Shengxuan Zu

Mr. Shengxuan Zu

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2023 in Electronics
Verified
Journal Article
Open access
PDF file
GWGuanjian Wang
Guanjian Wang
LWLinong Wang
Linong Wang
SWshaocheng Wu
shaocheng Wu
SZShengxuan Zu
Shengxuan Zu
BSBin Song
Bin Song
Automated extraction of key points from three-dimensional (3D) point clouds in transmission corridors provides technical support for digital twin construction and risk management of the power grid. However, accurately and efficiently segmenting the point clouds of transmission corridors remains a challenging problem. Traditional segmentation methods for transmission corridors suffer from low accuracy and poor generalization ability, and the potential of deep learning in this field has been overlooked. Therefore, the PointNet++ deep learning model is employed as the backbone network for the segmentation of 3D point clouds in transmission corridors. Additionally, given the distinct distribution of key components, an end-to-end CA-PointNet++ architecture is proposed by integrating the Coordinate Attention (CA) module with PointNet++. This approach captures long-distance spatial contextual features and improves feature saliency for more precise segmentation. Furthermore, CA-PointNet++ is evaluated on a dataset of 3D point clouds collected by unmanned aerial vehicles (UAV) equipped with Light Detection and Ranging (LiDAR) for inspecting transmission corridors. The results show that CA-PointNet++ achieved 93.7% overall accuracy (OA) and 67.4% mean Intersection over Union (mIoU). Comparative studies with established deep learning models confirm that our proposed CA-PointNet++ exhibits high accuracy and strong generalization ability for point cloud segmentation tasks in transmission corridors.

8 February 2025 in Electronics
Verified
Journal Article
Open access
PDF file
LLLi Lu
Li Lu
LWLinong Wang
Linong Wang
SWshaocheng Wu
shaocheng Wu
SZShengxuan Zu
Shengxuan Zu
YAYuhao Ai
Yuhao Ai
BSBin Song
Bin Song
Accurate and efficient segmentation of key categories of transmission line corridor point clouds is one of the prerequisite technologies for the application of transmission line drone inspection. However, current semantic segmentation methods are limited to a few categories, involve cumbersome processes, and exhibit low accuracy. To address these issues, this paper proposes EMAFL-PTv3, a deep learning model for semantic segmentation of transmission line corridor point clouds. Built upon Point Transformer v3 (PTv3), EMAFL-PTv3 integrates Efficient Multi-Scale Attention (EMA) to enhance feature extraction at different scales, incorporates Focal Loss to mitigate class imbalance, and achieves accurate segmentation into five categories: ground, ground wire, insulator string, pylon, and transmission line. EMAFL-PTv3 is evaluated on a dataset of 40 spans of transmission line corridor point clouds collected by a drone in Wuhan and Xiangyang, Hubei Province. Experimental results demonstrate that EMAFL-PTv3 outperforms PTv3 in all categories, with notable improvements in the more challenging categories: insulator string (IoU 67.25%) and Pylon (IoU 91.77%), showing increases of 7.06% and 11.39%, respectively. The mIoU, mA, and OA scores reach 90.46%, 92.86%, and 98.07%, representing increases of 5.49%, 2.75%, and 2.44% over PTv3, respectively, proving its superior performance.

6 March 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SWshaocheng Wu
shaocheng Wu
LWLinong Wang
Linong Wang
GWGuanjian Wang
Guanjian Wang
SZShengxuan Zu
Shengxuan Zu
JGJiachen Gao
Jiachen Gao
BSBin Song
Bin Song
Traditional live-line work often relies on experience and manual labour. At present, the safety assessment of live-line work scenes adopts unified standards. However, due to the complexity of live-line work scenes, the unified standard cannot accurately measure and evaluate its safety. To address these issues, this article proposes a new method for identifying the hazardous areas in live-line work scenes. The proposed method consists of 2 parts. Firstly, PointMGA, whose baseline model is PointNet++, is proposed to segment the point clouds of the transmission scenes. The experimental results demonstrate that the PointMGA achieves higher segmentation accuracy compared to both the PointNet++ model and PointNet segmentation models. Specifically, our method achieved an overall accuracy of 99.1% and 99.5% on the validation and testing sets, respectively, with a Mean Intersection over Union (MIoU) of 96.7% and 99.7%. The second part of the method involves using the Farthest Point Sampling- Bisection Region Growing (FPS-BRG) distance algorithm to calculate the hazardous areas within the specific transmission scenes. This algorithm ensures accuracy and significantly improves computational efficiency by over 8 times. The results demonstrate the effectiveness of the approach in enhancing the automation and safety of live-line work in complex transmission scenes.

1 August 2024 in Electronics
Verified
Journal Article
Open access
PDF file
SZShengxuan Zu
Shengxuan Zu
LWLinong Wang
Linong Wang
SWshaocheng Wu
shaocheng Wu
GWGuanjian Wang
Guanjian Wang
BSBin Song
Bin Song
Reconstructing three-dimensional (3D) models of power equipment plays an increasingly important role in advancing digital twin power grids. To reconstruct a high-precision model, it is crucial to accurately obtain the pylon type and its necessary parameter information before modeling. This study proposes an improved method for identifying pylon types based on similarity measurement and a linearly transformed dataset. It begins by simplifying the identification of point clouds using the pylon shape curve. Subsequently, the resemblance between the curve and those curves within the dataset is evaluated using a similarity measurement to determine the pylon type. A novel method is proposed for calculating the characteristic parameters of the pylon point clouds. The horizontal and vertical distribution characteristics of the pylon point clouds are analyzed to identify key segmentation positions based on their types. Feature points are derived from key segmentation positions to calculate the characteristic parameters. Finally, the pylon 3D models are reconstructed on the basis of the calculated values. The experimental results showed that, compared with other similarity measurements, the Hausdorff distance had the best effect as a similarity measurement using the linearly transformed dataset, with an overall evaluation F-score of 86.4%. The maximum relative error of the calculated pylon parameters did not exceed 5%, affirming the feasibility of the algorithm.

7 July 2025 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
SWshaocheng Wu
shaocheng Wu
LWLinong Wang
Linong Wang
ZZZisheng Zeng
Zisheng Zeng
SZShengxuan Zu
Shengxuan Zu
BSBin Song
Bin Song
JGJiachen Gao
Jiachen Gao
Breakdown voltage prediction for air gaps is a crucial topic in high-voltage insulation research. Building upon existing studies and fundamental theories, the authors identify the gap configuration as the root cause influencing breakdown voltage. In light of this, the authors propose a novel approach for mapping the gap configuration to the breakdown voltage. Firstly, the data structuring method is proposed to abstract the air gap configuration into a mathematical point set. Secondly, inspired by the strengths of Graph Neural Networks and Transformers, the authors introduce a hybrid model, the Point Graph Transformer, which enable the prediction of the breakdown voltage through the point set. This approach is applicable to different gap configurations and influencing factors. To improve prediction accuracy and facilitate comparative studies, the authors present tailored data augmentation and padding strategies. Specifically, focusing on air gaps with two-dimensional axisymmetric structures, comprehensive breakdown voltage prediction research and comparative studies are conducted. Furthermore, ablation study is conducted and analyzed. The results demonstrate that the method deliver accurate breakdown voltage predictions, outperforming other methods. Notably, the evaluation metrics for the test set achieve a Mean Relative Error of 7.25%, Maximum Relative Error of 14.83%, and R-square of 96.86%.