Luyao Liu

Mr. Luyao Liu


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
LZLulu Zhang
Lulu Zhang
GMGuijun Miao
Guijun Miao
JZJing Zhang
Jing Zhang
LLLuyao Liu
Luyao Liu
SGShisong Gong
Shisong Gong
XCXing Chen
Xing Chen
Surface plasmon resonance (SPR) biosensors are an extremely sensitive optical technique used to detect the changes in refractive index occurring at the sensor interface. Fluorescence involves the emission of light by a substance that has absorbed light or other electromagnetic radiation, and the parameters of the absorbed and emitted radiation are used to identify the presence and the amount of specific molecules in a specimen. SPR biosensors and fluorescence analysis are both effective methods for real-time detection. The combination of these technologies would improve the quantitative detection sensitivity of fluorescence analysis and the specificity of SPR detection. We designed and developed an SPR and fluorescence synchronous detection system. The SPR module was based on two kinds of modulation methods, and the fluorescence module was capable of switching between four wavelengths. The fluorescence microspheres and A549 cells of different concentration were both detected by the SPR and fluorescence method synchronously in real time. The fluorescent signal and the optical signal of the SPR were shown to correlate. The correlation coefficient for fluorescent microspheres detection reached up to 0.9866. The system could be used in cell analysis and molecule diagnosis in the future.

3 August 2024 in Sensors
Verified
Journal Article
Open access
PDF file
NWNan Wang
Nan Wang
XDXiaobin Dong
Xiaobin Dong
YZYijie Zhou
Yijie Zhou
RZRui Zhu
Rui Zhu
LLLuyao Liu
Luyao Liu
XQXianbo Qiu
Xianbo Qiu
A low-cost, handheld centrifugal microfluidic system for multiplexed visual detection based on recombinase polymerase amplification (RPA) was developed. A concise centrifugal microfluidic chip featuring four reaction units was developed to run multiplexed RPA amplification in parallel. Additionally, a significantly shrunk-size and cost-effective handheld companion device was developed, incorporating heating, optical, rotation, and sensing modules, to perform multiplexed amplification and visual detection. After one-time sample loading, the metered sample was equally distributed into four separate reactors with high-speed centrifugation. Non-contact heating was adopted for isothermal amplification. A tiny DC motor on top of the chip was used to drive steel beads inside reactors for active mixing. Another small DC motor, which was controlled by an elaborate locking strategy based on magnetic sensing, was adopted for centrifugation and positioning. Visual fluorescence detection was optimized from different sides, including material, surface properties, excitation light, and optical filters. With fluorescence intensity-based visual detection, the detection results could be directly observed through the eyes or with a smartphone. As a proof of concept, the handheld device could detect multiple targets, e.g., different genes of African swine fever virus (ASFV) with the comparable LOD (limit of detection) of 75 copies/test compared to the tube-based RPA.