Bartlomiej Kaluzny

Prof. Bartlomiej Kaluzny

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 August 2009 in Optics Express
Verified
Journal Article
Closed access
PDF file
MGMichalina Gora
Michalina Gora
Karol KarnowskiKarol Karnowski
Karol Karnowski
MSMaciej Szkulmowski
Maciej Szkulmowski
BKBartlomiej Kaluzny
Bartlomiej Kaluzny
RHRobert Huber
Robert Huber
MWMaciej Wojtkowski
Maciej Wojtkowski
We present an application of in vivo anterior segment imaging of the human eye with an ultrahigh speed swept source OCT instrument. For this purpose, a dedicated OCT system was designed and constructed. This instrument enables axial zooming by automatic reconfiguration of spectral sweep range; an enhanced imaging range mode enables imaging of the entire anterior segment while a high axial resolution mode provides detailed morphological information of the chamber angle and the cornea. The speed of 200,000 lines/s enables high sampling density in three-dimensional imaging of the entire cornea in 250 ms promising future applications of OCT for optical corneal topography, pachymetry and elevation maps. The results of a preliminary quantitative corneal analysis based on OCT data free form motion artifacts are presented. Additionally, a volumetric and real time reconstruction of dynamic processes, like pupillary reaction to light stimulus or blink-induced contact lens movements are demonstrated.

11 July 2011 in Optics Express
Verified
Journal Article
Closed access
PDF file
DADavid Alonso-Caneiro
David Alonso-Caneiro
Karol KarnowskiKarol Karnowski
Karol Karnowski
BKBartlomiej Kaluzny
Bartlomiej Kaluzny
AKAndrzej Kowalczyk
Andrzej Kowalczyk
MWMaciej Wojtkowski
Maciej Wojtkowski
We present a novel method and instrument for in vivo imaging and measurement of the human corneal dynamics during an air puff. The instrument is based on high-speed swept source optical coherence tomography (ssOCT) combined with a custom adapted air puff chamber from a non-contact tonometer, which uses an air stream to deform the cornea in a non-invasive manner. During the short period of time that the deformation takes place, the ssOCT acquires multiple A-scans in time (M-scan) at the center of the air puff, allowing observation of the dynamics of the anterior and posterior corneal surfaces as well as the anterior lens surface. The dynamics of the measurement are driven by the biomechanical properties of the human eye as well as its intraocular pressure. Thus, the analysis of the M-scan may provide useful information about the biomechanical behavior of the anterior segment during the applanation caused by the air puff. An initial set of controlled clinical experiments are shown to comprehend the performance of the instrument and its potential applicability to further understand the eye biomechanics and intraocular pressure measurements. Limitations and possibilities of the new apparatus are discussed.

29 August 2011 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
Karol KarnowskiKarol Karnowski
Karol Karnowski
BKBartlomiej Kaluzny
Bartlomiej Kaluzny
MSMaciej Szkulmowski
Maciej Szkulmowski
MGMichalina Gora
Michalina Gora
MWMaciej Wojtkowski
Maciej Wojtkowski
We present the applicability of high-speed swept source (SS) optical coherence tomography (OCT) for quantitative evaluation of the corneal topography. A high-speed OCT device of 108,000 lines/s permits dense 3D imaging of the anterior segment within a time period of less than one fourth of second, minimizing the influence of motion artifacts on final images and topographic analysis. The swept laser performance was specially adapted to meet imaging depth requirements. For the first time to our knowledge the results of a quantitative corneal analysis based on SS OCT for clinical pathologies such as keratoconus, a cornea with superficial postinfectious scar, and a cornea 5 months after penetrating keratoplasty are presented. Additionally, a comparison with widely used commercial systems, a Placido-based topographer and a Scheimpflug imaging-based topographer, is demonstrated.

1 February 2016 in Medicine
Verified
Journal Article
Open access
BKBartlomiej Kaluzny
Bartlomiej Kaluzny
ICIwona Cieslinska
Iwona Cieslinska
SASamuel Arba-Mosquera
Samuel Arba-Mosquera
SVShwetabh Verma
Shwetabh Verma
Transepithelial photorefractive keratectomy (tPRK), where both the epithelium and stroma are removed in a single-step, is a relatively new procedure of laser refractive error correction. This study compares the 3-month results of myopia and compound myopic astigmatism correction by tPRK or conventional alcohol-assisted PRK (aaPRK).This prospective, nonrandomized, case-control study recruited 148 consecutive patients; 93 underwent tPRK (173 eyes) and 55 aaPRK (103 eyes). Refractive results, predictability, safety, and efficacy were evaluated during the 3-month follow-up. The main outcome measures were uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and mean refractive spherical equivalent (MRSE).Mean preoperative MRSE was -4.30 ± 1.72 D and -4.33 ± 1.96 D, respectively (P = 0.87). The 3-month follow-up rate was 82.1% in the tPRK group (n = 145) and 86.4% in aaPRK group (n = 90), P = 0.81. Postoperative UDVA was 20/20 or better in 97% and 94% of eyes, respectively (P = 0.45). In the tPRK and aaPRK groups, respectively, 13% and 21% of eyes lost 1 line of CDVA, and 30% and 31% gained 1 or 2 lines (P = 0.48). Mean postoperative MRSE was -0.14 ± 0.26 D in the tPRK group and -0.12 ± 0.20 D in the aaPRK group (P = 0.9). The correlation between attempted versus achieved MRSE was equally high in both groups.Single-step transepithelial PRK and conventional PRK provide very similar results 3 months postoperatively. These procedures are predictable, effective, and safe for correction of myopia and compound myopic astigmatism.

1 May 2012 in Optometry and Vision Science
Verified
Journal Article
Closed access
MWMaciej Wojtkowski
Maciej Wojtkowski
BKBartlomiej Kaluzny
Bartlomiej Kaluzny
Robert J. ZawadzkiRobert J. Zawadzki
Robert J. Zawadzki

1 September 2006 in Cornea
Verified
Journal Article
Closed access
BKBartlomiej Kaluzny
Bartlomiej Kaluzny
JKJakub J Kałużny
Jakub J Kałużny
ASAnna Msc Szkulmowska
Anna Msc Szkulmowska
IGIwona MSc Gorczyńska
Iwona MSc Gorczyńska
MSMaciej Szkulmowski
Maciej Szkulmowski
PTPiotr Targowski
Piotr Targowski
Purpose: Spectral optical coherence tomography (SOCT) is a new, noninvasive, noncontact, high-resolution technique that provides cross-sectional images of the objects that weakly absorb and scatter light. SOCT, because of very short acquisition time and high sensitivity, is capable of providing tomograms of substantially better quality than the conventional OCT. The aim of this paper is to show the application of the SOCT to cross-sectional imaging of the cornea and its pathologies. Methods: Eleven eyes with different corneal pathologies were examined with a slit lamp and the use of a prototype SOCT instrument constructed in the Institute of Physics, Nicolaus Copernicus University, Toruń, Poland. Results: Our SOCT system provides high-resolution (4 μm axial, 10 μm transversal) tomograms composed of 3000-5000 A-scans with an acquisition time of 120-200 ms. The quality of the images is adequate for detailed cross-sectional evaluation of various corneal pathologies. Objective assessment of the localization, size, shape, and light-scattering properties of the changed tissue is possible. Corneal and epithelial thickness and the depth and width of lesions can be estimated. Conclusion: SOCT technique allows acquiring clinically valuable cross-sectional optical biopsy of the cornea and its pathologies.