Connecting distributed generation (DG) to weak distribution networks can often cause voltage rise problems. Traditionally, these voltage rise problems have been mitigated by passive methods such as reinforcing the network. This can, however, lead to high connection costs of DG. The connection costs can in many cases be lowered if active voltage control methods are used instead of the passive approach. In this paper, two coordinated voltage control algorithms suitable for usage in distribution networks including several distributed energy resources are proposed and studied. The first algorithm uses control rules to determine its control actions and the second algorithm utilizes optimization. The operation of the implemented algorithms is, at first, studied using time domain simulations. Thereafter, the network effects and costs of both algorithms are compared using statistical distribution network planning and also practical implementation issues are discussed.
In Finland, customer class load profiles are used extensively in distribution network calculation. State estimation systems, for example, use the load profiles to estimate the state of the network. Load profiles are also needed to predict future loads in distribution network planning. In general, customer class load profiles are obtained through sampling in load research projects. Currently, in Finland, customer classification is based on the uncertain customer information found in the customer information system. Customer information, such as customer type, heating solution, and tariff, is used to connect the customers with corresponding customer class load profiles. Now that the automatic meter-reading systems are becoming more common, customer classification and load profiling could be done according to actual consumption data. This paper proposes the use of the ISODATA algorithm for customer classification. The proposed customer classification and load profiling method also includes temperature dependency correction and outlier filtering. The method is demonstrated in this paper by studying a set of 660 hourly metered customers.
Anticipating load characteristics on low voltage circuits is an area of increased concern for Distribution Network Operators with uncertainty stemming primarily from the validity of domestic load profiles. Identifying customer behavior makeup on a LV feeder ascertains the thermal and voltage constraints imposed on the network infrastructure; modeling this highly dynamic behavior requires a means of accommodating noise incurred through variations in lifestyle and meteorological conditions. Increased penetration of distributed generation may further worsen this situation with the risk of reversed power flows on a network with no transformer automation. Smart Meter roll-out is opening up the previously obscured view of domestic electricity use by providing high resolution advance data; while in most cases this is provided historically, rather than real-time, it permits a level of detail that could not have previously been achieved. Generating a data driven profile of domestic energy use would add to the accuracy of the monitoring and configuration activities undertaken by DNOs at LV level and higher which would afford greater realism than static load profiles that are in existing use. In this paper, a linear Gaussian load profile is developed that allows stratification to a finer level of detail while preserving a deterministic representation.
29 January 2015 in IEEE Transactions on Power Delivery
Low-voltage direct-current (LVDC) distribution is a promising solution whose benefits are large power transfer capacity with low voltage, high cost savings potential, and improvements to reliability and voltage quality. Tests by the pilot implementation in the distribution system operator (DSO) Elenia Oy have given promising results. The power transfer capacity of the system has been calculated in this paper using voltage drop and maximum load of cable as boundaries. The branches of the medium-voltage network that can be replaced by LVDC distribution are determined based on the calculations and mass computation of the entire distribution area of Elenia Oy. Based on the electrotechnical and customer outage costs (COC) analyses made, it can be inferred that LVDC distribution has good utilization potential. Based on the power transfer capacity calculations, it is technically possible to replace branch lines up to 8 km long by LVDC distribution which means about 20% of the total medium-voltage network length in the distribution area of Elenia Oy. This means also huge potential in improving the overall reliability of electricity supply and in reducing outage costs of customers which are these days taken into account in the regulation of network business.