27 June 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YLYongxin Liu
Yongxin Liu
BSBin Song
Bin Song
LWLinong Wang
Linong Wang
JGJiachen Gao
Jiachen Gao
RXRihong Xu
Rihong Xu
The transformers work in a complex environment, which makes them prone to failure. Dissolved gas analysis (DGA) is one of the most important methods for oil-immersed transformers’ internal insulation fault diagnosis. In view of the high correlation of the same fault data of transformers, this paper proposes a new method for transformers’ fault diagnosis based on correlation coefficient density clustering, which uses density clustering to extrapolate the correlation coefficient of DGA data. Firstly, we calculated the correlation coefficient of dissolved gas content in the fault transformers oil and enlarged the correlation of the same fault category by introducing the amplification coefficient, and finally we used the density clustering method to cluster diagnosis. The experimental results show that the accuracy of clustering is improved by 32.7% compared with the direct clustering judgment without using correlation coefficient, which can effectively cluster different types of transformers fault modes. This method provides a new idea for transformers fault identification, and has practical application value.

26 June 2023 in Electronics
Verified
Journal Article
Open access
PDF file
GWGuanjian Wang
Guanjian Wang
LWLinong Wang
Linong Wang
SWshaocheng Wu
shaocheng Wu
SZShengxuan Zu
Shengxuan Zu
BSBin Song
Bin Song
Automated extraction of key points from three-dimensional (3D) point clouds in transmission corridors provides technical support for digital twin construction and risk management of the power grid. However, accurately and efficiently segmenting the point clouds of transmission corridors remains a challenging problem. Traditional segmentation methods for transmission corridors suffer from low accuracy and poor generalization ability, and the potential of deep learning in this field has been overlooked. Therefore, the PointNet++ deep learning model is employed as the backbone network for the segmentation of 3D point clouds in transmission corridors. Additionally, given the distinct distribution of key components, an end-to-end CA-PointNet++ architecture is proposed by integrating the Coordinate Attention (CA) module with PointNet++. This approach captures long-distance spatial contextual features and improves feature saliency for more precise segmentation. Furthermore, CA-PointNet++ is evaluated on a dataset of 3D point clouds collected by unmanned aerial vehicles (UAV) equipped with Light Detection and Ranging (LiDAR) for inspecting transmission corridors. The results show that CA-PointNet++ achieved 93.7% overall accuracy (OA) and 67.4% mean Intersection over Union (mIoU). Comparative studies with established deep learning models confirm that our proposed CA-PointNet++ exhibits high accuracy and strong generalization ability for point cloud segmentation tasks in transmission corridors.

5 September 2018 in Energies
Verified
Journal Article
Open access
PDF file
ELEnwen Li
Enwen Li
LWLinong Wang
Linong Wang
BSBin Song
Bin Song
SJSiliang Jian
Siliang Jian
Dissolved gas analysis (DGA) of the oil allows transformer fault diagnosis and status monitoring. Fuzzy c-means (FCM) clustering is an effective pattern recognition method, but exhibits poor clustering accuracy for dissolved gas data and usually fails to subsequently correctly classify transformer faults. The existing feasible approach involves combination of the FCM clustering algorithm with other intelligent algorithms, such as neural networks and support vector machines. This method enables good classification; however, the algorithm complexity is greatly increased. In this paper, the FCM clustering algorithm itself is improved and clustering analysis of DGA data is realized. First, the non-monotonicity of the traditional clustering membership function with respect to the sample distance and its several local extrema are discussed, which mainly explain the poor classification accuracy of DGA data clustering. Then, an exponential form of the membership function is proposed to obtain monotony with respect to distance, thereby improving the dissolved gas data clustering. Likewise, a similarity function to determine the degree of membership is derived. Test results for large datasets show that the improved clustering algorithm can be successfully applied for DGA-data-based transformer fault detection.

23 July 2020 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
JGJiachen Gao
Jiachen Gao
LWLinong Wang
Linong Wang
ZLZhangxiang Lian
Zhangxiang Lian
GLGuanlin Li
Guanlin Li
YFYaqi Fang
Yaqi Fang
BSBin Song
Bin Song
Phase‐to‐phase air gap is a type of external insulation in power transmission and transformation projects. The dielectric strength of phase‐to‐phase air gaps affects the safety and reliability of power systems. Currently, in the external insulation design of power transmission and transformation projects, discharge tests are mainly used to obtain the dielectric strength of air gaps. Due to the lack of reasonable prediction model of dielectric strength, the design of the tests is not reasonable enough, which are time consuming and costly. In order to solve the problem, an engineering model of dielectric strength in phase‐to‐phase air gaps was proposed in this study. The engineering model could predict the dielectric strength in phase‐to‐phase air gaps by finite‐element method simulation and numerical calculation. In this study, the engineering model was applied in ultra high voltage (UHV) substations and UHV compact transmission lines to predict the dielectric strength of tubular busbar phase‐to‐phase air gaps and conductor phase‐to‐phase air gaps. The predicted results were in good agreement with discharge test results, and the errors were <6%, which proved the engineering model has certain applicability in power transmission and transformation projects.

28 August 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
JGJiachen Gao
Jiachen Gao
TDTongshu Ding
Tongshu Ding
YFYaqi Fang
Yaqi Fang
KLKai Liu
Kai Liu
SWshaocheng Wu
shaocheng Wu
ACAndrea Cavallini
Andrea Cavallini
Long air gaps containing a floating conductor are common in transmission and substation projects. As the floating electrode moved across the gap, the lowest breakdown voltage area (LBA) can be observed. In this article, an experimental platform for observing and measuring discharges in rod-rod-plane air gaps is used to investigate the discharge mechanism in the LBA. The results indicate that the existence of the LBA is related to the minimum voltage for the discharge channel formation in sub-gap 1 (facing the high-voltage rod) and the breakdown voltage of sub-gap 2 (facing the grounded plane). When the floating electrode is closer to the high-voltage electrode than the LBA, the breakdown voltage is increased because the potential of the floating electrode does not reach the breakdown voltage of sub-gap 2 at the time the discharge short circuits sub-gap 1. When the floating electrode is further away from the high-voltage electrode than the LBA, the breakdown voltage is increased because the discharge channel formation in sub-gap 1 requires a higher voltage. The LBA corresponds to the area where these two different phenomena can happen with minimum voltage. The results can contribute to modeling the discharge of a long air gap containing a floating conductor.

12 December 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JGJiachen Gao
Jiachen Gao
LWLinong Wang
Linong Wang
QZQiushi Zhang
Qiushi Zhang
BSBin Song
Bin Song
Positive switching impulse discharge characteristics are an important basis for the external insulation design of transmission line towers. At present, the characteristics are obtained mainly by real tower discharge tests. Since the existing research on the discharge model is not perfect, test designs are not reasonable, which results in high costs. The influence of line height and tower width on the discharge characteristics of Ultra High Voltage (UHV) transmission lines air gaps is studied in this paper. The results show that the line height had little influence on the breakdown voltage of air gaps in UHV transmission lines. A tower-width discharge model was obtained by fitting the breakdown voltage of air gaps with different gap lengths and tower widths. By analyzing the gap characteristic factors of different transmission lines, a discharge model of different tower air gaps in UHV transmission lines was presented. The breakdown voltage calculated by the models was in good agreement with the test results, and the errors were not more than 5%.