Purpose CustusX is an image-guided therapy (IGT) research platform dedicated to intraoperative navigation and ultrasound imaging. In this paper, we present CustusX as a robust, accurate, and extensible platform with full access to data and algorithms and show examples of application in technological and clinical IGT research. Methods CustusX has been developed continuously for more than 15 years based on requirements from clinical and technological researchers within the framework of a well-defined software quality process. The platform was designed as a layered architecture with plugins based on the CTK/OSGi framework, a superbuild that manages dependencies and features supporting the IGT workflow. We describe the use of the system in several different clinical settings and characterize major aspects of the system such as accuracy, frame rate, and latency. Results The validation experiments show a navigation system accuracy of \(<\)1.1 mm, a frame rate of 20 fps, and latency of 285 ms for a typical setup. The current platform is extensible, user-friendly and has a streamlined architecture and quality process. CustusX has successfully been used for IGT research in neurosurgery, laparoscopic surgery, vascular surgery, and bronchoscopy. Conclusions CustusX is now a mature research platform for intraoperative navigation and ultrasound imaging and is ready for use by the IGT research community. CustusX is open-source and freely available at http://www.custusx.org.
1 July 2014 in Journal of Bronchology & Interventional Pulmonology
Navigated bronchoscopy uses virtual 3-dimensional lung model visualizations created from preoperative computed tomography images often in synchronization with the video bronchoscope to guide a tool to peripheral lesions. Navigated bronchoscopy has developed fast since the introduction of virtual bronchoscopy with integrated electromagnetic sensors in the late 1990s. The purposes of the review are to give an overview and update of the technological components of navigated bronchoscopy, an assessment of its clinical usefulness, and a brief assessment of the commercial platforms for navigated bronchoscopy. We performed a literature search with relevant keywords to navigation and bronchoscopy and iterated on the reference lists of relevant papers, with emphasis on the last 5 years. The paper presents an overview of the components necessary for performing navigated bronchoscopy, assessment of the diagnostic accuracy of different approaches, and an analysis of the commercial systems. We were able to identify 4 commercial platforms and 9 research and development groups with considerable activity in the field. Finally, on the basis of our findings and our own experience, we provide a discussion on navigated bronchoscopy with focus on the next steps of development. The literature review showed that the peripheral diagnostic accuracy has improved using navigated bronchoscopy compared with traditional bronchoscopy. We believe that there is room for improvement in the diagnostic success rate by further refinement of methods, approaches, and tools used in navigated bronchoscopy.
Background: The accuracy of navigated bronchoscopy relies on a best possible correlation between the preoperative computed tomography images used for planning and the actual tumor position during bronchoscopy. Change in lung structure during the procedure may reduce success rate. The size of the lung changes during breathing, which may be predicted and at least partly compensated by a navigation system. We have studied the effect of the bronchoscopy itself, to see if and how the procedure causes further distortions, which might be harder to predict and compensate. Methods: Using newly developed lung tracking sensors, we have measured the movement of individual lung segments during a bronchoscopy session in pigs. The bronchoscope was moved stepwise forward, ending in a wedge position, where it is often positioned when collecting peripheral biopsy specimens during conventional bronchoscopy. Results: The influence of the bronchoscope on lung segment movement was minimal while positioned in the trachea, main bronchus, or lobe bronchus. However, in the wedge position, it displaced the lung targets and reduced the natural respiratory motion. Conclusions: A bronchoscope placed in a wedge position displaces lung targets and affects their respiratory behavior. As an image navigation system guides the operator towards a position dictated by the preoperative computed tomography, the displacement found in this study may cause the operator to miss the target. This may be part of the explanation for the limited success rates reported in the literature for navigated bronchoscopy.
Electromagnetic guided bronchoscopy is a new field of research, essential for the development of advanced investigation of the airways and lung tissue. Consecutive problem-based solutions and refinements are urgent requisites to achieve improvements. For that purpose, our intention is to build a complete research platform for electromagnetic guided bronchoscopy. The experimental interventional electromagnetic field tracking system in conjunction with a C-arm cone beam CT unit is presented in this paper. The animal model and the navigation platform performed well and the aims were achieved; the 3D localization of foreign bodies and their navigated and tracked removal, assessment of tracking accuracy that showed a high level of precision, and assessment of image quality. The platform may prove to be a suitable platform for further research and development and a full-fledged electromagnetic guided bronchoscopy navigation system. The inclusion of the C-arm cone beam CT unit in the experimental setup adds a number of new possibilities for diagnostic procedures and accuracy measurements. Among other future challenges that need to be solved are the interaction between the C-arm and the electromagnetic navigation field, as we demonstrate in this feasibility study.