Ren Yang

Dr. Ren Yang

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in Current Research in Food Science
Verified
Journal Article
Open access
RYRen Yang
Ren Yang
JGJiewen Guan
Jiewen Guan
SSSicheng Sun
Sicheng Sun
SSShyam Sablani
Shyam Sablani
JTJuming Tang
Juming Tang
Our recent studies and several publications suggest that the low water activity (aw) of oil in thermal processing might be a major contributing factor towards the increased thermal resistance of bacteria in oils. In this study, we developed a reliable method to measure the water activity of oil by measuring the equilibrium relative humidity in a small headspace. Using this method, water activity of peanut oil was found to decrease exponentially with increasing temperature. A model derived from excess Gibbs free energy was fitted to the observations with an R2 = 99.6% and RMSE = 0.01 (aw). Our results suggest that the sharply reduced water activity of oil resulting from a rise in temperature could cause desiccation of bacteria. This is a possible explanation for the protective effect of oil in thermal processing.

25 April 2022 in Food Research International
Verified
Journal Article
Closed access
RYRen Yang
Ren Yang
WLWei Lina
Wei Lina
JDJianwu Dai
Jianwu Dai
JTJuming Tang
Juming Tang

1 November 2020 in Food Research International
Verified
Journal Article
Closed access
RYRen Yang
Ren Yang
JXJie Xu
Jie Xu
SLStephen P. Lombardo
Stephen P. Lombardo
GGGirish M Ganjyal
Girish M Ganjyal
JTJuming Tang
Juming Tang

8 March 2024 in Food Control
Verified
Journal Article
Closed access
SZShuang Zhang
Shuang Zhang
RYRen Yang
Ren Yang
XZXu Zhou
Xu Zhou
YFYaohua Feng
Yaohua Feng
JTJuming Tang
Juming Tang

13 March 2024 in Food Control
Verified
Journal Article
Closed access
SSSicheng Sun
Sicheng Sun
RYRen Yang
Ren Yang
YXYucen Xie
Yucen Xie
MZMei-Jun Zhu
Mei-Jun Zhu
SSShyam Sablani
Shyam Sablani
JTJuming Tang
Juming Tang

1 July 2022 in Journal of Food Protection
Verified
Journal Article
Closed access
PDF file
RYRen Yang
Ren Yang
GFGregory J. Fleischman
Gregory J. Fleischman
ASArlette Shazer
Arlette Shazer
HLHaiping Li
Haiping Li
For bacteria with log-linear thermal inactivation kinetics in food, D-values are obtained in multiple isothermal inactivation experiments at different temperatures, and the z-value is obtained from these D-values. In a previous work, the cumulative lethality integral was mathematically solved in closed form when temperature in the food increased linearly with time. The solution revealed that each nonisothermal experiment could yield both D- and z-values, eliminating the need for getting multiple D-values to get a z-value. The present study reports on the first experimental implementation of this method of obtaining D- and z-values for Salmonella Senftenberg suspended in skim milk for which a differential scanning calorimeter (DSC) provided the required constant heating rate. The resulting D- and z-values were compared with those obtained from an isothermal method with capillary tubes. No significant differences in z-values were found between the two methods. The D-values also agreed but only after correcting the nonisothermal value for temperature lag in the DSC caused by the large sample size required. A 5 K/min heating rate was used in this comparison. Other rates were also investigated: 1, 3, 7.5, and 10 K/min. Although D- and z-values should be independent of DSC heating rate, heating rates of 1 and 10 K/min yielded values that were significantly different from the others; therefore, these rates cannot be recommended for use in this nonisothermal method.HIGHLIGHTSD- and z-values were experimentally obtained together for the first time.A published mathematical analysis was used for the first time to obtain D- and z-values.An off-the-shelf instrument (DSC) provided the heating protocol stipulated by the analysis.D- and z-values matched those obtained from the isothermal capillary tube method.The DSC had limitations for measuring D- and z-values.