This paper presents an interface circuit for capacitive and inductive MEMS biosensors using an oscillator and a charge pump based frequency-to-voltage converter. Frequency modulation using a differential crossed coupled oscillator is adopted to sense capacitive and inductive changes. The frequency-to-voltage converter is designed with a negative feedback system and external controlling parameters to adjust the sensitivity, dynamic range, and nominal point for the measurement. The sensitivity of the frequency-to-voltage converter is from 13.28 to 35.96 mV/MHz depending on external voltage and charging current. The sensitivity ranges of the capacitive and inductive interface circuit are 17.08 to 54.4 mV/pF and 32.11 to 82.88 mV/mH, respectively. A capacitive MEMS based pH sensor is also connected with the interface circuit to measure the high acidic gastric acid throughout the digestive tract. The sensitivity for pH from 1 to 3 is 191.4 mV/pH with 550 μV pp noise. The readout circuit is designed and fabricated using the UMC 0.18 μm CMOS technology. It occupies an area of 0.18 mm 2 and consumes 11.8 mW.
27 March 2017 in ACS Applied Materials & Interfaces
This paper presents a low power, compact, and low-complexity pulse-width modulation-based interface circuit for capacitive MEMS sensors. The circuit is designed using a ring oscillator, an RC controlled pulse generator with highpass filter, and a self-tuning inverter comparator to produce pulse width, which is proportional to differential capacitance and independent of parasitic capacitance. The high-pass filter is utilized to reduce the bandwidth of noise sources. The circuit provides control over sensitivity, dynamic range, and nominal point for the capacitance measurement by selecting controlling parameters, such as resistance of the RC pulse generator, biasing voltage of the self-tuning inverter comparator, and a reference capacitor using digital control signals. The circuit provides high linearity with higher sensitivity and lower power consumption. The sensitivity of the circuit is 0.56 to 3.62 μs/pF depending on the controlling parameters. The maximum dynamic sensing range is 22 to 270 pF depending on the controlling parameters. The interface circuit is designed and fabricated using the United Microelectronics Corporation (UMC) 0.18-μm CMOS technology. It occupies an active area of 0.17 mm 2 and consumes 98 μW. A capacitive MEMS-based pressure sensor is also connected with the interface circuit to measure pressure throughout the digestive tract. The sensitivity for pressure from 101 to 200 kPa is 60 ns/kPa and from 50 to 101 kPa is 23 ns/kPa.
4 April 2017 in IEEE Journal of Biomedical and Health Informatics
This paper presents a wireless capsule microsystem to detect and monitor the pH, pressure, and temperature of the gastrointestinal tract in real time. This research contributes to the integration of sensors (microfabricated capacitive pH, capacitive pressure, and resistive temperature sensors), frequency modulation and pulse width modulation based interface IC circuits, microcontroller, and transceiver with meandered conformal antenna for the development of a capsule system. The challenges associated with the system miniaturization, higher sensitivity and resolution of sensors, and lower power consumption of interface circuits are addressed. The layout, PCB design, and packaging of a miniaturized wireless capsule, having diameter of 13 mm and length of 28 mm, have successfully been implemented. A data receiver and recorder system is also designed to receive physiological data from the wireless capsule and to send it to a computer for real-time display and recording. Experiments are performed in vitro using a stomach model and minced pork as tissue simulating material. The real-time measurements also validate the suitability of sensors, interface circuits, and meandered antenna for wireless capsule applications.
Continuous navigation information for medical insertion methods including wireless capsule endoscopy is an important feature to guide a medical instrument/object to the targeted location within a hollow organ or internal cavity of the patient in the best possible way. Also, an autonomous medical insertion or swallowable device with a self-contained navigation system would reduce the role of the high-level operator and hence reduce the human-factor mistake and risk of injury. The navigation techniques suggested for Wireless Capsule Endoscopy are image-based that are required to transfer and process a significant amount of data in real-time operation. This would increase the complexity of the system and would be more difficult in dark or liquid environments. A novel navigation system for Wireless Capsule Endoscopy/ordinary endoscopy that does not depend on any external source for operation and can handle the uncertainties of the path even in a dark or liquid environment (i.e. mucosa) of the human body is presented in this paper. The key element of the system is based on a capacitive-based pressure sensor array mounted on the capsule with the shape of semi-hemisphere. The place of each node is arranged to represent the variation in the latitude and the longitude of the travelling path. The system can acquire the required information to navigate the capsule in three-dimensional space and enhance the safety of the locomotion by monitoring the pressure between the capsule and the ambient environment. The system determines the variation of the path 180° in longitude and latitude with less than (<0.004%) percentage of error. Working algorithms for flexible and rigid environments are described in this paper.
Wearable sensor nodes have gained a lot of attention during the past few years as they can monitor and record people's physical parameters in real time. Wearable sensor nodes can promote healthy lifestyles and prevent the occurrence of potential illness or injuries. This paper presents a flexible wearable sensor system powered by an efficient solar energy harvesting technique. It can measure the subject's heartbeats using a photoplethysmography (PPG) sensor and perform activity monitoring using an accelerometer. The solar energy harvester adopts an output current based maximum power point tracking (MPPT) algorithm, which controls the solar panel to operate within its high output power range. The power consumption of the flexible sensor nodes has been investigated under different operation conditions. Experimental results demonstrate that wearable sensor nodes can work for more than 12 hours when they are powered by the solar energy harvester for 3 hours in the bright sunlight.