICL) implantation who underwent cataract extraction (CE). A secondary aim was to investigate the relationship between vault height and the rate of cataract development. Methods: Visual acuity and refraction measurements were collected after CE at one week, one month and six months. Vault height measurements were correlated to the time until symptomatic cataracts were removed. Results: A total of 44 eyes were analyzed at six months after CE with efficacy and safety indexes of 1.20 ± 1.11 and 1.50 ± 1.06, respectively. In addition, 70% of eyes had a post-operative uncorrected distance visual acuity (UDVA) within one line of pre-operative corrected distance visual acuity (CDVA). Refractive predictability at six months demonstrated that 43% and 69% of eyes were within ±0.25 D and ±0.50 D of SEQ target, respectively. Astigmatism measured by refractive cylinder was ≤0.25 D in 17% and ≤0.50 D in 34% of eyes pre-operatively compared to 40% and 60% of eyes, respectively, at six months post-operatively. Vault heights one week after ICL (p < 0.0081) and one week before CE (p < 0.0154) demonstrated a positive linear regression with the time until CE. Conclusions: This sample population achieved favorable visual outcomes six months after CE, similar to six months after ICL implantation. Patients with a history of ICL implantation will similarly have a good visual prognosis after CE.