Yousef Alhorr

Dr. Yousef Alhorr


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 August 2024 in Buildings
Verified
Journal Article
Open access
PDF file
Amit Kant KaushikAmit Kant Kaushik
Amit Kant Kaushik
RIRubina Islam Islam
Rubina Islam Islam
Salma ElBahySalma ElBahy
Salma ElBahy
MAMohammed Arif
Mohammed Arif
Hord ArsalanHord Arsalan
Hord Arsalan
MRMuhammad Qasim Rana
Muhammad Qasim Rana
Over the past decade, there has been a dramatic increase in the use of various technologies in the Architecture, Engineering, and Construction sector. Artificial intelligence has played a significant role throughout the different phases of the design and construction process. A growing body of literature recognizes the importance of artificial neural network applications in numerous areas of the construction industry and the built environment, presenting a need to explore the main research themes, attributes, benefits, and challenges. A three-step extensive research method was utilized by conducting a bibliometric search of English language articles and conducting quantitative and qualitative analyses. The bibliometric analysis aimed to identify the current research directions and gaps forming future research areas. The scientometric analysis of keywords revealed diverse areas within the construction industry linked to ANNs. The qualitative analysis of the selected literature revealed that energy management in buildings and construction cost predictions were the leading research topics in the study area. These findings recommend directions for further research in the field, for example, broadening the application ranges of ANNs in the current Construction 4.0 technologies, such as robotics, 3D printing, digital twins, and VR applications.

18 October 2022 in Microorganisms
Verified
Journal Article
Open access
PDF file
HAhana abdelrahman
hana abdelrahman
LALubna I Abu-Rub
Lubna I Abu-Rub
HMHassan Al Mana
Hassan Al Mana
YAYousef Alhorr
Yousef Alhorr
ATAsmaa Al Thani
Asmaa Al Thani
NENahla Eltai
Nahla Eltai
Airborne bacteria pose a potential risk to human health upon inhalation in the indoor environments of health care facilities. Airborne bacteria may originate from various sources, including patients, workers, and daily visitors. Hence, this study investigates the quantity, size, and identification of airborne bacteria indoors and outdoors of four Primary Health Care Centers (PHCC) in Doha, Qatar. Air samples were collected from the lobby, triage room, and outside environment of the centers, including, Qatar University (QU-HC), Al-Rayyan (AR-HC), Umm-Ghuwailina (UG-HC), and Old Airport (OA-HC) between August 2020 and March 2021, throughout both the hot and the cold seasons. Samples were collected using an Anderson six-stage cascade impactor. The mean of the total colony-forming units was calculated per cubic meter of air (CFU/m3). QU-HC had the lowest mean of total bacterial count compared with other centers in the indoor and outdoor areas with 100.4 and 99.6 CFU/m3, respectively. In contrast, AR-HC had the highest level, with 459 CFU/m3 indoors, while OA-HC recorded the highest bacterial concentration of the outdoor areas with a total mean 377 CFU/m3. In addition, 16S rRNA sequencing was performed for genera identification. Staphylococcus, Acinetobacter, Bacillus, and Pseudomonas were the four most frequently identified bacterial genera in this study. The abundance of airborne bacteria in the four health centers was higher in the cold season. About 46% of the total airborne bacterial count for three PHCC centers exceeded 300 CFU/m3, making them uncompliant with the World Health Organization’s (WHO) recommendation for indoor settings. Consequently, an IAQ standards should be shaped to establish a baseline for measuring air pollution in Qatar. Additionally, it is crucial to understand seasonal fluctuations better so that hospitals can avoid rising and spreading infection peaks.

5 June 2015 in Buildings
Verified
Journal Article
Open access
PDF file
YAYousef Alhorr
Yousef Alhorr
EEEsam Elsarrag
Esam Elsarrag
It is well known that the Gulf Cooperation Council (GCC) of countries resides at or close to the top of the global table of CO2 emissions per capita and its economy relies heavily on its fossil fuels. This provides a context for green building programs that initially aim to create an understanding of emission pathways within the GCC and hence develop approaches to their reduction in the built environment. A set of criteria will allow specific analysis to be undertaken linked to the spatial dimensions of the sector under study. In this paper, approaches to modelling energy consumption and CO2 emissions are presented. As investment in the built environment continues, natural resources dwindle and the cost of energy increases, delivering low-energy buildings will become mandatory. In this study, a hybrid modelling approach (bottom-top & top-bottom) is presented. Energy benchmarks are developed for different buildings’ uses and compared with international standards. The main goals are to establish design benchmarks and develop a modelling tool that contains specific information for all buildings types (existing and new), as well as planned and projected growths within the various city districts, then integrate this database within a geospatial information system that will allow us to answer a range of “what-if”-type questions about various intervention strategies, emissions savings, and acceptability of pre-defined course of actions in the city sector under consideration. The spatial carbon intensity may be adjusted over a certain period, (e.g., through local generation (microgeneration)) or due to an increasing proportion of lower carbon-energy in the generation mix and this can be related to the sector and city overall consumption.

21 November 2019 in Processes
Verified
Journal Article
Open access
PDF file
YAYousef Alhorr
Yousef Alhorr
Bourhan TashtoushBourhan Tashtoush
Bourhan Tashtoush
NCNELSON Chilengwe
NELSON Chilengwe
MMMohamed Yusuff Musthafa
Mohamed Yusuff Musthafa
Evaporative cooling can be integrated into fresh-air-handling units, to reduce cooling demand. This study considers a hybrid fresh-air-handling unit which incorporates a vapor-compression cooling cycle and indirect evaporative cooling to condition an ambient primary airstream to a desired supply air state. The cooling effects of using various modes (vapor compression only; direct expansion with mist; direct expansion with water shower; and direct expansion with mist and water shower) are compared when the fresh-air-handling unit operates in harsh (hot and humid) climatic conditions experienced in Qatar. Experimental analysis is based on actual ambient conditions measured from August 2018 to July 2019. It is found that the best-performing wet mode of operation saves more than 60% of the energy required by a conventional direct expansion cooling system operating under the same ambient conditions. In hot, dry conditions, the coefficient of performance of the fresh-air-handling unit when using the indirect evaporative mode of operation is double the coefficient of performance when operating with direct expansion mode only.

22 January 2019 in Buildings
Verified
Journal Article
Open access
PDF file
AHAmer Hakki
Amer Hakki
Lu YangLu Yang
Lu Yang
FWFazhou Wang
Fazhou Wang
AEAmmar Elhoweris
Ammar Elhoweris
YAYousef Alhorr
Yousef Alhorr
DMDonald Macphee
Donald Macphee
Engineering of effective photocatalytically active structures is of great importance as it introduces a solution for some existing air pollution problems. This can be practically achieved through the bonding of particulate photocatalysts to the surface of construction materials, such as aggregates, with a suitable stable binding agent. However, the accessibility of the photocatalytically active materials to both the air pollutants and sunlight is an essential issue which must be carefully considered when engineering such structures. Herein, different amounts of commercial TiO2 were supported on the surface of quartz sand, as an example of aggregates, with a layer of silica gel acting as a binder between the photocatalyst and the support. The thus prepared photocatalytically active aggregates were then supported on the surface of mortars to measure their performance for NOx removal. The obtained materials were characterized by electron microscopy (SEM and TEM), Fourier Transform Infrared Spectroscopy (FTIR), X-ray Diffraction (XRD), and UV-vis Absorption Spectroscopy. Very good coverage of the support’s surface with the photocatalyst was successfully achieved as the electron microscopic images showed. FTIR spectroscopy confirmed the chemical bonding, i.e., interfacial Ti–O–Si bonds, between the photocatalyst and the silica layer. The photocatalytic activities of the obtained composites were tested for photocatalytic removal of nitrogen oxides, according to the ISO standard method (ISO 22197-1). The obtained aggregate-exposed mortars have shown up to ca. four times higher photocatalytic performance towards NO removal compared to the sample in which the photocatalyst is mixed with cement, however, the nitrate selectivity can be affected by Ti–O–Si bonding.

3 October 2018
Verified
Book Chapter
Open access
PDF file
EEEsam Elsarrag
Esam Elsarrag
YAYousef Alhorr
Yousef Alhorr
In hot-humid climates, cooling greenhouses and barns are needed to protect crops from extremely high temperature and to ensure high-yielding dairy cows. In Qatar, outside air temperature exceeds 46°C during summer, and the wet-bulb temperature can exceed 30°C which makes greenhouses and barns unworkable during this season. This study provides theoretical and experimental data for cooling greenhouses and barns using highly efficient and low-carbon technology (QGreen). QGreen uses groundwater (geothermal) for indirect-direct evaporative cooling coupled with desiccant dehumidification. The desiccant used is seawater bittern which is a by-product of the desalination process. A desiccant indirect-direct evaporative cooling panel system is designed and analyzed. The results show that the use of groundwater will enhance the efficiency and reduce the wet-bulb temperature dramatically. As a result, the efficiency of the overall cooling system is enhanced by more than 50% compared to the direct evaporative cooling efficiency that was recorded.