Background: To compare the biomechanical performance of three internal fixation constructs for AO/OTA 33-A3 distal femoral fractures. Methods: Thirty AO/OTA 33-A3 synthetic distal femoral fracture models were constructed and randomly divided into three groups. Group A (dual-plate construct) was fixed with a medial locking plate combined with a less invasive stabilization system (LISS). Group B was fixed with a retrograde femoral nail (RFN) combined with an LISS (RFN + LISS construct), and Group C was fixed with a retrograde tibial nail (RTN) combined with an LISS (RTN + LISS construct). The axial displacement, axial stiffness, torsional displacement, torsional stiffness and maximum failure load of different internal fixation constructs were recorded and statistically analyzed. Results: In the axial compression test, the average stiffness of Group C was significantly higher than that of Groups A and B, and the average displacement of Group C was significantly smaller than that of Groups A and B. In the torsion test, the torsion degree of Group C was significantly lower than that of Groups A and B, and Group C had a higher torsional stiffness than Groups A and B. In the axial compression failure test, the average ultimate load (a displacement greater than 5 mm) of Group C was significantly higher than that of Groups A and B. Conclusion: The biomechanical strength of the RTN combined with a plate is higher than that of the RFN combined with plate and dual-plate constructs, which can be used as an internal fixation option for the treatment of comminuted distal femoral fractures.
Background Context: This study’s purpose was to evaluate the biomechanical performance of plate–nail and dual-plate fixation for the treatment of AO/OTA 41-C2 tibial plateau fractures. Methods: Twenty synthetic tibias were selected and randomly divided into a plate–nail group (n = 10) and a dual-plate group (n = 10). After the artificial tibias were osteotomized to simulate AO/OTA 41-C2 tibial plateau fractures in both groups, the plate–nail and the dual-plate methods, respectively, were used for fixation, and then axial compression loading, three-point bending, torsion, and axial failure tests were carried out. The data of each group were recorded and statistically analyzed. Results: In the axial compression test, the average stiffness of the plate–nail group was higher than that of the dual-plate group (p < 0.05). The displacement generated in the plate–nail group was significantly smaller than that in the dual-plate group (p < 0.05). In the resisting varus test, the stress of the plate–nail group was significantly higher than that of the dual-plate group (p < 0.05). In the resisting valgus test, the stress of the plate–nail group was slightly higher than that of the dual-plate group, but the difference was not statistically significant (p > 0.05). In the static torsion test, the load applied to the plate–nail group was smaller than that of the dual-plate group when rotated to 5° (p < 0.05). In the axial compression failure test, the average ultimate load of the plate–nail group was significantly higher than that of the dual-plate group (p < 0.05). Conclusion: The treatment of AO/OTA 41-C2 tibial plateau fractures with plate–nail fixation is superior to that with dual-plate fixation in resisting axial stress and preventing tibial varus deformity, while dual-plate fixation has better resisting torsional ability.
22 May 2025 in Frontiers in Bioengineering and Biotechnology
Objective: To investigate the biomechanical strength of cementless long-stem fixation for the treatment of periprosthetic clamshell fracture.Methods: Eighteen Sawbones artificial femur models were used and divided into three groups. Group A had an intact medial wall. Group B, the proximal periprosthetic femoral medial wall was osteotomized to simulate periprosthetic clamshell fractures. Group C, following identical osteotomy to Group B, cerclage wiring was applied to fix the medial wall fracture fragment. After molding, the cementless long-stem were implanted in all models, which were then evaluated through axial compression tests, torsion tests, and axial failure tests. The axial stiffness, axial displacement, torsional stiffness, torque, and maximum failure load were recorded and statistically analyzed.Results: In the axial compression tests, no statistically significant differences were observed among Groups A, B, and C in terms of axial displacement, axial stiffness, or maximum failure load (the displacement greater than 3 mm). However, in the torsional tests, Group B showed significantly lower torsional stiffness or torque compared to Groups A and C (p < 0.05). No significant differences in torsional stiffness or torque were detected between Groups A and C.Conclusion: The integrity of the femoral medial wall is crucial for femoral stem stability. In case of medial wall fracture, while cementless long-stem implantation can achieve satisfactory axial stability, its torsional stability remains inadequate. The application of supplemental cerclage wiring for medial wall fragment fixation provides reliable improvement in torsional stability of the stem.
Massive irreparable rotator cuff tears (MIRCTs) are not uncommon in clinical practice, significantly impacting shoulder function and daily activities. Extensive tear size, tendon contracture, and fat infiltration within the rotator cuff pose significant challenges for both patients and clinicians. This type of tear is a key area of interest and a challenge in research and treatments. Current treatment options include conservative management, debridement, partial repair, superior capsule reconstruction (SCR), tendon transfers, and reverse total shoulder arthroplasty (RTSA). However, clinical outcomes vary widely. The rotator cable (RC) exhibits a perpendicular orientation with respect to the superior rotator cuffs, thereby forming an arc-shaped attachment to the proximal humerus, and it plays an essential role in maintaining the rotator cuff's force couple. The attachments of both anterior and posterior RC play a crucial role in facilitating overhead movements. When complete tension-free coverage of the footprint cannot be attained, whole rotator cable reconstruction (WRCR) presents as an alternative approach for MIRCTs. We utilized autologous tendon harvested from the proximal biceps tendon for arthroscopic WRCR. The proposed technique offers distinct advantages: autologous tissue utilization eliminates immunogenicity; simplified harvesting reduces operative complexity; and minimized anchor usage enhances cost-effectiveness. In this study, 12 patients underwent WRCR, with significant improvements in shoulder function and pain relief observed during a 1 year follow-up.
Background. Platelet‐rich plasma (PRP) therapy is a new kind of biological therapy to retune the plasma concentrator into the patient’s body for the treatment of osteoarthritis diseases. The present research aimsed to confirm the treatment effects of PRP against osteoarthritis injury and elucidate its potential mechanism via constructing a kind of cellular injury model of human synovial fibroblast cells (HSF cells) induced by synovial fluid from osteoarthritis patients. Materials and Methods. HSF cells wereas firstly treated with the different doses of synovial fluid from osteoarthritis patients, and evaluated for the cellular injury via cell morphology and MTT assay. And then, the protective effect of PRP against cellular injury were examined by cell morphology and MTT assay. Following, flow cytometry and western blot assay were employed to evaluate the effect of PRP on mitochondrial apoptosis. Finally, the effect of PRP on NF‐κB pathway‐associated inflammation wasere examined by Elisa ELISA assay and western blot. Results. The dilution ratio 1 : 5 of synovial fluid displayed an excellent injury effect against HSF cells and selected as the model condition. The data from cellular image and MTT assay showed that PRP with the doses 1 : 5 and 1 : 10 could alleviate the cellular mounts decrease in the damaged HSF cells. Flow cytometry, western blot, and Elisa ELISA assay displayed that PRP could relieve the cellular mitochondrial apoptosis and NF‐κB pathway‐associated inflammation in the damaged HSF cells. Conclusion. PRP might relieve HSF cells injury induced by synovial fluid from osteoarthritis patients through alleviating the mitochondrial apoptosis and NF‐κB pathway‐associated inflammation.
To compare the biomechanical behaviour of four internal fixation strategies for AO/OTA type 41-C2 tibial plateau fractures using finite element analysis (F