Arlette Shazer

Arlette Shazer

Auto-generated profile, based on publicly available information

Arlette Shazer

Institute for Food Safety and Health, Illinois Institute of Technology, Bedford Park, Illinois 60501

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2022 in Journal of Food Protection
Verified
Journal Article
Closed access
PDF file
RYRen Yang
Ren Yang
GFGregory J. Fleischman
Gregory J. Fleischman
ASArlette Shazer
Arlette Shazer
HLHaiping Li
Haiping Li
For bacteria with log-linear thermal inactivation kinetics in food, D-values are obtained in multiple isothermal inactivation experiments at different temperatures, and the z-value is obtained from these D-values. In a previous work, the cumulative lethality integral was mathematically solved in closed form when temperature in the food increased linearly with time. The solution revealed that each nonisothermal experiment could yield both D- and z-values, eliminating the need for getting multiple D-values to get a z-value. The present study reports on the first experimental implementation of this method of obtaining D- and z-values for Salmonella Senftenberg suspended in skim milk for which a differential scanning calorimeter (DSC) provided the required constant heating rate. The resulting D- and z-values were compared with those obtained from an isothermal method with capillary tubes. No significant differences in z-values were found between the two methods. The D-values also agreed but only after correcting the nonisothermal value for temperature lag in the DSC caused by the large sample size required. A 5 K/min heating rate was used in this comparison. Other rates were also investigated: 1, 3, 7.5, and 10 K/min. Although D- and z-values should be independent of DSC heating rate, heating rates of 1 and 10 K/min yielded values that were significantly different from the others; therefore, these rates cannot be recommended for use in this nonisothermal method.HIGHLIGHTSD- and z-values were experimentally obtained together for the first time.A published mathematical analysis was used for the first time to obtain D- and z-values.An off-the-shelf instrument (DSC) provided the heating protocol stipulated by the analysis.D- and z-values matched those obtained from the isothermal capillary tube method.The DSC had limitations for measuring D- and z-values.

1 October 2017 in Journal of Food Protection
Verified
Journal Article
Closed access
ASA. Shazer
A. Shazer
DSDiana S. Stewart
Diana S. Stewart
KDKaiping Deng
Kaiping Deng
MTM. Tortorello
M. Tortorello
In fresh-cut produce production, antimicrobials may be used during washing to control the risk of cross-contamination by microbial hazards. Surrogate microorganisms have long been used to validate processes, but none have been identified for validating the efficacy of antimicrobial washing of fresh-cut produce. The objective of this study was to develop procedures by which surrogates may be identified for use in validating the control of cross-contamination for fresh-cut lettuce operations. Four microbial characteristics, which may be important factors in cross-contamination events, were quantitatively evaluated in potential surrogate microorganisms for comparison to a reasonably foreseeable hazard, Escherichia coli O157:H7: sensitivity to chlorine in solution, sensitivity to chlorine on lettuce leaf surfaces, shedding from contaminated lettuce leaves into the water during washing, and cross-contamination from inoculated to uninoculated lettuce leaves during chorine washing. A procedure of practi...

8 February 2022 in Journal of AOAC INTERNATIONAL
Verified
Journal Article
Closed access
PDF file
TFTong-Jen Fu
Tong-Jen Fu
NMNicole Maks
Nicole Maks
ASArlette G Shazer
Arlette G Shazer
CCChristina Chrysogelos
Christina Chrysogelos
Sprout growers in the United States are required to test spent sprout irrigation water (SSIW) or in-process sprouts for Escherichia coli O157:H7 and Salmonella species. Pathogen screening kits are commercially available; however, few have been validated for analysis of sprouts or SSIW. This study evaluated AOAC-certified test kits (lateral flow devices [LFDs], enzyme immunoassays [EIAs], and molecular assays) in comparison with culture methods described in the U.S. Food and Drug Administration (FDA) Bacteriological Analytical Manual (BAM) for detection of Salmonella and E. coli O157:H7 in alfalfa SSIW. Twenty-five milliliter aliquots of alfalfa SSIW, either uninoculated or inoculated with Salmonella or E. coli O157:H7 at a low (∼0.5–0.7 CFU/25 mL) or high level (∼10–20 CFU/25 mL), were subjected to the enrichment and assay protocols recommended by each test. Pathogen presence was confirmed following FDA BAM procedures and, if applicable, test kit manufacturer protocols. Twelve of the 13 Salmonella test kits evaluated (except VIDAS UP) performed well and detected Salmonella in 100% of SSIW samples contaminated at 0.61 CFU/mL. Performance varied among E. coli O157:H7 test kits, with four (Reveal, MicroSEQ, GDS, MDA) of 12 kits designed for next-day detection, and four (Reveal, VIP Gold, MicroSEQ, GDS) of seven kits designed for same-day detection capable of detecting the pathogen in 100% samples contaminated at 0.90 CFU/mL. Enrichment conditions play a key role in determining the performance of test kits and the success of confirmation. This study is the first to compare a wide range of commercial test kits for detection of Salmonella and E. coli O157:H7 in SSIW.

1 February 2022 in Journal of Food Engineering
Verified
Journal Article
Closed access
GFGregory J. Fleischman
Gregory J. Fleischman
RYRen Yang
Ren Yang
ASArlette Shazer
Arlette Shazer
HLHaiping Li
Haiping Li