Marco Antonio Aguirre Camacho

Mx. Marco Antonio Aguirre Camacho

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
Papa Pio Ascona GarcíaPapa Pio Ascona García
Papa Pio Ascona García
GOGUIDO ELAR ORDOÑEZ
GUIDO ELAR ORDOÑEZ
WZWilmer Moisés Zelada Zamora
Wilmer Moisés Zelada Zamora
MCMarco Antonio Aguirre Camacho
Marco Antonio Aguirre Camacho
WPWilmer Rojas Pintado
Wilmer Rojas Pintado
NFNilthon Arce Fernández
Nilthon Arce Fernández
Crack formation and rehabilitation of concrete elements, such as slabs and columns, in buildings located in areas with temperatures above 25 °C, where accelerated water evaporation significantly reduces their structural strength, was addressed. To mitigate this effect, an intelligent automated monitoring and curing system was developed, using integrated sensors and embedded controllers. The study was applied, experimental and explanatory, based on the hypothetico-deductive method. Work was carried out with physical models (specimens, columns and solid slabs) with 1:2:3 dosage, in which thermal and humidity sensors were integrated, and a visualisation system with an LCD screen was designed in Proteus for data collection. Quantitative analysis, with 95 % confidence, revealed a moderate and significant correlation (r = 0.587; p = 0.001) between the environmental thermo-hygrometer and the embedded DS18B20 sensor, showing effective heat transfer. The low correlation with the HD-38 sensor (r = 0.143; p = 0.468) indicated little influence of ambient humidity on internal humidity. The system restored the initial screams, used 1680 litres of water in 28 days, reducing consumption by 20 % compared to traditional methods. Higher evaporation was identified between 11:00 and 16:00 hours (UTC-5), a critical phenomenon not reported in previous studies in tropical areas.

3 July 2025 in Technologies
Verified
Journal Article
Open access
PDF file
Papa Pio Ascona GarcíaPapa Pio Ascona García
Papa Pio Ascona García
GOGUIDO ELAR ORDOÑEZ
GUIDO ELAR ORDOÑEZ
WZWilmer Moisés Zelada Zamora
Wilmer Moisés Zelada Zamora
MCMarco Antonio Aguirre Camacho
Marco Antonio Aguirre Camacho
WPWilmer Rojas Pintado
Wilmer Rojas Pintado
NFNilthon Arce Fernández
Nilthon Arce Fernández
This study addresses the formation, detection, and repair of cracks in concrete elements exposed to temperatures above 25 °C, where accelerated evaporation compromises their structural strength. An automated intelligent curing system with embedded sensors (DS18B20, HD-38) and Arduino controllers was developed and applied to solid slabs, columns, and concrete test specimens (1:2:3.5 mix ratio). The electronic design was simulated in Proteus and validated experimentally under tropical conditions. Data with normal distribution (p > 0.05) showed a significant correlation between internal and ambient temperature (r = 0.587; p = 0.001) and a low correlation in humidity (r = 0.143; p = 0.468), indicating hygrometric independence. The system healed cracks of 0.01 mm observed two hours after pouring the mixture, associated with an evaporation rate of 1.097 mL/s in 4 m2. For 28 days, automated irrigation cycles were applied every 30 to 60 min, with a total of 1680 L, achieving a 20% reduction in water consumption compared to traditional methods. The system maintained stable thermal conditions in the concrete despite ambient temperatures of up to 33.85 °C. A critical evaporation range was identified between 11:00 and 16:00 (UTC-5). The results demonstrate the effectiveness of the embedded system in optimizing curing, water efficiency, and concrete durability.

14 July 2025 in Sapienza: International Journal of Interdisciplinary Studies
Verified
Journal Article
Open access
PDF file
LNLilian Rocio Rimapa Navarro
Lilian Rocio Rimapa Navarro
MTMerly Enith Mego Torres
Merly Enith Mego Torres
EHErlith Tafur Huaman
Erlith Tafur Huaman
MCMarco Antonio Aguirre Camacho
Marco Antonio Aguirre Camacho
LCLiliana del Carmen Suárez Santa Cruz
Liliana del Carmen Suárez Santa Cruz
PCPedro Julián Ormeño Carmona
Pedro Julián Ormeño Carmona
Objective: to test the safety and health nexus in the labor rights of women workers in the Peruvian Public Sector. Theoretical framework: Based on human capital theories, resource-based view of the company, and labor rights theory, focusing on the physical, mental and social well-being of women workers in the Peruvian public sector. Methodology: Non-experimental, descriptive and correlational study, using mixed quantitative and qualitative methods. It includes a 32-item survey and structured interviews with workers and labor law experts. Results: Positive correlation between occupational safety and health with labor rights and paid breaks. Occupational psychology shows a strong correlation with all variables, while occupational medicine shows no significant correlations. Conclusions: The study showed the vital role of legal compliance, work psychology, and comprehensive safety measures in improving occupational health and worker well-being. Further investigation into psychosocial factors and sector-specific risks is needed to refine safety practices.

28 May 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
Papa Pio Ascona GarcíaPapa Pio Ascona García
Papa Pio Ascona García
MCMarco Antonio Aguirre Camacho
Marco Antonio Aguirre Camacho
ECEmerson Julio Cuadros-Rojas
Emerson Julio Cuadros-Rojas
In the provinces of the region, empirical constructions reached maximum points with these practices. The effects and pathologies appear as physical, chemical and mechanical failures in pillars, walls and roofs, generating uncertainty for the user. The current powerful design can detect the interior deterioration of coatings in adobe, brick and concrete constructions, and prevent collapses, material and economic losses. Experimental methods performed affirm the serious validity. The accuracy of the simulation and design provide a pre-test reliability of 95%. Five piles constructed of various materials participate in the prototype performance test, there is a correlation (R=0.9997) between the magnetic field range "B" (cm) and density "ρ" (g/cm³), also by increasing the current (i) in transit Q1 and coil L1, the induction of the "B" increases proportionally until penetrating the density of the wall of the building, having 5% reading error.

20 July 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Papa Pio Ascona GarcíaPapa Pio Ascona García
Papa Pio Ascona García
MCMarco Antonio Aguirre Camacho
Marco Antonio Aguirre Camacho
EBElger Orlando Silva Barboza
Elger Orlando Silva Barboza
GOGUIDO ELAR ORDOÑEZ
GUIDO ELAR ORDOÑEZ
ECEmerson Julio Cuadros-Rojas
Emerson Julio Cuadros-Rojas
The aim of this study was to develop a sustainable electromagnetic prototype to detect the interior deterioration of walls in buildings in order to mitigate uncertainty as it is a challenge to observe the interior state of walls without utilising destructive procedures. The method used was experimental, developmental and quantitative in its approach. The inductance, electric current, modulated frequency and power of the electromagnetic field were used to penetrate the constructed specimens, which were built of materials such as concrete, brick, adobe, plaster and fine sand and had walls with a thickness of less than 300 millimetres. The results show that the optimum value of the magnetic field was 0.18 µT, which was sufficient to penetrate 150 mm with densities between 1.0 and 2.4 g/cm3 and porosities between 11 and 60%. The current and wave each had a coefficient of determination R2 = 0.8914, and the average inductance value was 184 µH, which was established with an air core of radius 9.75 cm and with 19 turns with AWG-25 wire. The frequency-modulated signal ranged in the audible zone between 10 and 22 kHz. The presented prototype detects the interior deterioration of the walls of the building, and the signal is reflected on a metallic guide on the opposite side of the wall with a reading error of 5%. The use of this prototype does not represent a risk to the operator or the environment.