Debashish Das

Dr. Debashish Das

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 November 2023 in Energy and Buildings
Verified
Journal Article
Closed access
SKSamiran Khorat
Samiran Khorat
DDDebashish Das
Debashish Das
RKRupali Khatun
Rupali Khatun
SASk Mohammad Aziz
Sk Mohammad Aziz
Prashant AnandPrashant Anand
Prashant Anand
DNDev Niyogi
Dev Niyogi

15 April 2023 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
AKAnsar Khan
Ansar Khan
SKSamiran Khorat
Samiran Khorat
VDVan Q. Doan
Van Q. Doan
RKRupali Khatun
Rupali Khatun
DDDebashish Das
Debashish Das
DNDev Niyogi
Dev Niyogi
Different heat mitigation technologies have been developed to improve the thermal environment in cities. However, the regional impacts of such technologies, especially in the context of a tropical city, remain unclear. The deployment of heat mitigation technologies at city‐scale can change the radiation balance, advective flow, and energy balance between urban areas and the overlying atmosphere. We used the mesoscale Weather Research and Forecasting model coupled with a physically based single‐layer urban canopy model to assess the impacts of five different heat mitigation technologies on surface energy balance, standard surface meteorological fields, and planetary boundary layer (PBL) dynamics for premonsoon typical hot summer days over a tropical coastal city in the month of April in 2018, 2019, and 2020. Results indicate that the regional impacts of cool materials (CMs), super‐cool broadband radiative coolers, green roofs (GRs), vegetation fraction change, and a combination of CMs and GRs (i.e., “Cool city (CC)”) on the lower atmosphere are different at diurnal scale. Results showed that super‐cool materials have the maximum potential of ambient temperature reduction of 1.6°C during peak hour (14:00 LT) compared to other technologies in the study. During the daytime hours, the PBL height was considerably lower than the reference scenario with no implementation of strategies by 700 m for super‐cool materials and 500 m for both CMs and CC cases; however, the green roofing system underwent nominal changes over the urban area. During the nighttime hours, the PBL height increased by CMs and the CC strategies compared to the reference scenario, but minimal changes were evident for super‐cool materials. The changes of temperature on the vertical profile of the heat mitigation implemented city reveal a stable PBL over the urban domain and a reduction of the vertical mixing associated with a pollution dome. This would lead to crossover phenomena above the PBL due to the decrease in vertical wind speed. Therefore, assessing the coupled regional impact of urban heat mitigation over the lower atmosphere at city‐scale is urgent for sustainable urban planning.

21 February 2025 in Arabian Journal of Geosciences
Verified
Journal Article
Closed access
PDF file
SDSwarnava Dey
Swarnava Dey
JNJayita Guha Niyogi
Jayita Guha Niyogi
DDDebashish Das
Debashish Das

22 May 2023 in Remote Sensing
Verified
Journal Article
Open access
PDF file
TCTrisha Chakraborty
Trisha Chakraborty
DDDebashish Das
Debashish Das
Rafiq HamdiRafiq Hamdi
Rafiq Hamdi
AKAnsar Khan
Ansar Khan
DNDev Niyogi
Dev Niyogi
The unique geographical diversity and rapid urbanization across the Indian subcontinent give rise to large-scale spatiotemporal variations in urban heating and air emissions. The complex relationship between geophysical parameters and anthropogenic activity is vital in understanding the urban environment. This study analyses the characteristics of heating events using aerosol optical depth (AOD) level variability, across 43 urban agglomerations (UAs) with populations of a million or more, along with 13 industrial districts (IDs), and 14 biosphere reserves (BRs) in the Indian sub-continent. Pre-monsoon average surface heating was highest in the urban areas of the western (42 °C), central (41.9 °C), and southern parts (40 °C) of the Indian subcontinent. High concentration of AOD in the eastern part of the Indo-Gangetic Plain including the megacity: Kolkata (decadal average 0.708) was noted relative to other UAs over time. The statistically significant negative correlation (−0.51) between land surface temperature (LST) and AOD in urban areas during pre-monsoon time illustrates how aerosol loading impacts the surface radiation and has a net effect of reducing surface temperatures. Notable interannual variability was noted with, the pre-monsoon LST dropping in 2020 across most of the selected urban regions (approx. 89% urban clusters) while it was high in 2019 (for approx. 92% urban clusters) in the pre-monsoon season. The results indicate complex variability and correlations between LST and urban aerosol at large scales across the Indian subcontinent. These large-scale observations suggest a need for more in-depth analysis at city scales to understand the interplay and combined variability between physical and anthropogenic atmospheric parameters in mesoscale and microscale climates.


1 January 2023
Verified
Book Chapter
Closed access
PDF file
SSSohini Sen
Sohini Sen
DDDebashish Das
Debashish Das
PCPankaj Chakroborty
Pankaj Chakroborty
RGRaja Ghosh
Raja Ghosh