Bhagya R Navada

Dr. Bhagya R Navada


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2018 in Acta Mechanica et Automatica
Verified
Journal Article
Open access
PDF file
SVSanthosh Krishnan Venkata
Santhosh Krishnan Venkata
BNBhagya R Navada
Bhagya R Navada
In this paper, implementation of soft sensing technique for measurement of fluid flow rate is reported. The objective of the paper is to design an estimator to physically measure the flow in pipe by analysing the vibration on the walls of the pipe. Commonly used head type flow meter causes obstruction to the flow and measurement would depend on the placement of these sensors. In the proposed technique vibration sensor is bonded on the pipe of liquid flow. It is observed that vibration in the pipe varies with the control action of stem. Single axis accelerometer is used to acquire vibration signal from pipe, signal is passed from the sensor to the system for processing. Basic techniques like filtering, amplification, and Fourier transform are used to process the signal. The obtained transform is trained using neural network algorithm to estimate the fluid flow rate. Artificial neural network is designed using back propagation with artificial bee colony algorithm. Designed estimator after being incorporated in practical setup is subjected to test and the result obtained shows successful estimation of flow rate with the root mean square percentage error of 0.667.

29 October 2024 in Applied System Innovation
Verified
Journal Article
Open access
PDF file
BNBhagya R Navada
Bhagya R Navada
SVSravani V
Sravani V
SVSanthosh Krishnan Venkata
Santhosh Krishnan Venkata
The detection and mitigation of stiction are crucial for maintaining control system performance. This paper proposes the comparison of two preprocessing methods for detecting stiction in control valves via pattern recognition via an artificial neural network (ANN). This method utilizes process variables (PVs) and controller outputs (OPs) to accurately identify stiction within control loops. The ANN was comprehensively trained using data from a data-driven model after processing them. Validation and testing were conducted with real industrial data from the International Stiction Database (ISDB), ensuring a practical assessment framework. This study evaluated the impact of two preprocessing methods on fault detection accuracy, namely, the D-value and principal component analysis (PCA) methods, where the D-value method achieved a commendable overall accuracy of 76%, with 86% precision in stiction prediction and a 66% success rate in nonstiction scenarios. This signifies that feature reduction leads to a degraded stiction detection. The data-driven model was implemented in SIMULINK, and the ANN was trained in MATLAB with the Pattern Recognition Toolbox. These promising results highlight the method’s reliability in diagnosing stiction in industrial settings. Integrating this technique into existing control systems is expected to enhance maintenance protocols, reduce operational downtime, and improve efficiency. Future research should aim to expand this method’s applicability to a wider range of control systems and operational conditions, further solidifying its industrial value.

2 October 2019 in Machines
Verified
Journal Article
Open access
PDF file
BNBhagya R Navada
Bhagya R Navada
SVSanthosh Krishnan Venkata
Santhosh Krishnan Venkata
SRSwetha Rao
Swetha Rao
This article reports the design of a soft sensor for estimation of in-flow to the control valve in a flow process. The objective of the proposed work is to design and compare the performance of pole placement and Kalman filter-based observers. The observer is designed to estimate the in-flow from the measured out-flow. A mathematical model is derived for the considered physical plant using the system identification technique. An observer is designed using Pole Placement and Kalman Filter methods from the derived plant model. The obtained observer is implemented on a real-life setup for estimation of the in-flow rate. Results obtained from the designed observers are then analyzed to select the better observer. Comparison of performance based on results from Kalman Filter and Pole Placement method of observers shows that the former is more accurate, whereas the computation time is smaller in the latter. Results achieved from the designed soft sensor are verified using an electromagnetic flowmeter, and the results have a root-mean-square percentage error of 0.79%.

22 October 2024 in Computation
Verified
Journal Article
Open access
PDF file
ARAditya H R
Aditya H R
SVSravani V
Sravani V
AGAlankrit Gupta
Alankrit Gupta
SVSanthosh Krishnan Venkata
Santhosh Krishnan Venkata
BNBhagya R Navada
Bhagya R Navada
To address the challenge of precise flow rate measurement in microchannels, this research details the conceptualization and comprehensive evaluation of a thermal flowmeter which works on the principle of calorimetry for measuring small flow rates between 0.1 and 180 mL/h. The thermal flowmeter is composed of a silicone pipe, a heater, three platinum thermal sensors (T1, T2, T3), and water as the working fluid. The flowmeter is strategically placed to monitor the complex thermodynamics between upstream and downstream flows. The analysis revealed a notable decay in the slope of the temperature differences beyond a flow rate of 40 mL/h, indicating the exceptional sensitivity of the device at lower flow rates and making it an ideal choice for medical applications. Parametric analysis was also carried out to place the sensors at optimized locations for better sensitivity.


1 March 2025 in Journal of Robotics and Control (JRC)
Verified
Journal Article
Open access
PDF file
PMPreeti Mohanty
Preeti Mohanty
MRManu S R
Manu S R
SMShreyas M
Shreyas M
VUVishnumahanthi Uttam
Vishnumahanthi Uttam
BNBhagya R Navada
Bhagya R Navada
SVSanthosh Krishnan Venkata
Santhosh Krishnan Venkata
This paper explores advancements in surveillance systems, focusing on the integration of multisensory and AI technologies in urban and environmental monitoring. It highlights the fusion of data sources such as video feeds, LiDAR, and wireless networks for enhanced real-time surveillance in complex environments. Artificial intelligence (AI) plays a critical role in anomaly detection, object identification, and behavior analysis, improving response times in high-traffic and security-sensitive areas. However, these technologies raise privacy concerns, emphasizing the need for responsible data management and ethical frameworks. Also, there is probability of false positives which can lead to unnecessary action disturbing the normal mode of life. These technologies involve high financial requirements hence must be used judiciously. In current study human surveillance is carried out in indoor environments by two AI algorithms: YOLOV5 and R-CNN. The results of these algorithms can be fused with LiDAR data for better decision making. R-CNN produced better results than YOLOV5 but the fusion with sensor data led to accurate detection of humans in indoor environments. R-CNN showcased better results than YOLOV5. The future of surveillance should focus on balancing safety and personal rights while adapting policies to ensure privacy and accountability in an increasingly tech-driven world.