ArmAssist (AA), developed by TECNALIA, is a telerehabilitation platform aiming to help poststroke subjects maintain the rehabilitation of the upper limb at home. AA includes robotic modules with multiple sensors to train and measure the users’ voluntary movements. An assessment platform based on serious games is also included to not only engage the user but also perform automated evaluations of arm and hand function and their evolution over time. Moreover, AA facilitates at-home rehabilitation with limited remote supervision by the therapist. In the present article, the technical specifications and developments of AA are described. Additionally, a summary of the outcomes of a usability evaluation of AA is presented.
This paper presents the kinematic design and development of a two degree-of-freedom (2DOF) spherical 5-bar thumb exoskeleton to augment the finger individuating grasp exercise robot (FINGER) rehabilitation robot, which assists the index and middle fingers individually in naturalistic grasping. The thumb module expands the capabilities of FINGER, allowing for broader proprioceptive training and assessment of hand function. The design process started by digitizing thumb-grasping motions to the index and the middle fingers separately, recorded from multiple healthy subjects utilizing a motion capture system. Fitting spheres to trajectory data of each subject allowed normalization of all subjects' data to a common center and radius. A two-revolute joint serial-chain mechanism was synthesized (intermediate optimization step) to reach the normalized trajectories. Next, the two resulting grasping trajectories were spatially sampled as targets for the 2DOF spherical 5-bar synthesis. Optimization of the spherical 5-bar included symmetry constraints and cost-function penalties for poor manipulability. The resulting exoskeleton assists both flexion/extension and abduction/adduction of the thumb enabling a wide range of motions. Consistent with FINGER, the parallel structure of the spherical 5-bar places the actuators at the base of the module, allowing for desirable characteristics, including high backdrivability, high controllable bandwidth, and low mechanical impedance. The mechanical design was developed from the kinematic solution, including an adjustable thumb cuff to accommodate different hand sizes. Fit and function of the device were tested on multiple subjects, including survivors of stroke. A proportional-derivative force controller with gravity and friction compensation was implemented to reduce resistance to motion during subject testing.
The rise of rehabilitation robotics has ignited a global investigation into the human machine interface (HMI) between device and user. Previous research on wearable robotics has primarily focused on robotic kinematics and controls but rarely on the actual design of the physical HMI (pHMI). This paper presents a data-driven statistical forearm surface model for designing a forearm orthosis in exoskeleton applications. The forearms of 6 subjects were 3D scanned in a custom-built jig to capture data in extreme pronation and supination poses, creating 3D point clouds of the forearm surface. Resulting data was characterized into a series of ellipses from 20 to 100% of the forearm length. Key ellipse parameters in the model include: normalized major and minor axis length, normalized center point location, tilt angle, and circularity ratio. Single-subject (SS) ellipse parameters were normalized with respect to forearm radiale-stylion (RS) length and circumference and then averaged over the 6 subjects. Averaged parameter profiles were fit with 3rd-order polynomials to create combined-subjects (CS) elliptical models of the forearm. CS models were created in the jig as-is (CS1) and after alignment to ellipse centers at 20 and 100% of the forearm length (CS2). Normalized curve fits of ellipse major and minor axes in model CS2 achieve R2 values ranging from 0.898 to 0.980 indicating a high degree of correlation between cross-sectional size and position along the forearm. Most other parameters showed poor correlation with forearm position (0.005 < R2 < 0.391) with the exception of tilt angle in pronation (0.877) and circularity in supination (0.657). Normalized RMSE of the CS2 ellipse-fit model ranged from 0.21 to 0.64% of forearm circumference and 0.22 to 0.46% of forearm length. The average and peak surface deviation between the scaled CS2 model and individual scans along the forearm varied from 0.56 to 2.86 mm (subject averages) and 3.86 to 7.16 (subject maximums), with the peak deviation occurring between 45 and 50% RS length. The developed equations allow reconstruction of a scalable 3D model that can be sized based on two user measures, RS length and forearm circumference, or based on generic arm measurements taken from existing anthropometric databases.
Arm and hand function play a critical role in the successful completion of everyday tasks. Lost function due to neurological impairment impacts millions of lives worldwide. Despite improvements in the ability to assess and rehabilitate arm deficits, knowledge about underlying sources of impairment and related sequela remains limited. The comprehensive assessment of function requires the measurement of both biomechanics and neuromuscular contributors to performance during the completion of tasks that often use multiple joints and span three-dimensional workspaces. To our knowledge, the complexity of movement and diversity of measures required are beyond the capabilities of existing assessment systems. To bridge current gaps in assessment capability, a new exoskeleton instrument is developed with comprehensive bilateral assessment in mind. The development of the BiLateral Upper-limb Exoskeleton for Simultaneous Assessment of Biomechanical and Neuromuscular Output (BLUE SABINO) expands on prior iterations toward full-arm assessment during reach-and-grasp tasks through the development of a dual-arm and dual-hand system, with 9 active degrees of freedom per arm and 12 degrees of freedom (six active, six passive) per hand. Joints are powered by electric motors driven by a real-time control system with input from force and force/torque sensors located at all attachment points between the user and exoskeleton. Biosignals from electromyography and electroencephalography can be simultaneously measured to provide insight into neurological performance during unimanual or bimanual tasks involving arm reach and grasp. Design trade-offs achieve near-human performance in exoskeleton speed and strength, with positional measurement at the wrist having an error of less than 2 mm and supporting a range of motion approximately equivalent to the 50th-percentile human. The system adjustability in seat height, shoulder width, arm length, and orthosis width accommodate subjects from approximately the 5th-percentile female to the 95th-percentile male. Integration between precision actuation, human–robot-interaction force-torque sensing, and biosignal acquisition systems successfully provide the simultaneous measurement of human movement and neurological function. The bilateral design enables use with left- or right-side impairments as well as intra-subject performance comparisons. With the resulting instrument, the authors plan to investigate underlying neural and physiological correlates of arm function, impairment, learning, and recovery.
5 July 2024 in IEEE Transactions on Medical Robotics and Bionics
This study aims to document the design of the OTHER Hand: a novel bilateral, reconfigurable, hand exoskeleton with opposable thumbs for use with upper limb exoskeletons. Intended for grasp research and rehabilitation with an emphasis on stroke, the OTHER Hand is designed as a one-size-fits-all system that can enable most of the common prehensile grasps and hand postures performed in activities of daily living. The capacity of the system to perform such grasps and postures is experimentally demonstrated by an average 94% normalized Grasping Ability Score across thirteen subjects using the Anthropomorphic Hand Assessment Protocol. This score demonstrates near-unhindered grasping performance for individuals without hand impairments wearing the OTHER Hand.
About Me
Assistive Robotics Researcher and Assistive Professor of Mechanical Engineering at University of Idaho.
Assistive Robotics Researcher and Assistive Professor of Mechanical Engineering at University of Idaho.