Oleksiy V Voytsekhivskyy

Dr. Oleksiy V Voytsekhivskyy

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
DHDiogo Hipólito-Fernandes
Diogo Hipólito-Fernandes
MLMaria Elisa Luis
Maria Elisa Luis
PGPedro Gil
Pedro Gil
VMVitor Maduro
Vitor Maduro
JFJoão Feijão
João Feijão
NANuno Alves
Nuno Alves
Purpose: To compare the accuracy of a newly developed intraocular lens (IOL) power formula (VRF-G) with twelve existing formulas (Barret Universal II, EVO 2.0, Haigis, Hill-RBF 2.0, Hoffer Q, Holladay 1, Kane, Næeser 2, PEARL-DGS, SRK/T, T2 and VRF). Methods: Retrospective case series including 828 patients having uncomplicated cataract surgery with the implantation of a single IOL model (SN60WF). Using optimised constants, refraction prediction error of each formula was calculated for each eye. Subgroup analysis was performed based on the axial length (short ≤ 22.0mm; medium > 22.0mm to < 26.0mm; long ≥ 26.0mm). Main outcomes included mean prediction error (ME) mean (MAE) and median absolute error (MedAE), in diopters (D), and the percentage of eyes within ± 0.25D, ± 0.50D, ± 0.75D and ± 1.00D. Results: Formulas absolute errors were statistically different among them (p< 0.001), with Kane having the lowest MAE of all formulas, followed by EVO 2.0 and VRF-G, which had the lowest MedAE. The Kane formula had the highest percentage of eyes within ± 0.25D (47.0%) and ± 1.00D (97.7%) and the VRF-G formula had the highest percentage of eyes within ± 0.50D (79.5%). For all AL subgroups, Kane, EVO 2.0 and VRF-G formulas had the most accurate performances (lowest MAE). Conclusion: New generation formulas may help us in achieving better refractive results, lowering the variance in accuracy in extreme eyes – Kane, EVO 2.0 and VRF-G formulas are promising candidates to fulfil that goal.

1 January 2018 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
OVOleksiy V Voytsekhivskyy
Oleksiy V Voytsekhivskyy

26 July 2021 in Current Eye Research
Verified
Journal Article
Closed access
OVOleksiy V Voytsekhivskyy
Oleksiy V Voytsekhivskyy
KHKenneth Joseph Hoffer
Kenneth Joseph Hoffer
GSGiacomo Savini
Giacomo Savini
LTLarysa Tutchenko
Larysa Tutchenko
DHDiogo Hipólito-Fernandes
Diogo Hipólito-Fernandes
To analyze the accuracy of 18 intraocular lens (IOL) power calculation formulas in eyes with axial length (AL) ≤ 22 mm.We analyzed 241 eyes of 241 patients. Eighteen formulas were evaluated: Barret...

12 November 2024 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
WSWiktor Stopyra
Wiktor Stopyra
OVOleksiy V Voytsekhivskyy
Oleksiy V Voytsekhivskyy
Andrzej GrzybowskiAndrzej Grzybowski
Andrzej Grzybowski

1 January 2025 in Life
Verified
Journal Article
Open access
PDF file
WSWiktor Stopyra
Wiktor Stopyra
OVOleksiy V Voytsekhivskyy
Oleksiy V Voytsekhivskyy
Andrzej GrzybowskiAndrzej Grzybowski
Andrzej Grzybowski
Purpose: To compare the accuracy of seven artificial intelligence (AI)-based intraocular lens (IOL) power calculation formulas in medium-long Caucasian eyes regarding the root-mean-square absolute error (RMSAE), the median absolute error (MedAE) and the percentage of eyes with a prediction error (PE) within ±0.5 D. Methods: Data on Caucasian patients who underwent uneventful phacoemulsification between May 2018 and September 2023 in MW-Med Eye Center, Krakow, Poland and Kyiv Clinical Ophthalmology Hospital Eye Microsurgery Center, Kyiv, Ukraine were reviewed. Inclusion criteria, i.e., complete biometric and refractive data, were applied. Exclusion criteria were as follows: intraoperative or postoperative complications, previous eye surgery or corneal diseases, postoperative BCVA less than 0.8, and corneal astigmatism greater than 2.0 D. Prior to phacoemulsification, IOL power was computed using SRK/T, Holladay1, Haigis, Holladay 2, and Hoffer Q. The refraction was measured three months after cataract surgery. Post-surgery intraocular lens calculations for Hill-RBF 3.0, Kane, PEARL-DGS, Ladas Super Formula AI (LSF AI), Hoffer QST, Karmona, and Nallasamy were performed. RMSAE, MedAE, and the percentage of eyes with a PE within ±0.25 D, ±0.50 D, ±0.75 D, and ±1.00 were counted. Results: Two hundred fourteen eyes with axial lengths ranging from 24.50 mm to 25.97 mm were tested. The Hill-RBF 3.0 formula yielded the lowest RMSAE (0.368), just before Pearl-DGS (0.374) and Hoffer QST (0.378). The lowest MedAE was achieved by Hill-RBF 3.0 (0.200), the second-lowest by LSF AI (0.210), and the third-lowest by Kane (0.228). The highest percentage of eyes with a PE within ±0.50 D was obtained by Hill-RBF 3.0, LSF AI, and Pearl-DGS (86.45%, 85.51%, and 85.05%, respectively). Conclusions: The Hill-RBF 3.0 formula provided highly accurate outcomes in medium-long eyes. All studied AI-based formulas yielded good results in IOL power calculation.

11 May 2024 in Ophthalmology and Therapy
Verified
Journal Article
Open access
PDF file
WSWiktor Stopyra
Wiktor Stopyra
OVOleksiy V Voytsekhivskyy
Oleksiy V Voytsekhivskyy
Andrzej GrzybowskiAndrzej Grzybowski
Andrzej Grzybowski
Introduction The aim of this work is to compare 20 intraocular lens (IOL) power calculation formulas in medium-long eyes (24.50–25.99 mm) in terms of root mean square absolute error (RMSAE), median absolute error (MedAE), and percentage of eyes with prediction error (PE) within ± 0.50 D. Methods The data of patients who underwent uneventful phacoemulsification between January 2017 and September 2023 were reviewed. Pre-surgery IOL power was calculated using Holladay1, SRK/T, Hoffer Q, Holladay 2, and Haigis. Three months after phacoemulsification, refraction was measured. Post-surgery IOL power calculations were performed utilizing the following formulas: Barrett Universal II, Kane, K6, Olsen (OLCR), Olsen (standalone), PEARL-DGS, Ladas Super Formula AI (LSF AI), T2, EVO, VRF, Hoffer QST, Castrop, VRF-G, Karmona, and Naeser 2. RMSAE, MedAE, and percentage of eyes with PE within ± 0.25 D, ± 0.50 D, ± 0.75 D and ± 1.00 were calculated. Results One hundred twenty-four eyes with axial length ranges between 24.52 and 25.97 mm were studied. The SRK/T formula yielded the lowest RMSAE (0.206) just before Holladay 1 (0.260) and T2 (0.261). In terms of MedAE, the best outcome was obtained by SRK/T (0.12) followed by Barrett Universal II (0.15) and LSF AI (0.15). The highest percentage of eyes with prediction error within ± 0.50 D was achieved by SRK/T, T2, and Holladay 1 (97.58, 93.55, and 93.55%, respectively). Conclusions Third-generation formulas (SRK/T, Holladay 1) provided highly accurate outcomes in medium-long eyes and still can be wildly used to calculate IOL power.