Ovidiu Iorga

Dr. Ovidiu Iorga


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2023 in Polymers
Verified
Journal Article
Open access
PDF file
TRTraian Rotariu
Traian Rotariu
AMAndreea Elena Moldovan
Andreea Elena Moldovan
Gabriela ToaderGabriela Toader
Gabriela Toader
Aurel DiaconAurel Diacon
Aurel Diacon
Edina RusenEdina Rusen
Edina Rusen
Thomas M. KlapötkeThomas M. Klapötke
Thomas M. Klapötke
The increasingly harsher and more complex international and European environmental legislation drives the current development of “greener” energetics materials and munitions. The aerospace and defense industries rely on extensive research in the formulation and scale-up production of polymer-bonded explosives (PBX). In this context, this paper aims to present a versatile method for obtaining “green” PBX formulations based on two high explosives (hexogen (RDX) and octogen (HMX)) and acrylic acid—ethyl acrylate copolymeric binders. This study developed an innovative “eco-friendly” technology for coating the RDX and HMX crystals, allowing straightforward and safer manufacture of PBX, avoiding the use of traditional organic solvents. At the same time, these polymeric binders are soluble in water at a slightly alkaline pH and insoluble at acidic or neutral pH, thus ensuring a safer manipulation of the energetic materials during their entire life cycle and a facile recovery of the explosive in its original shape and morphology in demilitarization. The PBX formulations were characterized via specific analytical tools to evaluate the influence of their composition on the safety and performance characteristics: scanning electron microscopy (SEM), Fourier-transform infrared spectroscopy (FT-IR), alkaline pH solubility tests, differential thermal analysis (DTA), impact sensitivity test (BAM Fall Hammer Test), friction sensitivity test (BAM Friction Test), electrostatic sensitivity test (ESD), vacuum stability test, small scale shock reactivity test (SSRT), detonation velocity test. The “green” PBX formulations obtained through a simple and innovative coating method, based on the polymeric binders’ adjustable water solubility, demonstrated remarkable energetic performances and a facile recovery of the explosive crystals by the dissolution of the polymeric binder at pH 11 and 30 °C.

14 January 2022 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
RGRaluca Elena Ginghina
Raluca Elena Ginghina
Gabriela ToaderGabriela Toader
Gabriela Toader
Munizer PuricaMunizer Purica
Munizer Purica
ABAdriana-Elena Bratu
Adriana-Elena Bratu
CLClaudiu Lazaroaie
Claudiu Lazaroaie
Cosmin RomanitanCosmin Romanitan
Cosmin Romanitan
The present work reveals a comprehensive decontamination study on real and simulated biological and chemical warfare agents (BCWA). The emphasis was on evaluating the antimicrobial activity against real biological warfare agents, such as Bacillus anthracis, and also the capacity of neutralizing real chemical warfare agents, such as mustard gas or soman, by employing three different types of organic solutions enriched with ZnO, TiO2, and zeolite nanoparticles, specially designed for decontamination applications. The capacity of decontaminating BCWA was evaluated through specific investigation tools, including surface monitoring with the swabs method, minimum inhibitory (MIC) and minimum bactericidal concentration (MBC) evaluations, time-kill tests for microorganisms, and GC-MS for monitoring chemical agents on different types of surfaces (glass, painted metal, rubber, and cotton butyl rubber). These tests revealed high decontamination factors for BCWA even after only 10 min, accomplishing the requirements imposed by NATO standards. At the completion of the decontamination process, the formulations reached 100% efficacy for Bacillus anthracis after 10–15 min, for soman after 20–30 min, and for mustard gas in an interval comprised between 5 and 24 h depending on the type of surface analyzed.

15 August 2024 in Polymers
Verified
Journal Article
Open access
PDF file
FAFlorentina Alexe
Florentina Alexe
CSCiprian Sau
Ciprian Sau
OIOvidiu Iorga
Ovidiu Iorga
Gabriela ToaderGabriela Toader
Gabriela Toader
Aurel DiaconAurel Diacon
Aurel Diacon
ASArcadie Sobetkii
Arcadie Sobetkii
Shear thickening fluids (STFs) have garnered attention as potential enhancers of protective capabilities and for the optimization of Kevlar® armor design. To assess the possible shear thickening properties and potential application in ballistic protection, ten formulations were developed by employing polyethylene glycol (PEG) or polypropylene glycol (PPG), along with fumed silica or Aerosil HDK®. Rheological characterization facilitated the identification of formulations displaying shear thickening behavior. The potential integration of the selected shear thickening fluids (STFs) into Kevlar®-based composites was investigated by studying the impact resistance of Kevlar® soft armor structures. Also, high-velocity impact testing revealed that the distance between aramid layers plays a crucial role in the impact resistance effectiveness of Kevlar®–STF composite structures and that there is a very narrow domain between optimal and undesired scenarios in which STF could facilitate the penetration of Kevlar. The introduction of STF between the Kevlar sheets disrupted this packing and the energy absorption capacity of the material was not improved. Only one formulation (PEG400, Aerosil 27 wt.%) led to a less profound traumatic imprint and stopped the bullet when it was placed between layers no.1 and no.2 from a total of 11 layers of Kevlar XP. These experimental findings align with the modeling and simulation of Kevlar®–STF composites using Ansys simulation software (Ansys® AutoDyn 2022 R2).

29 July 2025 in Crystals
Verified
Journal Article
Open access
PDF file
CNCosmin Nicolescu
Cosmin Nicolescu
TTTudor Viorel Tiganescu
Tudor Viorel Tiganescu
AAAntoniac Aurora
Antoniac Aurora
OIOvidiu Iorga
Ovidiu Iorga
BGBrandusa Ghiban
Brandusa Ghiban
Antoniac IulianAntoniac Iulian
Antoniac Iulian
The aim of the current study is to investigate the mechanical properties and ballistic performance of HARDOX 450 steel for defense applications in different conditions: uncoated, alumina-coated, and LINE X polyurea-coated. Tensile tests and Vickers microhardness measurements were conducted, along with fracture surface analysis using stereomicroscopy, scanning electron microscopy, and computed tomography. Experimental results showed that uncoated HARDOX 450 steel exhibited the highest strength and hardness, with ductile fracture features. Polyurea-coated HARDOX 450 steel samples retained good mechanical properties and demonstrated effective ballistic protection, including the containment of fragments. In contrast, alumina-coated HARDOX 450 steel samples exhibited reduced strength and ballistic resistance, attributed to the microstructural changes in HARDOX 450 steel caused by the high-temperature deposition process of alumina. Numerical simulations performed with the 5.56 × 45 mm bullet used in the simulation, along with its ballistic impact interaction with the Hardox 450 target model, aligned well with experimental ballistic impact results for all the samples. Overall, LINE X polyurea coating on HARDOX 450 steel proved to be the more suitable coating for applications requiring a balance of mechanical strength and ballistic impact resistance.

27 June 2017 in International conference KNOWLEDGE-BASED ORGANIZATION
Verified
Journal Article
Open access
PDF file
OIOvidiu Iorga
Ovidiu Iorga
OOOctavian Orban
Octavian Orban
LMLiviu Matache
Liviu Matache
CECristiana Epure
Cristiana Epure
This paper presents the development, testing and evaluation of a new unguided rocket equipped with a thermobaric warhead. The aim of the research was to design the ammunition to be integrated with an existing multiple launch rocket system. This condition introduced limitations of dimensions, mass and mass distribution. The experimental work consisted also in optimisation of the thermobaric composition and configuration. The resulting ammunition was tested for determination of effective range and precision. The destructive effect was evaluated by live firing against non-armoured vehicles and masonry light structures.

1 June 2018 in International conference KNOWLEDGE-BASED ORGANIZATION
Verified
Journal Article
Open access
PDF file
OIOvidiu Iorga
Ovidiu Iorga
MMMihail Munteanu
Mihail Munteanu
TȚTudor-Viorel Țiganescu
Tudor-Viorel Țiganescu
The purpose of this paper is to present theoretical and experimental aspects regarding the design and testing of a thermobaric unguided fin-stabilized reactive projectile destined to be fired from a recoilless smoothbore gun, namely the anti-tank grenade launcher SPG-9 (AG-9). Some theoretical aspects regarding thermobaric explosive mechanism are presented and experimental determinations are made considering the relation between the explosive core and the overall calibre of the munition. The interior and exterior ballistics of the munitions are estimated by mathematical models and the results are validated through experimental firings with the prototype munition. The destructive effect of the munition is estimated by real firings against buildings and structures