Hui Liu

Hui Liu


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2019 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
DLDeqing Luo
Deqing Luo
HRHong-Yue Ren
Hong-Yue Ren
WZWenjiao Zhang
Wenjiao Zhang
HXHang Xian
Hang Xian
KLKejian Lian
Kejian Lian
HLHui Liu
Hui Liu
Recently, many studies have shown the role of hypoxia-inducible factor-1α (HIF-1α) expression in the outcome of bone tumor. However, the results remain inconclusive. It is necessary to carry out a meta-analysis of all the current available data to clarify the relationship between HIF-1α and survival or clinicopathological features of bone tumor. PubMed, Cochrane Library, Web of Science, China National Knowledge Internet, and Wanfang databases were used to search the relationship between HIF-1α and bone tumor. Articles investigating clinicopathological and prognostic value of HIF-1α in bone tumor patients were enrolled in this meta-analysis. Overlapping articles, duplicate data, reviews, case reports, and letters without original data were excluded. The pooled risk ratios (RRs) and hazard ratios (HRs) were used to evaluate the clinicopathological and prognostic value of HIF-1α on bone tumor patients, respectively. A total of 28 studies including 1443 patients were included in this meta-analysis, which were involved in three different types of bone tumor including 3 chondrosarcomas, 2 giant cell tumors of bone, and 23 osteosarcomas. Our results showed that high expression levels of HIF-1α were associated with poorer OS (overall survival) (HR = 2.61, 95% CI 2.11–3.23, P < 0.001) and shorter DFS (disease-free survival) (HR = 2.02, 95% CI 1.41–2.89, P < 0.001) in bone tumor. In addition, this study also analyzed the role of HIF-1α expression in clinicopathological features, which were closely related with the severity of bone tumor, including differentiation, clinical stage, metastasis, and microvessel density. Our results indicated that HIF-1α overexpression was significantly associated with differentiation (RR = 1.56, 95% CI 1.00–2.43, P = 0.049), clinical stage (RR = 1.75, 95% CI 1.25–2.45, P = 0.001), metastasis (RR = 1.78, 95% CI 1.58–2.00, P < 0.001), and microvessel density (SMD = 2.34, 95% CI 1.35–3.34, P < 0.001) of bone tumor. HIF-1α overexpression indicated an unfavorable factor for OS and DFS in bone tumor, suggesting that HIF-1α may serve as a potential prognostic marker for bone tumor.

4 November 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
WXWei Xie
Wei Xie
HLHui Liu
Hui Liu
SCShufen Chen
Shufen Chen
WXWeizhen Xu
Weizhen Xu
WLWeibin Lin
Weibin Lin
JWJin Wu
Jin Wu
Background: To compare the biomechanical performance of three internal fixation constructs for AO/OTA 33-A3 distal femoral fractures. Methods: Thirty AO/OTA 33-A3 synthetic distal femoral fracture models were constructed and randomly divided into three groups. Group A (dual-plate construct) was fixed with a medial locking plate combined with a less invasive stabilization system (LISS). Group B was fixed with a retrograde femoral nail (RFN) combined with an LISS (RFN + LISS construct), and Group C was fixed with a retrograde tibial nail (RTN) combined with an LISS (RTN + LISS construct). The axial displacement, axial stiffness, torsional displacement, torsional stiffness and maximum failure load of different internal fixation constructs were recorded and statistically analyzed. Results: In the axial compression test, the average stiffness of Group C was significantly higher than that of Groups A and B, and the average displacement of Group C was significantly smaller than that of Groups A and B. In the torsion test, the torsion degree of Group C was significantly lower than that of Groups A and B, and Group C had a higher torsional stiffness than Groups A and B. In the axial compression failure test, the average ultimate load (a displacement greater than 5 mm) of Group C was significantly higher than that of Groups A and B. Conclusion: The biomechanical strength of the RTN combined with a plate is higher than that of the RFN combined with plate and dual-plate constructs, which can be used as an internal fixation option for the treatment of comminuted distal femoral fractures.

17 August 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
WXWei Xie
Wei Xie
DLDeqing Luo
Deqing Luo
LXLi Xie
Li Xie
LZLingqi Zhu
Lingqi Zhu
LZLiang Zhou
Liang Zhou
HLHui Liu
Hui Liu
Background Context: This study’s purpose was to evaluate the biomechanical performance of plate–nail and dual-plate fixation for the treatment of AO/OTA 41-C2 tibial plateau fractures. Methods: Twenty synthetic tibias were selected and randomly divided into a plate–nail group (n = 10) and a dual-plate group (n = 10). After the artificial tibias were osteotomized to simulate AO/OTA 41-C2 tibial plateau fractures in both groups, the plate–nail and the dual-plate methods, respectively, were used for fixation, and then axial compression loading, three-point bending, torsion, and axial failure tests were carried out. The data of each group were recorded and statistically analyzed. Results: In the axial compression test, the average stiffness of the plate–nail group was higher than that of the dual-plate group (p < 0.05). The displacement generated in the plate–nail group was significantly smaller than that in the dual-plate group (p < 0.05). In the resisting varus test, the stress of the plate–nail group was significantly higher than that of the dual-plate group (p < 0.05). In the resisting valgus test, the stress of the plate–nail group was slightly higher than that of the dual-plate group, but the difference was not statistically significant (p > 0.05). In the static torsion test, the load applied to the plate–nail group was smaller than that of the dual-plate group when rotated to 5° (p < 0.05). In the axial compression failure test, the average ultimate load of the plate–nail group was significantly higher than that of the dual-plate group (p < 0.05). Conclusion: The treatment of AO/OTA 41-C2 tibial plateau fractures with plate–nail fixation is superior to that with dual-plate fixation in resisting axial stress and preventing tibial varus deformity, while dual-plate fixation has better resisting torsional ability.

1 January 2021
Verified
Closed access
DLDeqing Luo
Deqing Luo
LYLe Yu
Le Yu
LYLimin Yang
Limin Yang
QZQigan Zhu
Qigan Zhu
HRHongyue Ren
Hongyue Ren
HLHui Liu
Hui Liu

27 October 2026 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
LXLi Xie
Li Xie
LZLingqi Zhu
Lingqi Zhu
JCJiewen Chen
Jiewen Chen
DLDeqing Luo
Deqing Luo
LZLiang Zhou
Liang Zhou
HLHui Liu
Hui Liu
To compare the biomechanical behaviour of four internal fixation strategies for AO/OTA type 41-C2 tibial plateau fractures using finite element analysis (F