Mizuki MORITA

Dr. Mizuki MORITA

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 November 2021 in Cell Genomics
Verified
Journal Article
Open access
JLJonathan Lawson
Jonathan Lawson
MCMoran N. Cabili
Moran N. Cabili
GKGiselle Kerry
Giselle Kerry
TBTiffany Boughtwood
Tiffany Boughtwood
ATAdrian Thorogood
Adrian Thorogood
MCMélanie Courtot
Mélanie Courtot
Human biomedical datasets that are critical for research and clinical studies to benefit human health also often contain sensitive or potentially identifying information of individual participants. Thus, care must be taken when they are processed and made available to comply with ethical and regulatory frameworks and informed consent data conditions. To enable and streamline data access for these biomedical datasets, the Global Alliance for Genomics and Health (GA4GH) Data Use and Researcher Identities (DURI) work stream developed and approved the Data Use Ontology (DUO) standard. DUO is a hierarchical vocabulary of human and machine-readable data use terms that consistently and unambiguously represents a dataset’s allowable data uses. DUO has been implemented by major international stakeholders such as the Broad and Sanger Institutes and is currently used in annotation of over 200,000 datasets worldwide. Using DUO in data management and access facilitates researchers’ discovery and access of relevant datasets. DUO annotations increase the FAIRness of datasets and support data linkages using common data use profiles when integrating the data for secondary analyses. DUO is implemented in the Web Ontology Language (OWL) and, to increase community awareness and engagement, hosted in an open, centralized GitHub repository. DUO, together with the GA4GH Passport standard, offers a new, efficient, and streamlined data authorization and access framework that has enabled increased sharing of biomedical datasets worldwide.

20 February 2019 in Journal of Medical Internet Research
Verified
Journal Article
Open access
SWShoko Wakamiya
Shoko Wakamiya
MMMizuki MORITA
Mizuki MORITA
YKYoshinobu Kano
Yoshinobu Kano
TOTomoko Ohkuma
Tomoko Ohkuma
EAEiji Aramaki
Eiji Aramaki
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: The amount of medical and clinical-related information on the Web is increasing. Among the various types of information on the Web, social media-based data obtained directly from people are particularly valuable and garnering much attention. To encourage medical natural language processing research exploiting social media data, the NTCIR-13 MedWeb (Medical Natural Language Processing for Web Document) provides pseudo-Twitter messages in a cross-language and multi-label corpus, covering three languages (Japanese, English, and Chinese), and annotated with eight symptom labels (e.g., cold, fever, flu, and so on). Then, participants classify each tweet into one of two categories: those containing a patient’s symptom, and those that do not. Objective: We aim to present the results of groups participated in the Japanese subtask, the English subtask, and the Chinese subtask along with discussions, in order to clarify the issues that need to be resolved in the field of medical natural language processing. Methods: The performance of participant systems is assessed using the exact match accuracy, F-measure based on precision and recall, and Hamming loss. Results: In all, eight groups (19 systems) participated in the Japanese subtask, four groups (12 systems) participated in the English subtask, and two groups (six systems) participated in the Chinese subtask. The best system achieved .880 in exact match accuracy, .920 in F-measure, and .019 in Hamming loss. Conclusions: This paper presented and discussed the performance of systems participated in the NTCIR-13 MedWeb task. Because the MedWeb task settings can be formalized as the factualization of text, the achievement of this task could be applied directly to practical clinical applications.

17 June 2025 in Sensors
Verified
Journal Article
Open access
PDF file
TYTakahiro Yamane
Takahiro Yamane
MKMoeka Kimura
Moeka Kimura
MMMizuki MORITA
Mizuki MORITA
Human activity recognition using wearable accelerometer data can be a useful digital biomarker for severity assessment and the diagnosis of diseases, where the relationship between onset and patient activity is crucial. For long-term monitoring in clinical settings, the volume of data collected over time should be minimized to reduce power consumption, computational load, and communication volume. This study aimed to determine the lowest sampling frequency that maintains recognition accuracy for each activity. Thirty healthy participants wore nine-axis accelerometer sensors at five body locations and performed nine activities. Machine-learning-based activity recognition was conducted using data sampled at 100, 50, 25, 20, 10, and 1 Hz. Data from the non-dominant wrist and chest, which have previously shown high recognition accuracy, were used. Reducing the sampling frequency to 10 Hz did not significantly affect the recognition accuracy for either location. However, lowering the frequency to 1 Hz decreases the accuracy of many activities, particularly brushing teeth. Using data with a 10 Hz sampling frequency can maintain recognition accuracy while decreasing data volume, enabling long-term patient monitoring and device miniaturization for clinical applications.

21 September 2020 in Journal of Biomedical Semantics
Verified
Journal Article
Open access
PDF file
KKKohei Kajiyama
Kohei Kajiyama
HHHiromasa Horiguchi
Hiromasa Horiguchi
TOTakashi Okumura
Takashi Okumura
MMMizuki MORITA
Mizuki MORITA
YKYoshinobu Kano
Yoshinobu Kano
Background: Recently, more electronic data sources are becoming available in the healthcare domain. Electronic health records (EHRs), with their vast amounts of potentially available data, can greatly improve healthcare. Although EHR de-identification is necessary to protect personal information, automatic de-identification of Japanese language EHRs has not been studied sufficiently. This study was conducted to raise de-identification performance for Japanese EHRs through classic machine learning, deep learning, and rule-based methods, depending on the dataset. Results: Using three datasets, we implemented de-identification systems for Japanese EHRs and compared the de-identification performances found for rule-based, Conditional Random Fields (CRF), and Long-Short Term Memory (LSTM)-based methods. Gold standard tags for de-identification are annotated manually for age, hospital, person, sex, and time. We used different combinations of our datasets to train and evaluate our three methods. Our best F1-scores were 84.23, 68.19, and 81.67 points, respectively, for evaluations of the MedNLP dataset, a dummy EHR dataset that was virtually written by a medical doctor, and a Pathology Report dataset. Our LSTM-based method was the best performing, except for the MedNLP dataset. The rule-based method was best for the MedNLP dataset. The LSTM-based method achieved a good score of 83.07 points for this MedNLP dataset, which differs by 1.16 points from the best score obtained using the rule-based method. Results suggest that LSTM adapted well to different characteristics of our datasets. Our LSTM-based method performed better than our CRF-based method, yielding a 7.41 point F1-score, when applied to our Pathology Report dataset. This report is the first of study applying this LSTM-based method to any de-identification task of a Japanese EHR. Conclusions: Our LSTM-based machine learning method was able to extract named entities to be de-identified with better performance, in general, than that of our rule-based methods. However, machine learning methods are inadequate for processing expressions with low occurrence. Our future work will specifically examine the combination of LSTM and rule-based methods to achieve better performance. Our currently achieved level of performance is sufficiently higher than that of publicly available Japanese de-identification tools. Therefore, our system will be applied to actual de-identification tasks in hospitals.

6 March 2024 in Physical Activity and Health
Verified
Journal Article
Open access
TYTakahiro Yamane
Takahiro Yamane
MKMoeka Kimura
Moeka Kimura
MMMizuki MORITA
Mizuki MORITA

11 April 2025 in Sleep and Breathing
Verified
Journal Article
Open access
PDF file
TYTakahiro Yamane
Takahiro Yamane
MFMasanori Fujii
Masanori Fujii
MMMizuki MORITA
Mizuki MORITA
Purpose: To establish a simple and noninvasive screening test for sleep apnea (SA) that imposes less burden on potential patients. The specific objective of this study was to verify the effectiveness of past and future single-lead electrocardiogram (ECG) data from SA occurrence sites in improving the estimation accuracy of SA and sleep apnea syndrome (SAS) using machine learning. Methods: The Apnea-ECG dataset comprising 70 ECG recordings was used to construct various machine-learning models. The time window size was adjusted based on the accuracy of SA detection, and the performance of SA detection and SAS diagnosis (apnea‒hypopnea index ≥ 5 was considered SAS) was compared. Results: Using ECG data from a few minutes before and after the occurrence of SAs improved the estimation accuracy of SA and SAS in all machine learning models. The optimal range of the time window and achieved accuracy for SAS varied by model; however, the sensitivity ranged from 95.7 to 100%, and the specificity ranged from 91.7 to 100%. Conclusions: ECG data from a few minutes before and after SA occurrence were effective in SA detection and SAS diagnosis, confirming that SA is a continuous phenomenon and that SA affects heart function over a few minutes before and after SA occurrence. Screening tests for SAS, using data obtained from single-lead ECGs with appropriate past and future time windows, should be performed with clinical-level accuracy.