Stability calculation is the main objective during the analysis of domes. To investigate the effects of the initial defect, geometric nonlinearity, and material nonlinearity on the stability performance of different dome structures, 60 m numerical models were built and optimized by an iterative force-finding APDL program. Then, linear buckling analysis, geometric nonlinear stability analysis, geometric nonlinear stability analysis with initial defects, and dual nonlinear analysis with initial defects were discussed to compare the stability performance of ridge-beam cable domes (RCDs), suspen-domes, and conventional cable domes via finite element analysis. The results show that the buckling loads all follow the order of initial defect + dual nonlinear analysis < initial defect + geometric nonlinear analysis < geometric nonlinear analysis < linear buckling. The addition of ridge beams improves the overall stability and transforms the instability modes from local concave instability to overall torsional buckling. The ultimate load amplification coefficients of the RCD are close to those of the suspen-dome, while the vertical displacements of the RCD are more than those of the conventional cable dome, so the RCD has sufficient stiffness to reduce local displacement. Under 2–3 load combinations, internal ridge beams change from a tensile-bending state to a compressive-bending state, causing the entire instability of the RCD afterwards.
As a full tension structural system, the spoke-type single-layer cable net structure has a light graceful shape and superior mechanical properties. During construction, the structure will gradually be tensioned from the flexible unstressed state to the formed state with stiffness, and the structural configuration changes greatly, making construction difficult. This study focused on the spoke-type single-layer cable net structure of the Linyi Olympic Sports Center Stadium. The structural finite element model was established in ANSYS, and the construction scheme was selected and simulated using the nonlinear dynamic finite element method (NDFEM). Most of the existing structural automatic measuring systems are suitable for measuring points with gentle deformation. However, there is the lack of a stable and reliable automatic configuration monitoring system for the construction of single-layer cable net structures. Based on the Lecia TS16 robotic total station (RTS), the configuration automatic monitoring system (CAMS) was developed to obtain the coordinate data of key nodes on the ring cable and compression ring during the construction process. The original finite element model of clamps was refined to obtain the corresponding data in ANSYS. The results indicate that the selected construction scheme has a rational mechanical response according to the finite element simulation. The radial cable force when anchoring the traction cables is smaller than or equal to that in the formed state, which proves that the construction method of anchoring in batches is safe. The results of the ANSYS simulation is basically consistent with those obtained by CAMS, proving that the simulation method is credible. CAMS has good stability and measurement accuracy and can achieve the automatic monitoring of large structural deformation. The research findings provide valuable guidance for practical construction and other similar projects.
The reflector of a Chinese 500 m aperture spherical radio telescope is supported by a giant cable-net structure. In the actual operation process, active displacement observation is realized by connecting the actuators with the control cables to adjust the cable net, which requires high manufacturing and installation accuracy. In this study, an error sensitivity computing method based on a normal distribution is adopted to perform single-error computing and multi-error coupling computing and to investigate the effect of the length error of all the cables, tensioning force error of active surface cables, and installation error of external nodes on the cable force. The results show that the length error of the surface cables and the installation error of the external nodes are the main factors affecting the cable force, while the length error of the control cables is a secondary factor. The coupling effect of multiple errors is not the linear superposition of each error’s influence; therefore, all the error factors should be comprehensively considered for coupling computing to determine the control index. Through multi-error coupling computing, it is determined that the length error limits of the surface cables and control cables are ±1.5 mm and ±20 mm, respectively, the tensioning force error limit of the active surface cables is ±10%, and the installation error limit of the external nodes is ±50 mm.
To reveal the stable bearing capacity of a new semi-rigid dome structure, the tensile–beam cable dome (TBCD), a detailed numerical simulation and analysis of a 60 m model TBCD is conducted. Then, the effects of factors such as the prestress level, original imperfection size, original imperfection distribution, and addition of hoop tension rods on the stability of the TBCD model are investigated. The results show that the unstable loads of the TBCD are arranged from small to large in the following order: doubly nonlinearity with an original imperfection, geometry nonlinearity with an original imperfection, geometry nonlinearity without an original imperfection, and eigen buckling. In this case, the effects of geometry nonlinearity, material nonlinearity, and original imperfections must be comprehensively analyzed. The unstable mode of the TBCD depends on the loading form. Torsional buckling of the overall structure occurs under the symmetric load of ‘Full live + full dead’, while local out-of-plane buckling appears with the asymmetric load of ‘Half live + full dead’. With 2–3 times the loading integrations, the innermost tension beams change from stretch bending to pressurized bending, which causes the overall TBCD to become unstable. A small prestress level clearly decreases the stability of the TBCD, while a relatively large prestress level has little effect. When the original imperfection is greater than 1/400 of the span, the stability of the TBCD is problematic. Comprehensively considering the impact of multiple defects is needed when analyzing the buckling of the TBCD. Adding hoop tension beams between the top ends of rods can effectively improve the integrity and stability of the TBCD.