Enqing Dong

Dr. Enqing Dong


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2020 in Medical Physics
Verified
Journal Article
Closed access
PDF file
YFYu Fu
Yu Fu
PXPeng Xue
Peng Xue
HJHuizhong Ji
Huizhong Ji
WCWentao Cui
Wentao Cui
EDEnqing Dong
Enqing Dong

10 April 2017 in European Radiology
Verified
Journal Article
Closed access
PDF file
ZTZhenchao Tang
Zhenchao Tang
ZLZhenyu Liu
Zhenyu Liu
RLRuili Li
Ruili Li
XYXin Yang
Xin Yang
XCXingwei Cui
Xingwei Cui
JTJie Tian
Jie Tian

1 March 2019 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
ZTZhenchao Tang
Zhenchao Tang
XZXiao-Yan Zhang
Xiao-Yan Zhang
ZLZhenyu Liu
Zhenyu Liu
XLXiao-Ting Li
Xiao-Ting Li
YSYan-Jie Shi
Yan-Jie Shi
JTJie Tian
Jie Tian

26 August 2019 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
PXPeng Xue
Peng Xue
EDEnqing Dong
Enqing Dong
HJHuizhong Ji
Huizhong Ji
To solve the problem that traditional image registration methods based on continuous optimization for large motion lung 4D CT image sequences are easy to fall into local optimal solutions and lead to serious misregistration, a novel image registration method based on high-order Markov Random Field (MRF) is proposed. By analyzing the effect of the deformation field constraint of the potential functions with different order cliques in MRF model, energy functions with high-order cliques form are designed separately for 2D and 3D images to preserve topology of the deformation field. In order to preserve the topology of the deformation field more effectively, it is necessary to apply a smooth term and a topology preservation term simultaneously in the energy function and use logarithmic function to impose a penalty on the Jacobian matrix with high-order cliques in the topology preservation term. For the complexity of the designed energy function with high-order cliques form, Markov Chain Monte Carlo (MCMC) algorithm is used to solve the optimization problem of the designed energy function. To address the high computational requirements in lung 4D CT image registration, a multi-level processing strategy is adopted to reduce the space complexity of the proposed registration method and promotes the computational efficiency. In the DIR-lab dataset with 4D CT images and the COPD (Chronic Obstructive Pulmonary Disease) dataset with 3D CT images, the average target registration error (TRE) of our proposed method can reach 0.95mm respectively.

21 October 2022 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
YFYu Fu
Yu Fu
PXPeng Xue
Peng Xue
TXTaohui Xiao
Taohui Xiao
ZZZhili Zhang
Zhili Zhang
YZYouren Zhang
Youren Zhang
EDEnqing Dong
Enqing Dong
Achieving the pathological type diagnosis of pulmonary nodules on chest CT is a critical step in the early detection of lung cancer and treatment of patients. Based on a small and unbalanced self-constructed dataset, we achieved intelligent diagnosis of five pathological types including adenocarcinoma, squamous cell carcinoma, small cell carcinoma, inflammatory and other benign diseases for the first time. In order to reduce the dependence of deep convolutional neural network (DCNN) on a large amount of training data, a reverse adversarial classification network (RACN) was proposed based on semi-supervised learning, which consists of a reverse generative adversarial network (RGAN) for unsupervised regression and a supervised classification network (CN). In RGAN, five specific normal distributions P with different means and variances were assigned to represent the five pathological types, and then a special regression task was designed by mapping pulmonary nodules to the random sampling Z of P. The input of generator in RGAN is set to 3D nodule volume data, the inputs of discriminator are set to Z and the output of generator. The regression task enables RGAN to extract specific features, which will be deeply integrate into CN to improve the classification performance. Experiments showed that the average sensitivity of RACN in detecting malignant nodules was 0.6525, where the sensitivity of adenocarcinoma, small cell carcinoma and squamous cell carcinoma was 0.8426, 0.5604 and 0.5543. Besides, the RACN can achieve 93.21% accuracy for diagnosing malignant nodules on the public LIDC-IDRI dataset, obtaining the state-of-the-art results.

1 October 2021 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
YFYu Fu
Yu Fu
PXPeng Xue
Peng Xue
NLNing Li
Ning Li
PZPeng Zhao
Peng Zhao
ZXZhuodong Xu
Zhuodong Xu
EDEnqing Dong
Enqing Dong