Takahiro Yamane

Mr. Takahiro Yamane

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2017 in Nature
Verified
Journal Article
Open access
PDF file
FAFusamichi Akita
Fusamichi Akita
MSMichihiro Sugahara
Michihiro Sugahara
MKMinoru Kubo
Minoru Kubo
YNYoshiki Nakajima
Yoshiki Nakajima
TNTakanori Nakane
Takanori Nakane
JSJian-Ren Shen
Jian-Ren Shen
Photosystem II (PSII) is a huge membrane-protein complex consisting of 20 different subunits with a total molecular mass of 350 kDa for a monomer. It catalyses light-driven water oxidation at its catalytic centre, the oxygen-evolving complex (OEC)1,2,3. The structure of PSII has been analysed at 1.9 Å resolution by synchrotron radiation X-rays, which revealed that the OEC is a Mn4CaO5 cluster organized in an asymmetric, ‘distorted-chair’ form4. This structure was further analysed with femtosecond X-ray free electron lasers (XFEL), providing the ‘radiation damage-free’5 structure. The mechanism of O=O bond formation, however, remains obscure owing to the lack of intermediate-state structures. Here we describe the structural changes in PSII induced by two-flash illumination at room temperature at a resolution of 2.35 Å using time-resolved serial femtosecond crystallography with an XFEL provided by the SPring-8 ångström compact free-electron laser. An isomorphous difference Fourier map between the two-flash and dark-adapted states revealed two areas of apparent changes: around the QB/non-haem iron and the Mn4CaO5 cluster. The changes around the QB/non-haem iron region reflected the electron and proton transfers induced by the two-flash illumination. In the region around the OEC, a water molecule located 3.5 Å from the Mn4CaO5 cluster disappeared from the map upon two-flash illumination. This reduced the distance between another water molecule and the oxygen atom O4, suggesting that proton transfer also occurred. Importantly, the two-flash-minus-dark isomorphous difference Fourier map showed an apparent positive peak around O5, a unique μ4-oxo-bridge located in the quasi-centre of Mn1 and Mn4 (refs 4,5). This suggests the insertion of a new oxygen atom (O6) close to O5, providing an O=O distance of 1.5 Å between these two oxygen atoms. This provides a mechanism for the O=O bond formation consistent with that proposed previously6,7.

18 October 2019 in Science
Verified
Journal Article
Closed access
PDF file
MSMichihiro Suga
Michihiro Suga
FAFusamichi Akita
Fusamichi Akita
KYKeitaro Yamashita
Keitaro Yamashita
YNYoshiki Nakajima
Yoshiki Nakajima
GUGo Ueno
Go Ueno
JSJian-Ren Shen
Jian-Ren Shen
Inspecting S states in photosynthesis: Oxygenic photosynthesis uses a Mn 4 CaO 5 cluster in the oxygen-evolving complex to extract electrons from water and produce dioxygen. Visualizing each of the chemical states in this process, S 0 to S 4 , and assigning chemical identities and mechanisms on the basis of structures has been a challenge addressed recently by work at x-ray free-electron lasers. Suga et al. used serial crystallography at cryogenic temperatures to trap and determine the structures of several stable states during photosystem II water oxidation (see the Perspective by Britt and Marchiori). Changes around the water cluster already happen in the S 2 state and set the stage for water insertion that occurs during transition to the S 3 state. A short 1.9-angstrom distance between the two oxygen atoms in the S 3 state is consistent with theoretical studies supporting an oxyl/oxo mechanism for oxygen-oxygen coupling. Science , this issue p. 334 ; see also p. 305

7 April 2021 in IUCrJ
Verified
Journal Article
Open access
PDF file
HLHongjie Li
Hongjie Li
YNYoshiki Nakajima
Yoshiki Nakajima
TNTakashi Nomura
Takashi Nomura
MSMichihiro Sugahara
Michihiro Sugahara
SYShinichiro Yonekura
Shinichiro Yonekura
JSJian-Ren Shen
Jian-Ren Shen
Photosystem II (PSII) catalyzes light-induced water oxidation through an S i -state cycle, leading to the generation of di-oxygen, protons and electrons. Pump–probe time-resolved serial femtosecond crystallography (TR-SFX) has been used to capture structural dynamics of light-sensitive proteins. In this approach, it is crucial to avoid light contamination in the samples when analyzing a particular reaction intermediate. Here, a method for determining a condition that avoids light contamination of the PSII microcrystals while minimizing sample consumption in TR-SFX is described. By swapping the pump and probe pulses with a very short delay between them, the structural changes that occur during the S1-to-S2 transition were examined and a boundary of the excitation region was accurately determined. With the sample flow rate and concomitant illumination conditions determined, the S2-state structure of PSII could be analyzed at room temperature, revealing the structural changes that occur during the S1-to-S2 transition at ambient temperature. Though the structure of the manganese cluster was similar to previous studies, the behaviors of the water molecules in the two channels (O1 and O4 channels) were found to be different. By comparing with the previous studies performed at low temperature or with a different delay time, the possible channels for water inlet and structural changes important for the water-splitting reaction were revealed.

17 June 2025 in Sensors
Verified
Journal Article
Open access
PDF file
TYTakahiro Yamane
Takahiro Yamane
MKMoeka Kimura
Moeka Kimura
MMMizuki MORITA
Mizuki MORITA
Human activity recognition using wearable accelerometer data can be a useful digital biomarker for severity assessment and the diagnosis of diseases, where the relationship between onset and patient activity is crucial. For long-term monitoring in clinical settings, the volume of data collected over time should be minimized to reduce power consumption, computational load, and communication volume. This study aimed to determine the lowest sampling frequency that maintains recognition accuracy for each activity. Thirty healthy participants wore nine-axis accelerometer sensors at five body locations and performed nine activities. Machine-learning-based activity recognition was conducted using data sampled at 100, 50, 25, 20, 10, and 1 Hz. Data from the non-dominant wrist and chest, which have previously shown high recognition accuracy, were used. Reducing the sampling frequency to 10 Hz did not significantly affect the recognition accuracy for either location. However, lowering the frequency to 1 Hz decreases the accuracy of many activities, particularly brushing teeth. Using data with a 10 Hz sampling frequency can maintain recognition accuracy while decreasing data volume, enabling long-term patient monitoring and device miniaturization for clinical applications.

6 March 2024 in Physical Activity and Health
Verified
Journal Article
Open access
TYTakahiro Yamane
Takahiro Yamane
MKMoeka Kimura
Moeka Kimura
MMMizuki MORITA
Mizuki MORITA

11 April 2025 in Sleep and Breathing
Verified
Journal Article
Open access
PDF file
TYTakahiro Yamane
Takahiro Yamane
MFMasanori Fujii
Masanori Fujii
MMMizuki MORITA
Mizuki MORITA
Purpose: To establish a simple and noninvasive screening test for sleep apnea (SA) that imposes less burden on potential patients. The specific objective of this study was to verify the effectiveness of past and future single-lead electrocardiogram (ECG) data from SA occurrence sites in improving the estimation accuracy of SA and sleep apnea syndrome (SAS) using machine learning. Methods: The Apnea-ECG dataset comprising 70 ECG recordings was used to construct various machine-learning models. The time window size was adjusted based on the accuracy of SA detection, and the performance of SA detection and SAS diagnosis (apnea‒hypopnea index ≥ 5 was considered SAS) was compared. Results: Using ECG data from a few minutes before and after the occurrence of SAs improved the estimation accuracy of SA and SAS in all machine learning models. The optimal range of the time window and achieved accuracy for SAS varied by model; however, the sensitivity ranged from 95.7 to 100%, and the specificity ranged from 91.7 to 100%. Conclusions: ECG data from a few minutes before and after SA occurrence were effective in SA detection and SAS diagnosis, confirming that SA is a continuous phenomenon and that SA affects heart function over a few minutes before and after SA occurrence. Screening tests for SAS, using data obtained from single-lead ECGs with appropriate past and future time windows, should be performed with clinical-level accuracy.