Bruce Stephen

Dr. Bruce Stephen

Department of Electronic and Electrical Engineering, University of Strathclyde, Glasgow G1 1RD, United Kingdom
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2015 in IEEE Transactions on Smart Grid
Verified
Journal Article
Open access
BSBruce Stephen
Bruce Stephen
XTXiaoqing Tang
Xiaoqing Tang
PHPoppy R. Harvey
Poppy R. Harvey
SGStuart Galloway
Stuart Galloway
KJKyle I. Jennett
Kyle I. Jennett
Aspirations of grid independence could be achieved by residential power systems connected only to small highly variable loads if overall demand on the network can be accurately anticipated. Absence of the diversity found on networks with larger load cohorts or consistent industrial customers makes such overall load profiles difficult to anticipate on even a short term basis. Here, existing forecasting techniques are employed alongside enhanced classification/clustering models in proposed methods for forecasting demand in a bottom up manner. A Markov chain based sampling technique derived from practice theory of human behavior is proposed as a means of providing a forecast with low computational effort and reduced historical data requirements. The modeling approach proposed does not require seasonal adjustments or environmental data. Forecast and actual demand for a cohort of residential loads over a five-month period are used to evaluate a number of models, as well as demonstrate a significant performance improvement if utilized in an ensemble forecast.

15 December 2011 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
SGSimon Gill
Simon Gill
BSBruce Stephen
Bruce Stephen
SGStuart Galloway
Stuart Galloway
Power curves constructed from wind speed and active power output measurements provide an established method of analyzing wind turbine performance. In this paper, it is proposed that operational data from wind turbines are used to estimate bivariate probability distribution functions representing the power curve of existing turbines so that deviations from expected behavior can be detected. Owing to the complex form of dependency between active power and wind speed, which no classical parameterized distribution can approximate, the application of empirical copulas is proposed; the statistical theory of copulas allows the distribution form of marginal distributions of wind speed and power to be expressed separately from information about the dependency between them. Copula analysis is discussed in terms of its likely usefulness in wind turbine condition monitoring, particularly in early recognition of incipient faults such as blade degradation, yaw, and pitch errors.

7 December 2015 in IEEE Transactions on Power Systems
Verified
Journal Article
Open access
XCXue Cao
Xue Cao
BSBruce Stephen
Bruce Stephen
IAIbrahim F. Abdulhadi
Ibrahim F. Abdulhadi
CBCampbell Booth
Campbell Booth
GBGraeme M. Burt
Graeme M. Burt
Future power systems could benefit considerably from having a continuous real-time estimate of system inertia. If realized, this could provide reference inputs to proactive control and protection systems which could enhance not only system stability but also operational economics through, for example, more informed ancillary reserve planning using knowledge of prevailing system conditions and stability margins. Performing these predictions in real time is a significant challenge owing to the complex stochastic and temporal relationships between available measurements. This paper proposes a statistical model capable of estimating system inertia in real time through observed steady-state and relatively small frequency variations; it is trained to learn the features that inter-relate steady-state averaged frequency variations and system inertia, using historical system data demonstrated over two consecutive years. The proposed algorithm is formulated as a Gaussian Mixture Model with temporal dependence encoded as Markov chains. Applied to the U.K. power system, it produces an optimized mean squared error within 0.1 s2 for 95% of the daily estimation if being calibrated on a half-hourly basis and maintains robustness through measurement interruptions of up to a period of two hours.

29 November 2016 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Open access
RTRory David Telford
Rory David Telford
SGStuart Galloway
Stuart Galloway
BSBruce Stephen
Bruce Stephen
IEIan Elders
Ian Elders
Increasing prevalence of dc sources and loads has resulted in dc distribution being reconsidered at a microgrid level. However, in comparison to ac systems, the lack of a natural zero crossing has traditionally meant that protecting dc systems is inherently more difficult-this protection issue is compounded when attempting to diagnose and isolate fault conditions. One such condition is the series arc fault, which poses significant protection issues as their presence negates the logic of overcurrent protection philosophies. This paper proposes the IntelArc system to accurately diagnose series arc faults in dc systems. IntelArc combines time-frequency and time-domain extracted features with hidden Markov models (HMMs) to discriminate between nominal transient behavior and arc fault behavior across a variety of operating conditions. Preliminary testing of the system is outlined with results showing that the system has the potential for accurate, generalized diagnosis of series arc faults in dc systems.

1 February 2019 in Renewable Energy
Verified
Journal Article
Open access
EGElena Gonzalez
Elena Gonzalez
BSBruce Stephen
Bruce Stephen
DIDavid Infield
David Infield
JMJulio J. Melero
Julio J. Melero

11 November 2013 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
BSBruce Stephen
Bruce Stephen
AMAntti J. Mutanen
Antti J. Mutanen
SGStuart Galloway
Stuart Galloway
Graeme BurtGraeme Burt
Graeme Burt
PJPertti Järventausta
Pertti Järventausta
Anticipating load characteristics on low voltage circuits is an area of increased concern for Distribution Network Operators with uncertainty stemming primarily from the validity of domestic load profiles. Identifying customer behavior makeup on a LV feeder ascertains the thermal and voltage constraints imposed on the network infrastructure; modeling this highly dynamic behavior requires a means of accommodating noise incurred through variations in lifestyle and meteorological conditions. Increased penetration of distributed generation may further worsen this situation with the risk of reversed power flows on a network with no transformer automation. Smart Meter roll-out is opening up the previously obscured view of domestic electricity use by providing high resolution advance data; while in most cases this is provided historically, rather than real-time, it permits a level of detail that could not have previously been achieved. Generating a data driven profile of domestic energy use would add to the accuracy of the monitoring and configuration activities undertaken by DNOs at LV level and higher which would afford greater realism than static load profiles that are in existing use. In this paper, a linear Gaussian load profile is developed that allows stratification to a finer level of detail while preserving a deterministic representation.