Electric vehicle (EV) charging presents both a challenge and an opportunity for modern power systems, particularly in workplace environments with grid constraints and dynamic energy pricing. This study presents a real-life implementation and experimental validation of a hierarchical distributed control system for smart EV charging. The proposed architecture combines upper-level receding horizon optimization with lower-level priority-based dispatch, enabling cost-efficient energy allocation and fair distribution among EVs. The system was deployed at the Risø campus of the Technical University of Denmark (DTU) and tested over two days under realistic operational conditions, including heterogeneous EV behavior and limited grid capacity. The control system demonstrated autonomous operation, responsiveness to price signals, and effective coordination between control layers. High energy delivery rates were achieved, nearly 100% on the first test day and close to 90% on the second, despite operating under a constrained energy budget. The study also documents practical challenges encountered during deployment, such as charger communication faults and EV-side issues, and proposes adaptation strategies. These results confirm the feasibility of distributed smart charging in real-world conditions and provide actionable insights for future implementations.
The demand for electric vehicle supply equipment (EVSE) is increasing because of the rapid shift toward electric transport. Introducing EVSE on a large scale into the power grid can increase power demand volatility, negatively affecting frequency stability. A viable solution to this challenge is the development of smart charging technologies capable of performing frequency regulation. This paper presents an experimental proof of concept for a new frequency regulation method for EVSE utilizing a distributed control architecture. The architecture dynamically adjusts the contribution of electric vehicles (EVs) to frequency regulation response based on the charging urgency assigned by the EV users. The method is demonstrated with two Renault ZOEs responding to frequency fluctuation with a combined power range of 6 kW in the frequency range of 50.1 to 49.9 Hz. The results confirm consistent power sharing and effective frequency regulation, with the system controlling the engagement of the EVs in frequency regulation based on priority. The delay and accuracy analyses reveal a fast and accurate response, with the cross-correlation indicating an 8.48 s delay and an average undershoot of 0.17 kW. In the conclusions, the paper discusses prospective improvements and outlines future research directions for integrating EVs as service providers.