Ken Sasaki

Prof. Ken Sasaki


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2021 in Electronics
Verified
Journal Article
Open access
PDF file
Dairoku MuramatsuDairoku Muramatsu
Dairoku Muramatsu
KSKen Sasaki
Ken Sasaki
As society ages, wireless body area networks (WBANs) are expected to increasingly improve the quality of life of the elderly and disabled. One promising WBAN technology is human body communication (HBC), which utilizes part of the human body as a transmission medium. Communication between head-mounted wearable devices, such as hearing aids, is a potential HBC application. To clarify the HBC transmission mechanism between head-mounted wearable devices, this study analyzes the input impedance characteristics of the transceiver electrodes, transmission characteristics, and electric field distributions around and through a detailed head model. The investigation was performed via an electromagnetic field simulation. The signal frequency had less effect on the transmission characteristics and electric field distributions at 10, 20, and 30 MHz. However, the transmission mechanism between the head-mounted wearable devices was influenced by the number of electrodes in the transceiver. Moreover, the transmission characteristics between two-electrode transceivers were improved by impedance matching. Finally, the availability of the proposed system was evaluated from power consumption and human safety perspectives.

12 May 2021 in Electronics
Verified
Journal Article
Open access
PDF file
Dairoku MuramatsuDairoku Muramatsu
Dairoku Muramatsu
KSKen Sasaki
Ken Sasaki
In human body communication (HBC) systems, radio-frequency signals are excited in the human body through a wearable antenna comprised of electrodes that are in contact with the surface of the body. The input impedance characteristics of these antennas are important design parameters for increasing transmission efficiency and reducing signal reflection, similar to other wireless circuits. In this study, we discuss variations of input impedance characteristics of a wearable antenna prototype caused by differences among real human subjects. A realistic human arm model is used for simulations, and the analytical results obtained are compared to measured data obtained from real human subjects, in a range from 1 to 100 MHz. The simulations of input impedance characteristics from antennas worn on the wrists of male and female models with dry and wet skin conditions show that the impedance variation between genders is small. The moisture condition of the skin has little influence on frequencies exceeding several MHz. Measurements with a proto-type wearable antenna and 22 real human subjects reveal that HBC is robust against the variations of individual users from the viewpoint of the voltage standing wave ratio. Moreover, a simplified rectangular prism model is proposed to analyze the thickness of body tissues. Comparisons of measured input impedances indicate that individual differences in impedance are mainly due to differences in the thickness of skin and fat layers. The model also enables us to design the antenna prototype without multiple subject experiments.

3 September 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KYKentaro Yamamoto
Kentaro Yamamoto
YNYoshifumi Nishida
Yoshifumi Nishida
KSKen Sasaki
Ken Sasaki
Dairoku MuramatsuDairoku Muramatsu
Dairoku Muramatsu
FKFukuro Koshiji
Fukuro Koshiji
Human body communication (HBC) is a wireless communication method that uses the human body as part of the transmission medium. Electrodes are used instead of antennas, and the signal is transmitted by the electric current through the human body and by the capacitive coupling outside the human body. In this study, direction of electric field lines and direction of electric current through the human body were analyzed by the finite-difference time-domain method to clarify the signal path, which is not readily apparent from electric field strength distribution. Signal transmission from a transmitter on the subject’s wrist to an off-body receiver touched by the subject was analyzed for two types of transmitter electrode settings. When both the signal and ground electrodes were put in contact with the human body, the major return path consisted of capacitive coupling between the receiver ground and the human body, and the electric current through the human body that flowed back to the ground electrode of the transmitter. When the ground electrode was floating, the only return path was through the capacitive coupling of the floating ground. These results contribute to the better understanding of signal transmission mechanism of HBC and will be useful for developing HBC applications.

25 January 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
NANaruto Arai
Naruto Arai
YTYohei Toriumi
Yohei Toriumi
KOKen Okamoto
Ken Okamoto
JKJun Kato
Jun Kato
YAYoshiharu Akiyama
Yoshiharu Akiyama
KSKen Sasaki
Ken Sasaki
Conducted noise originating from power supply equipment disrupts telecommunication networks, causing problems such as telecommunication interruptions and reduction in the speed of communication. Measurement of noise in data transmission lines at a repair site may require additional work to secure the electrical ground level for the measurement, because the data lines are differential pairs and the ground level is not always accessible. A method to estimate the capacitance between the measurement equipment and the ground was developed to allow measurement without access to the ground, i.e., in floating conditions. The method uses an oscillator and multiple electrodes to measure the capacitive coupling with the ground under the floor. A ground-capacitance-estimating device was fabricated and tested. Its accuracy was further improved by incorporating a linear function to express the relationship between the output of the device and the known ground capacitance in the calibration setting. This calibration procedure and the measurement procedure at the repair site are described. The noise voltage was calculated from the estimated ground capacitance and the voltage reading of the floating measurement equipment. The estimated ground capacitance was in the order of several tens of pF. The error of the corrected noise voltage was within 1.6 dB.

1 May 2022 in IEEJ Transactions on Electronics, Information and Systems
Verified
Journal Article
Closed access
PDF file
Dairoku MuramatsuDairoku Muramatsu
Dairoku Muramatsu
KSKen Sasaki
Ken Sasaki
Electromagnetic phantom is widely used to develop technologies based on the interaction between human and electromagnetic waves. In this paper, we evaluated the emulation performance of a multilayered HF-band phantom from the viewpoint of bioimpedance. The comparison among the measurements using multilayered/muscle phantom and the simulation using detailed arm model showed that the multilayered phantom could emulate the bioimpedance accurately.