Swetha Rao

Ms. Swetha Rao


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 September 2019 in Electronics
Verified
Journal Article
Open access
PDF file
SVSanthosh Krishnan Venkata
Santhosh Krishnan Venkata
SRSwetha Rao
Swetha Rao
A control valve plays a very significant role in the stable and efficient working of a control loop for any process. In a fluid flow process, the probability of failure of a control valve may increase for many reasons pertaining to a flow process such as high pressures at the inlet, different properties of the liquid flowing through the pipe, mechanical issue related to a control valve, ageing, etc. A method to detect faults in the valve can lead to better stability of the control loop. In the proposed work, a technique is developed to determine the fault in a pneumatic control valve by analyzing the vibration data at the outlet of the valve. The fault diagnosis of the valve is carried out by analyzing the change in vibration of the pipe due to the change in flow pattern induced by the control valve. The faults being considered are inflow and insufficient supply pressure faults. Vibration data obtained is processed using a signal processing technique like amplification, Fourier transform, etc. The support vector machine (SVM) algorithm is used to classify the vibration data into two classes, one normal and the other faulty. The designed algorithm is trained to identify faults and subjected to test with a practical setup; test results show an accuracy of 97%.

6 January 2020 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
SVSanthosh Krishnan Venkata
Santhosh Krishnan Venkata
BJBlessy Joy
Blessy Joy
SRSwetha Rao
Swetha Rao
This paper presents the design of an instrument for measuring the liquid level. The objective of this proposed work is to measure the level of liquid accurately even with variations in liquid concentration. The designed instrument should also be able to compute the concentration of additives in the liquid. For this purpose, a multisensor model comprising a capacitive level sensor (CLS), ultrasonic level sensor (ULS), and capacitance pressure sensor is used to acquire information of the liquid. The data acquired from all these sensors are processed using Pau’s multisensor data fusion framework to compute the level of liquid along with the concentration of additives added to the solution. Pau’s framework consists of alignment, association function, analysis, and representation functions. The designed multisensor technique is tested with real-life data for varying liquid levels and additives. The results obtained show that the successful implementation of the proposed objective producing a root mean square of percentage error is 1.1% over the full scale is possible.

2 October 2019 in Machines
Verified
Journal Article
Open access
PDF file
BNBhagya R Navada
Bhagya R Navada
SVSanthosh Krishnan Venkata
Santhosh Krishnan Venkata
SRSwetha Rao
Swetha Rao
This article reports the design of a soft sensor for estimation of in-flow to the control valve in a flow process. The objective of the proposed work is to design and compare the performance of pole placement and Kalman filter-based observers. The observer is designed to estimate the in-flow from the measured out-flow. A mathematical model is derived for the considered physical plant using the system identification technique. An observer is designed using Pole Placement and Kalman Filter methods from the derived plant model. The obtained observer is implemented on a real-life setup for estimation of the in-flow rate. Results obtained from the designed observers are then analyzed to select the better observer. Comparison of performance based on results from Kalman Filter and Pole Placement method of observers shows that the former is more accurate, whereas the computation time is smaller in the latter. Results achieved from the designed soft sensor are verified using an electromagnetic flowmeter, and the results have a root-mean-square percentage error of 0.79%.

25 April 2021 in Transactions of the Institute of Measurement and Control
Verified
Journal Article
Closed access
PDF file
SKSanthosh Kv
Santhosh Kv
SRSwetha Rao
Swetha Rao
This paper aims at designing a differential pressure sensor. The objective of the work is to design and fabricate the electrodes of a capacitive pressure sensor, so as to measure absolute and differential pressure accurately with improved sensitivity. In place of conventional parallel plate diaphragm, S-type electrodes are proposed in the present work. The work comprises of study of the proposed design in terms of a mathematical model, input-output behavior along with detailed analysis of pressure distribution pattern. Output capacitance obtained for changes in pressure is converted to voltage with the suitable signal conditioning circuit and data acquisition system to acquire the signal on to a PC. A neural network model is designed to compensate the nonlinearities present in the sensor output. Input-output characteristics of the designed sensor shows an improved response as compared with existing pressure sensors.