Eva Fellinger

Mrs. Eva Fellinger

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
EFEva Fellinger
Eva Fellinger
TBTom Brandt
Tom Brandt
JCJustin Creutzburg
Justin Creutzburg
TRTessa Rommerskirchen
Tessa Rommerskirchen
Annette SchmidtAnnette Schmidt
Annette Schmidt
Continuous Glucose Monitoring (CGM) not only can be used for glycemic control in chronic diseases (e.g., diabetes), but is increasingly being utilized by individuals and athletes to monitor fluctuations in training and everyday life. However, it is not clear how accurately CGM reflects plasma glucose concentration in a healthy population in the absence of chronic diseases. In an oral glucose tolerance test (OGTT) with forty-four healthy male subjects (25.5 ± 4.5 years), the interstitial fluid glucose (ISFG) concentration obtained by a CGM sensor was compared against finger-prick capillary plasma glucose (CPG) concentration at fasting baseline (T0) and 30 (T30), 60 (T60), 90 (T90), and 120 (T120) min post OGTT to investigate differences in measurement accuracy. The overall mean absolute relative difference (MARD) was 12.9% (95%-CI: 11.8–14.0%). Approximately 100% of the ISFG values were within zones A and B in the Consensus Error Grid, indicating clinical accuracy. A paired t-test revealed statistically significant differences between CPG and ISFG at all time points (T0: 97.3 mg/dL vs. 89.7 mg/dL, T30: 159.9 mg/dL vs. 144.3 mg/dL, T60: 134.8 mg/dL vs. 126.2 mg/dL, T90: 113.7 mg/dL vs. 99.3 mg/dL, and T120: 91.8 mg/dL vs. 82.6 mg/dL; p < 0.001) with medium to large effect sizes (d = 0.57–1.02) and with ISFG systematically under-reporting the reference system CPG. CGM sensors provide a convenient and reliable method for monitoring blood glucose in the everyday lives of healthy adults. Nonetheless, their use in clinical settings wherein implications are drawn from CGM readings should be handled carefully.

13 September 2025 in Neurobiology of Stress
Verified
Journal Article
Open access
EFEva Fellinger
Eva Fellinger
TBTom Brandt
Tom Brandt
ASAndrea Schittenhelm
Andrea Schittenhelm
EQEric Quarg
Eric Quarg
MPMatthias Pröll
Matthias Pröll
Annette SchmidtAnnette Schmidt
Annette Schmidt
The Trier Social Stress Test (TSST) is a widely used tool for inducing and measuring stress responses in a controlled environment. In this study, we aimed to explore the effectiveness of a virtual TSST (TSST-VR) in eliciting stress responses across multiple physiological and psychological markers. A sample of 24 participants underwent the TSST-VR, during which salivary cortisol, alpha-amylase (AA), blood glucose levels, heart rate (HR), root mean square of successive differences (RMSSD) as a measure of heart rate variability (HRV), and subjective stress ratings (NRS) were collected at multiple time points. In a baseline-to-peak analysis, significant increases were observed in HR (MDiff = 13.04, 95 %-CI [8.19-17.90], p < .001), RMSSD (MDiff = 17.75, 95 %-CI [3.28-32.22], p < .001), AA (p < .001, r = 1.07), and NRS (p < .001, r = 1.31) measures following the TSST-VR. While no significant changes in cortisol levels were found in the baseline-to-peak analysis across all participants, a secondary cluster analysis identified distinct cortisol responders (baseline-to-peak rise >1.5 mmol/l). Within this group, high cortisol responders (HCR) showed significantly higher cortisol (Wald χ2(7) = 118.03, p < .001), HR (Wald χ2(8) = 17.91, p = .022), and AA levels (Wald χ2(7) = 17.13, p = .017) compared to low cortisol responders (LCR). Area-under-the-curve analysis further confirmed a more robust cortisol stress response in HCR. These findings suggest that the TSST-VR can effectively induce measurable stress responses and may provide insights into individual differences in physiological and metabolic stress reactions. The study highlights the potential of virtual stress paradigms in stress research and underscores the advantages of a virtual setting in terms of standardization and economic considerations.

27 September 2026 in Small Science
Verified
Journal Article
Open access
PDF file
BSBajramshahe Shkodra
Bajramshahe Shkodra
KAKsenija Arslanova
Ksenija Arslanova
EFEva Fellinger
Eva Fellinger
TSTanja Stimpel‐Lindner
Tanja Stimpel‐Lindner
SKSebastian Klenk
Sebastian Klenk
GDGeorg Duesberg
Georg Duesberg
Monitoring of biomarkers in body fluids is highly sought after for medical diagnostics and tracking health conditions. Conventional analytical methods require centralized facilities and complex protocols, limiting applicability for real‐time or point‐of‐care use. In recent years, graphene‐based transducers have shown high potential for miniaturized biosensing, however they have so far been hardly tested in real‐case scenarios. In this work, electrolyte‐gated graphene field‐effect transistors (EG‐GFETs) are developed for the detection of the primary stress hormone cortisol in human saliva. The sensor consists of chemical vapor deposition (CVD)‐grown graphene functionalized with perylene bisimide (PBI) linkers for immobilizing anticortisol (17) Fab fragments. Cortisol is detected over a dynamic range from 100 fM to 1 μM, covering physiologically relevant concentration ranges. The measurements show high correlation with enzyme‐linked immunosorbent assay (ELISA) tests performed in parallel on the same samples. The immediate, label‐free sensing of biomarkers in human saliva represents a major advance in miniaturized biosensing and can potentially be extended to further analytes and integrated portable monitoring units.