Bajramshahe Shkodra

Ms. Bajramshahe Shkodra

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in Applied Physics Reviews
Verified
Journal Article
Open access
PDF file
BSBajramshahe Shkodra
Bajramshahe Shkodra
Mattia PetrelliMattia Petrelli
Mattia Petrelli
MAMartina Aurora Costa Angeli
Martina Aurora Costa Angeli
Denis GaroliDenis Garoli
Denis Garoli
NNNako Nakatsuka
Nako Nakatsuka
LPLuisa Petti
Luisa Petti
Nowadays, there is a high demand for sensitive and selective real-time analytical methods suitable for a wide range of applications, from personalized telemedicine, drug discovery, food safety, and quality control, to defense, security, as well as environmental monitoring. Biosensors are analytical devices able to detect bio-chemical analytes (e.g., neurotransmitters, cancer biomarkers, bio-molecules, and ions), through the combination of a bio-recognition element and a bio-transduction device. The use of customized bio-recognition elements such as enzymes, antibodies, aptamers, and ion-selective membranes facilitates achieving high selectivity. Among the different bio-transduction devices currently available, electrolyte-gated field-effect transistors, in which the dielectric is represented by an ionic liquid buffer solution containing the targeted analyte, are gaining increasing attention. Indeed, these bio-transduction devices are characterized by superior electronic properties and intrinsic signal amplification that allow the detection of a wide range of bio-molecules with high sensitivity (down to pM concentration). A promising semiconducting material for bio-transduction devices is represented by carbon nanotubes, due to their unique electrical properties, nanosize, bio-compatibility, and their simple low-cost processability. This work provides a comprehensive and critical review of electrolyte-gated carbon nanotube field-effect transistor-based biosensors. First, an introduction to these bio-sensing devices is given. Next, the device configurations and operating principles are presented, and the most used materials and processes are reviewed with a particular focus on carbon nanotubes as the active material. Subsequently, different functionalization strategies reported in the literature, based on enzymes, antibodies, aptamers, and ion-selective membranes, are analyzed critically. Finally, present issues and challenges faced in the area are investigated, the conclusions are drawn, and a perspective outlook over the field of bio-sensing technologies, in general, is provided.

1 December 2021 in ACS Omega
Verified
Journal Article
Open access
AIAKM SARWAR INAM
AKM SARWAR INAM
MAMartina A. Costa Angeli
Martina A. Costa Angeli
BSBajramshahe Shkodra
Bajramshahe Shkodra
ADAli Douaki
Ali Douaki
EAEnrico Avancini
Enrico Avancini
PLPaolo Lugli
Paolo Lugli
Nitrate (NO3–) contamination is becoming a major concern due to the negative effects of an excessive NO3– presence in water which can have detrimental effects on human health. Sensitive, real-time, low-cost, and portable measurement systems able to detect extremely low concentrations of NO3– in water are thus becoming extremely important. In this work, we present a novel method to realize a low-cost and easy to fabricate amperometric sensor capable of detecting small concentrations of NO3– in real water samples. The novel fabrication technique combines printing of a silver (Ag) working electrode with subsequent modification of the electrode with electrodeposited copper (Cu) nanoclusters. The process was tuned in order to reach optimized sensor response, with a high catalytic activity toward electroreduction of NO3– (sensitivity: 19.578 μA/mM), as well as a low limit of detection (LOD: 0.207 nM or 0.012 μg/L) and a good dynamic linear concentration range (0.05 to 5 mM or 31 to 310 mg/L). The sensors were tested against possible interference analytes (NO2–, Cl–, SO42–, HCO3–, CH3COO–, Fe2+, Fe3+, Mn2+, Na+, and Cu2+) yielding only negligible effects [maximum standard deviation (SD) was 3.9 μA]. The proposed sensors were also used to detect NO3– in real samples, including tap and river water, through the standard addition method, and the results were compared with the outcomes of high-performance liquid chromatography (HPLC). Temperature stability (maximum SD 3.09 μA), stability over time (maximum SD 3.69 μA), reproducibility (maximum SD 3.20 μA), and repeatability (maximum two-time useable) of this sensor were also investigated.

9 August 2024 in Nano Futures
Verified
Journal Article
Open access
VPVincenzo Pecunia
Vincenzo Pecunia
LPLuisa Petti
Luisa Petti
Joseph AndrewsJoseph Andrews
Joseph Andrews
RORiccardo Ollearo
Riccardo Ollearo
GGGerwin H Gelinck
Gerwin H Gelinck
WLWei Lin Leong
Wei Lin Leong
The dissemination of sensors is key to realizing a sustainable, ‘intelligent’ world, where everyday objects and environments are equipped with sensing capabilities to advance the sustainability and quality of our lives—e.g. via smart homes, smart cities, smart healthcare, smart logistics, Industry 4.0, and precision agriculture. The realization of the full potential of these applications critically depends on the availability of easy-to-make, low-cost sensor technologies. Sensors based on printable electronic materials offer the ideal platform: they can be fabricated through simple methods (e.g. printing and coating) and are compatible with high-throughput roll-to-roll processing. Moreover, printable electronic materials often allow the fabrication of sensors on flexible/stretchable/biodegradable substrates, thereby enabling the deployment of sensors in unconventional settings. Fulfilling the promise of printable electronic materials for sensing will require materials and device innovations to enhance their ability to transduce external stimuli—light, ionizing radiation, pressure, strain, force, temperature, gas, vapours, humidity, and other chemical and biological analytes. This Roadmap brings together the viewpoints of experts in various printable sensing materials—and devices thereof—to provide insights into the status and outlook of the field. Alongside recent materials and device innovations, the roadmap discusses the key outstanding challenges pertaining to each printable sensing technology. Finally, the Roadmap points to promising directions to overcome these challenges and thus enable ubiquitous sensing for a sustainable, ‘intelligent’ world.

10 April 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
BSBajramshahe Shkodra
Bajramshahe Shkodra
Biresaw Demelash AberaBiresaw Demelash Abera
Biresaw Demelash Abera
GCGiuseppe Cantarella
Giuseppe Cantarella
ADAli Douaki
Ali Douaki
EAEnrico Avancini
Enrico Avancini
PLPaolo Lugli
Paolo Lugli
Heterocyclic amine histamine is a well-known foodborne toxicant (mostly linked to “scombroid poisoning”) synthesized from the microbial decarboxylation of amino acid histidine. In this work, we report the fabrication of a flexible screen-printed immunosensor based on a silver electrode coated with single-walled carbon nanotubes (SWCNTs) for the detection of histamine directly in fish samples. Biosensors were realized by first spray depositing SWCNTs on the working electrodes and by subsequently treating them with oxygen plasma to reduce the unwanted effects related to their hydrophobicity. Next, anti-histamine antibodies were directly immobilized on the treated SWCNTs. Histamine was detected using the typical reaction of histamine and histamine-labeled with horseradish peroxidase (HRP) competing to bind with anti-histamine antibodies. The developed immunosensor shows a wide linear detection range from 0.005 to 50 ng/mL for histamine samples, with a coefficient of determination as high as 98.05%. Average recoveries in fish samples were observed from 96.00% to 104.7%. The biosensor also shows good selectivity (less than 3% relative response for cadaverine, putrescine, and tyramine), reproducibility, mechanical and time stability, being a promising analytical tool for the analysis of histamine, as well as of other food hazards.

2 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
AIAKM SARWAR INAM
AKM SARWAR INAM
MAMartina Aurora Costa Angeli
Martina Aurora Costa Angeli
ADAli Douaki
Ali Douaki
BSBajramshahe Shkodra
Bajramshahe Shkodra
PLPaolo Lugli
Paolo Lugli
LPLuisa Petti
Luisa Petti
In this work, we propose a novel disposable flexible and screen-printed electrochemical aptamer-based sensor (aptasensor) for the rapid detection of chlorpyrifos (CPF). To optimize the process, various characterization procedures were employed, including Fourier transform infrared spectroscopy (FT-IR), electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV). Initially, the aptasensor was optimized in terms of electrolyte pH, aptamer concentration, and incubation time for chlorpyrifos. Under optimal conditions, the aptasensor showed a wide linear range from 1 to 105 ng/mL with a calculated limit of detection as low as 0.097 ng/mL and sensitivity of 600.9 µA/ng. Additionally, the selectivity of the aptasensor was assessed by identifying any interference from other pesticides, which were found to be negligible (with a maximum standard deviation of 0.31 mA). Further, the stability of the sample was assessed over time, where the reported device showed high stability over a period of two weeks at 4 °C. As the last step, the ability of the aptasensor to detect chlorpyrifos in actual samples was evaluated by testing it on banana and grape extracts. As a result, the device demonstrated sufficient recovery rates, which indicate that it can find application in the food industry.

30 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Biresaw Demelash AberaBiresaw Demelash Abera
Biresaw Demelash Abera
Inmaculada Ortiz-GómezInmaculada Ortiz-Gómez
Inmaculada Ortiz-Gómez
BSBajramshahe Shkodra
Bajramshahe Shkodra
Francisco J RomeroFrancisco J Romero
Francisco J Romero
GCGiuseppe Cantarella
Giuseppe Cantarella
Almudena Rivadeneyra TorresAlmudena Rivadeneyra Torres
Almudena Rivadeneyra Torres
Tetracycline (TC) is a widely known antibiotic used worldwide to treat animals. Its residues in animal-origin foods cause adverse health effects to consumers. Low-cost and real-time measuring systems of TC in food samples are, therefore, extremely needed. In this work, a three-electrode sensitive and label-free sensor was developed to detect TC residues from milk and meat extract samples, using CO2 laser-induced graphene (LIG) electrodes modified with gold nanoparticles (AuNPs) and a molecularly imprinted polymer (MIP) used as a synthetic biorecognition element. LIG was patterned on a polyimide (PI) substrate, reaching a minimum sheet resistance (Rsh) of 17.27 ± 1.04 Ω/sq. The o-phenylenediamine (oPD) monomer and TC template were electropolymerized on the surface of the LIG working electrode to form the MIP. Surface morphology and electrochemical techniques were used to characterize the formation of LIG and to confirm each modification step. The sensitivity of the sensor was evaluated by differential pulse voltammetry (DPV), leading to a limit of detection (LOD) of 0.32 nM, 0.85 nM, and 0.80 nM in buffer, milk, and meat extract samples, respectively, with a working range of 5 nM to 500 nM and a linear response range between 10 nM to 300 nM. The sensor showed good LOD (0.32 nM), reproducibility, and stability, and it can be used as an alternative system to detect TC from animal-origin food products.