Jun Yu

Prof. Jun Yu

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2024 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
ZLZhiyu Lin
Zhiyu Lin
LKLu Kang
Lu Kang
JZJinxiu Zhao
Jinxiu Zhao
YYYue Yin
Yue Yin
ZWZiheng Wang
Ziheng Wang
MSMengwei Si
Mengwei Si
In this work, we demonstrate indium–gallium–zinc oxide (IGZO) transistors fabricated on an 8-in wafer with high uniformity, steep subthreshold slope, and high reliability under positive bias temperature instability (PBTI) stress. The impact of channel compositions, gate dielectrics, and post-treatment conditions on PBTI degradation is systematically characterized and analyzed. The negative threshold voltage ( ${V}_{\text {TH}}{)}$ shift under positive stress is found to be determined by both hydrogen (H) and oxygen vacancy ( $\text{V}_{\text {O}}{)}$ , which is the dominating factor with the highest time exponent in PBTI of IGZO transistors. By reducing H concentration and suppressing $\text{V}_{\text {O}}$ generation by process engineering in gate-stack, semiconductor channel, and post-treatment condition, IGZO transistors with high PBTI reliability are demonstrated, achieving a low $\vert \Delta {V}_{\text {TH}}\vert $ of 11 mV at 95 °C, ${V}_{\text {stress}}$ of 3 V ( ${t}_{\text {ox}}$ = 7 nm, EOT = 3.2 nm by ${C}$ – ${V}$ measurements, and ${E}_{\text {OX}}$ of 3.7 MV/cm), and ${t}_{\text {stress}}$ of 2 ks.

26 February 2024 in iScience
Verified
Journal Article
Open access
DWDongping Wang
Dongping Wang
KJKai Jin
Kai Jin
JJJiajian Ji
Jiajian Ji
CHChenxuan Hu
Chenxuan Hu
MDMaohua Du
Maohua Du
Hanbin MaHanbin Ma
Hanbin Ma
Digital liquid sample handling is an enabling tool for cutting-edge life-sciences research. We present here an active-matrix thin-film transistor (TFT) based digital microfluidics system, referred to as Field Programmable Droplet Array (FPDA). The system contains 256 × 256 pixels in an active area of 10.65 cm2, which can manipulate thousands of addressable liquid droplets simultaneously. By leveraging a novel TFT device and circuits design solution, we manage to programmatically manipulate droplets at single-pixel level. The minimum achievable droplet volume is around 0.5 nL, which is two orders of magnitude smaller than the smallest droplet ever reported on active-matrix digital microfluidics. The movement of droplets can be either pre-programmed or controlled in real-time. The FPDA system shows great potential of the ubiquitous thin-film electronics technology in digital liquid handling. These efforts will make it possible to create a true programmable lab-on-a-chip device to enable great advances in life science research.

21 November 2025 in Nature Reviews Electrical Engineering
Verified
Journal Article
Closed access
PDF file
DWDongping Wang
Dongping Wang
SJShengzhe Jiang
Shengzhe Jiang
Hanbin MaHanbin Ma
Hanbin Ma
JYJun Yu
Jun Yu
ANArokia Nathan
Arokia Nathan

7 July 2023 in IEEE Journal of the Electron Devices Society
Verified
Journal Article
Open access
DWDongping Wang
Dongping Wang
SWShiqiang Wu
Shiqiang Wu
QHQi Huang
Qi Huang
CCChunyu Chang
Chunyu Chang
LXLongqian Xu
Longqian Xu
Hanbin MaHanbin Ma
Hanbin Ma
Emerging microfluidic tools are bringing new approaches to biological experiments on the scale of microdroplets and single cells. In this study, we designed an active-matrix digital microfluidics chip and investigated a driving signal strategy. The driving factors of ‘holding time’ and ‘delay time’ in the activematrix drive timing and the stability of droplet manipulation were optimized. Then, the drive signal was optimized to finally achieve the stable control of two different single high-throughput droplets. In this process, we also investigated how to maintain the stability of droplet driving while reducing the electrode degradation, extending the electrode and TFT circuit life and increasing the duration of the AM-DMF chip. The above work provides experience in the stable manipulation of single cells and the application of high-throughput droplet driving while allowing for cost savings.

7 July 2023 in IEEE Journal of the Electron Devices Society
Verified
Journal Article
Open access
YWYingbo Wei
Yingbo Wei
DWDongping Wang
Dongping Wang
SJShengzhe Jiang
Shengzhe Jiang
Hanbin MaHanbin Ma
Hanbin Ma
JYJun Yu
Jun Yu
In this paper, we proposed a high-voltage serial-in-parallel-out (SIPO) shift register based on amorphous silicon thin-film transistors (a-Si TFTs). We provided a detailed introduction of the bootstrap inverter, the key component of the proposed shift register, and presented the simulation and analysis of one-stage and five-stage SIPO shift registers, respectively. Then we fabricated the five-stage SIPO shift registers employing a-Si TFTs. Both the simulation results and experimental results show that the proposed SIPO shift register is capable of transmitting a 50 V high voltage pulse signal with a clock frequency of 20 kHz and is expected to be an important building block for the applications of digital microfluidics.

29 April 2024 in IEEE Electron Device Letters
Verified
Journal Article
Closed access
SJShengzhe Jiang
Shengzhe Jiang
DWDongping Wang
Dongping Wang
YWYingbo Wei
Yingbo Wei
CLChang Li
Chang Li
Hanbin MaHanbin Ma
Hanbin Ma
ANArokia Nathan
Arokia Nathan
This paper presents a droplet position sensing circuit designed for thin film transistor active-matrix digital microfluidics. The presented pixel design facilitates simultaneous implementation of droplet driving and position sensing functions. An 8x8 array was fabricated with standard thin film transistors compatible to mainstream display backplane technology. Measured results indicate a difference in output voltage of approximately 4 V between deionized water and air, demonstrating ample precision for accurate droplet position sensing. The driving and readout capability of the array has also been experimentally verified. The approach presented here is suitable for integration of TFT active-matrix digital microfluidics, offering a solution to enhance the efficiency and precision of droplet manipulation.