Diogo Hipólito-Fernandes

Diogo Hipólito-Fernandes

Auto-generated profile, based on publicly available information

Diogo Hipólito-Fernandes

Department of Ophthalmology, Unidade Local de Saúde de São José, Lisbon, Portugal

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 November 2020 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
DHDiogo Hipólito-Fernandes
Diogo Hipólito-Fernandes
MLMaria Elisa Luis
Maria Elisa Luis
RSRita Serras-Pereira
Rita Serras-Pereira
PGPedro Gil
Pedro Gil
VMVitor Maduro
Vitor Maduro
NANuno Alves
Nuno Alves
Background/Aims To investigate the influence of anterior chamber depth (ACD) and lens thickness (LT) on 9 intraocular lens (IOL) power calculation formulas accuracy, in patients with normal axial lengths. Methods Retrospective case series, including patients having uncomplicated cataract surgery with insertion of a single IOL model, divided into three groups according to preoperative ACD. Each group was further subdivided into three subgroups, according to the LT. Using optimised constants, refraction prediction error was calculated for Barrett Universal II, Emmetropia Verifying Optical (EVO) V.2.0, Haigis, Hill-RBF V.2.0, Hoffer Q, Holladay 1, Kane, PEARL-DGS and SRK/T formulas. Mean prediction error, mean and median absolute error (MedAE) and the percentage of eyes within ±0.25D, ±0.50D and ±1.00D were also calculated. Results The study included 695 eyes from 695 patients. For ACD ≤3.0 mm and ≥3.5 mm, mean prediction error of SRK/T, Hoffer Q and Holladay 1 was significantly different from 0 (p<0.05). PEARL-DGS, Kane, EVO V.2.0 and Barrett Universal II were more accurate than the Hoffer Q in ACD ≤3.0 mm (p<0.05). Kane, PEARL-DGS, EVO V.2.0 and Barrett Universal II revealed the lowest variance of mean and MedAE by ACD and LT subgroup. Haigis and Hill-RBF V.2.0 were significantly influenced by LT, independently of the ACD, with a myopic shift with thin lenses and a hyperopic shift with thick lenses (p<0.05). Conclusion New generation formulas, particularly Kane, PEARL-DGS and EVO V.2.0, seem to be more reliable and stable even in eyes with extreme ACD-LT combinations.

1 December 2020 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
DHDiogo Hipólito-Fernandes
Diogo Hipólito-Fernandes
MLMaria Elisa Luis
Maria Elisa Luis
PGPedro Gil
Pedro Gil
VMVitor Maduro
Vitor Maduro
JFJoão Feijão
João Feijão
NANuno Alves
Nuno Alves
Purpose: To compare the accuracy of a newly developed intraocular lens (IOL) power formula (VRF-G) with twelve existing formulas (Barret Universal II, EVO 2.0, Haigis, Hill-RBF 2.0, Hoffer Q, Holladay 1, Kane, Næeser 2, PEARL-DGS, SRK/T, T2 and VRF). Methods: Retrospective case series including 828 patients having uncomplicated cataract surgery with the implantation of a single IOL model (SN60WF). Using optimised constants, refraction prediction error of each formula was calculated for each eye. Subgroup analysis was performed based on the axial length (short ≤ 22.0mm; medium > 22.0mm to < 26.0mm; long ≥ 26.0mm). Main outcomes included mean prediction error (ME) mean (MAE) and median absolute error (MedAE), in diopters (D), and the percentage of eyes within ± 0.25D, ± 0.50D, ± 0.75D and ± 1.00D. Results: Formulas absolute errors were statistically different among them (p< 0.001), with Kane having the lowest MAE of all formulas, followed by EVO 2.0 and VRF-G, which had the lowest MedAE. The Kane formula had the highest percentage of eyes within ± 0.25D (47.0%) and ± 1.00D (97.7%) and the VRF-G formula had the highest percentage of eyes within ± 0.50D (79.5%). For all AL subgroups, Kane, EVO 2.0 and VRF-G formulas had the most accurate performances (lowest MAE). Conclusion: New generation formulas may help us in achieving better refractive results, lowering the variance in accuracy in extreme eyes – Kane, EVO 2.0 and VRF-G formulas are promising candidates to fulfil that goal.

26 July 2021 in Current Eye Research
Verified
Journal Article
Closed access
OVOleksiy V Voytsekhivskyy
Oleksiy V Voytsekhivskyy
KHKenneth Joseph Hoffer
Kenneth Joseph Hoffer
GSGiacomo Savini
Giacomo Savini
LTLarysa Tutchenko
Larysa Tutchenko
DHDiogo Hipólito-Fernandes
Diogo Hipólito-Fernandes
To analyze the accuracy of 18 intraocular lens (IOL) power calculation formulas in eyes with axial length (AL) ≤ 22 mm.We analyzed 241 eyes of 241 patients. Eighteen formulas were evaluated: Barret...


18 August 2021 in International Journal of Retina and Vitreous
Verified
Journal Article
Open access
PDF file
DHDiogo Hipólito-Fernandes
Diogo Hipólito-Fernandes
MLMaria Elisa Luís
Maria Elisa Luís
DMDiogo Maleita
Diogo Maleita
PGPedro Gil
Pedro Gil
VMVitor Maduro
Vitor Maduro
NANuno Alves
Nuno Alves
Background: Our study aimed to assess and compare the accuracy of 8 intraocular lens (IOL) power calculation formulas (Barrett Universal II, EVO 2.0, Haigis, Hoffer Q, Holladay 1, Kane and PEARL-DGS) in patients submitted to combined phacovitrectomy for vitreomacular (VM) interface disorders. Methods: Retrospective chart review study including axial-length matched patients submitted to phacoemulsification alone (Group 1) and combined phacovitrectomy (Group 2). Using optimized constants in both groups, refraction prediction error of each formula was calculated for each eye. The optimised constants from Group 1 were also applied to patients of Group 2 – Group 3. Outcome measures included the mean prediction error (ME) and its standard deviation (SD), mean (MAE) and median (MedAE) absolute errors, in diopters (D), and the percentage of eyes within ± 0.25D, ± 0.50D and ± 1.00D. Results: A total of 220 eyes were included (Group 1: 100; Group 2: 120). In Group 1, the difference in formulas absolute error was significative (p = 0.005). The Kane Formula had the lowest MAE (0.306) and MedAE (0.264). In Group 2, Kane had the overall best performance, followed by PEARL-DGS, EVO 2.0 and Barrett Universal II. The ME of all formulas in both Groups 1 and 2 were 0.000 (p = 0.934; p = 0.971, respectively). In Group 3, a statistically significant myopic shift was observed for each formula (p < 0.001). Conclusion: Surgeons must be careful regarding IOL power selection in phacovitrectomy considering the systematic myopic shift evidenced—constant optimization may help eliminating such error. Moreover, newly introduced formulas and calculation methods may help us achieving increasingly better refractive outcomes both in cataract surgery alone and phacovitrectomy.

6 April 2021 in Current Eye Research
Verified
Journal Article
Closed access
DFDiogo Fernandes
Diogo Fernandes
MLMaria Luís
Maria Luís
JCJoana Cardigos
Joana Cardigos
CXCatarina Xavier
Catarina Xavier
MAMarta Alves
Marta Alves
JFJoana Ferreira
Joana Ferreira
Purpose/Aim: Our study aims to evaluate corneal subbasal nerve plexus morphology by in vivo corneal confocal microscopy (CCM) in Multiple Sclerosis (MS) patients, and to explore their potential ability to distinguish between MS patients and healthy subjects. Materials and Methods: Cross-sectional study, including sixty MS patients and twenty-two healthy subjects. Expanded Disability Status Scale (EDSS) was used to assess neurological disability. All participants underwent full ophthalmology evaluation, CCM and optical coherence tomography (OCT). Corneal nerve fibre density (CNFD), branch density (CNBD), fibre length (CNFL) and fibre tortuosity (CNFT) were analysed. Generalized additive regression models were used to analyse the data. Results: Compared to controls, MS patients had lower CNFD, CNBD and CNFL (p2.5 (-2.06 mm/mm2; 95%CI: -3.84 to -0.28; p=0.027 and -8.70 branches/mm2; 95%CI: -14.69 to -2.71; p=0.006, respectively). An optic neuritis (ON) history did not influence CCM parameters. Conclusions: Our results confirm CCM parameters’ potential to differentiate MS patients from healthy subjects, not being influenced by a previous ON history. A significant relationship between patient’s disability and corneal nerves morphology was also found.