Respiratory motion estimation is an important part in image-guided radiation therapy and clinical diagnosis. However, most of the respiratory motion estimation methods rely on indirect measurements of external breathing indicators, which will not only introduce great estimation errors, but also bring invasive injury for patients. In this paper, we propose a method of lung respiratory motion estimation based on fast Kalman filtering and 4D CT image registration (LRME-4DCT). In order to perform dynamic motion estimation for continuous phases, a motion estimation model is constructed by combining two kinds of GPU-accelerated 4D CT image registration methods with fast Kalman filtering method. To address the high computational requirements of 4D CT image sequences, a multi-level processing strategy is adopted in the 4D CT image registration methods, and respiratory motion states are predicted from three independent directions. In the DIR-lab dataset and POPI dataset with 4D CT images, the average target registration error (TRE) of the LRME-4DCT method can reach 0.91 mm and 0.85 mm respectively. Compared with traditional estimation methods based on pair-wise image registration, the proposed LRME-4DCT method can estimate the physiological respiratory motion more accurately and quickly. Our proposed LRME-4DCT method fully meets the practical clinical requirements for rapid dynamic estimation of lung respiratory motion.
6 August 2021 in International Journal of Imaging Systems and Technology
In the fields of microseismic monitoring and deep earth exploration, low-frequency signal detection faces problems such as weak vibration signals, large ambient temperature changes, and complex ambient noise. A novel comprehensive low-frequency response extension method for a moving coil geophone is proposed to implement a high-sensitivity low-frequency vibration sensor with low noise floor for measuring seismic wave velocity. Based on exploring the principle of increasing the damping ratio of geophone to expand the linear variation range of acceleration with frequency, a model in which both damping and gain vary with temperature is established by introducing the temperature-dependent coil resistance parameter. Developed on the typical negative impedance conversion method, a damping adjustment circuit with temperature compensation, gain adjustment and differential noise suppression is designed comprehensively, thereby a new scheme of low-frequency response extension based on the force balance principle is proposed. To further suppress the inherent 1/f noise of the operational amplifier in the low frequency band, an acceleration-velocity conversion scheme based on a dual operational amplifier narrowband filter is designed to flatten the velocity-frequency curve while suppressing low-frequency noise. Through standard vibration table and field comparative tests, the proposed comprehensive low-frequency extension method not only extends the natural frequency of the conventional moving coil detector from 5Hz to 0.25Hz, but also has low noise, high gain (sensitivity of 420V/(m·s⁻¹)) and high-temperature stability.