Xin Liu

Xin Liu

Auto-generated profile, based on publicly available information

Xin Liu

Nanjing Dong-Da Modern Prestressed Engineering Co., Ltd., Nanjing 210018, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2024 in Buildings
Verified
Journal Article
Open access
PDF file
ZDZenghui Di
Zenghui Di
FWFei Wang
Fei Wang
HYHualong Yu
Hualong Yu
XDXiang Dai
Xiang Dai
BLBin Luo
Bin Luo
XLXin Liu
Xin Liu
With the rapid development of the photovoltaic industry, flexible photovoltaic supports are increasingly widely used. Parameters such as the deflection, span, and cross-sectional dimensions of cables are important factors affecting their mechanical and economic performance. Therefore, in order to reduce steel consumption and cost and improve application value, it is crucial to design and optimize their initial morphology. In this paper, the mechanical behavior of a single-cable structure is introduced, and the simplified analytical formulations for internal force and displacement are deduced based on the geometric nonlinear characteristics and small strain assumption of the flexible photovoltaic supports. On this basis, the analytical expressions for the cable force and displacement of a convex prestressed double-layer cable truss flexible photovoltaic support structure under a uniform load are derived, and the correctness of the analytical formulations is verified by comparing the values with the finite element analysis results. In order to reduce the construction costs of the flexible photovoltaic support, a mathematical model for optimizing the initial structure’s morphology is established according to the analytical formulations. The initial morphology of the double-layer cable truss flexible photovoltaic support is optimized, and the optimization results of different deflection deformation limits and whether the lower load-bearing cable is allowed to relax are compared. The results indicate that the errors of the displacement formulation and cable force formulation, when compared with the finite element results, are less than 3% and 4%, respectively, which verifies the accuracy of the analytical formulations. By analyzing the cable force and displacement of the structure under static action, it is suggested that the deflection limit of the double-layer cable truss structure should be 1/100 of the single span. The lower load-bearing cables of the double-layer cable truss flexible photovoltaic support are highly susceptible to relaxation under wind suction loads, and, by comparing the optimization results, it is suggested that slack should be allowed in the lower load-bearing cables for a better economic effect. When choosing the most economical structure morphology, it is recommended that the total height of the mid-span struts should be 1/20~1/15 of the single span. The analytical formulation and the mathematical model for the optimization of the initial morphology proposed in this paper can provide certain theoretical references and bases for the design of practical engineering projects and play an important role in promoting its application and promotion.

16 August 2024 in Buildings
Verified
Journal Article
Open access
PDF file
FWFei Wang
Fei Wang
ZDZenghui Di
Zenghui Di
NZNingyuan Zhang
Ningyuan Zhang
YRYangjie Ruan
Yangjie Ruan
BLBin Luo
Bin Luo
XLXin Liu
Xin Liu
As a full tension structural system, the spoke-type single-layer cable net structure has a light graceful shape and superior mechanical properties. During construction, the structure will gradually be tensioned from the flexible unstressed state to the formed state with stiffness, and the structural configuration changes greatly, making construction difficult. This study focused on the spoke-type single-layer cable net structure of the Linyi Olympic Sports Center Stadium. The structural finite element model was established in ANSYS, and the construction scheme was selected and simulated using the nonlinear dynamic finite element method (NDFEM). Most of the existing structural automatic measuring systems are suitable for measuring points with gentle deformation. However, there is the lack of a stable and reliable automatic configuration monitoring system for the construction of single-layer cable net structures. Based on the Lecia TS16 robotic total station (RTS), the configuration automatic monitoring system (CAMS) was developed to obtain the coordinate data of key nodes on the ring cable and compression ring during the construction process. The original finite element model of clamps was refined to obtain the corresponding data in ANSYS. The results indicate that the selected construction scheme has a rational mechanical response according to the finite element simulation. The radial cable force when anchoring the traction cables is smaller than or equal to that in the formed state, which proves that the construction method of anchoring in batches is safe. The results of the ANSYS simulation is basically consistent with those obtained by CAMS, proving that the simulation method is credible. CAMS has good stability and measurement accuracy and can achieve the automatic monitoring of large structural deformation. The research findings provide valuable guidance for practical construction and other similar projects.

21 June 2024 in Buildings
Verified
Journal Article
Open access
PDF file
XCXiulong Chen
Xiulong Chen
BLBin Luo
Bin Luo
XLXin Liu
Xin Liu
This study proposes a new type of composite slab with a separate joint, which not only improves the assembly rate but also enables unsupported construction. A static loading test was conducted to investigate the bending behavior of the composite slab with a separate joint under a distributed load. The test results showed that the test composite slab had good integrity and crack resistance. The separate joint can effectively transmit internal forces and conform to the requirements of practical engineering. In addition, a finite element model was developed for the composite slab. The experimental load and numerical load corresponding to the longitudinal crack penetrating the bottom surface of the slab were 9.0 kN/m2 and 8.6 kN/m2, respectively, with an error of less than 5%. It was demonstrated that the finite element model can accurately predict the mechanical behavior of the composite slab.